2 research outputs found

    Pediatric Giant Right Atrial Aneurysm: A Case Series and Review of the Literature

    Full text link
    Giant right atrial aneurysm is a rare form of congenital heart disease with a wide spectrum of clinical presentation varying from asymptomatic patients to those with refractory atrial arrhythmias or severe airway obstruction. Diagnosis is often confused with other causes of right atrial dilation such as E bstein disease. Because of its rare occurrence and variable clinical presentation, inconsistencies in medical and surgical management strategies exist between centers. We present five cases of giant right atrial aneurysm managed at our institution and discuss the clinical presentation, diagnostic challenges, and medical and surgical management.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/107528/1/chd12079.pd

    Long-Term Follow Up of Secundum Atrial Septal Defect Closure with the Amplatzer Septal Occluder

    Full text link
    During the past 15 years, closure of a secundum atrial septal defect (ASD) has moved from a surgical to a percutaneous transcatheter approach. Few long-term studies of the efficacy and safety of closure of an ASD by an Amplatzer septal occluder (ASO) exist.To examine the long-term results of secundum ASD closure using the ASO, data on 94 patients who underwent secundum ASD closure with the ASO between 1998 and 2002 were available and reviewed. Data regarding residual shunt, chest pain, palpitations, arrhythmias, headaches, transient ischemic attacks, cerebrovascular accidents, and mortality were collected.Seven (7.4%) subjects had residual shunts immediately following ASO placement. During follow-up, 4 residual shunts closed for a complete closure rate of 97%. Eighteen (19%) patients reported chest pain during the follow-up period. Twenty-three patients (24%) reported palpitations during the follow up period, 7 were documented arrhythmias, including supraventricular tachycardia, atrial fibrillation, and premature ventricular beats. Migraine headaches were new-onset in 4 patients. Migraine cessation occurred in 2 patients after secundum ASD closure. One child died from a cerebral vascular event 18 months following device placement. Only 1 patient developed mild aortic insufficiency.These data indicate that for up to 120 months of patient follow-up, the ASO continues to be a safe device. Residual shunts and arrhythmias have low incidence post-ASO placement. Given the mortality in one high-risk patient, further investigation into anti-platelet therapy after device placement is warranted.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/78631/1/j.1747-0803.2009.00358.x.pd
    corecore