9 research outputs found

    Evaluation of Cortez Onestep Chlamydia RapicardTM Insta Test for the Detection of Chlamydia Trachomatis in Pregnant Women at Mbare Polyclinic in Harare, Zimbabwe

    Get PDF
    Background: Cervical chlamydia infection poses high risk of pregnancy complications and neonatal infection. Reference methods for the detection of chlamydia infection are not available for routine use in developing countries. Point-of-care (POC) tests can bridge this gap. This study evaluated Cortez Onestep Chlamydia RapicardTM insta test for the detection of Chlamydia trachomatis in pregnant women at Mbare Polyclinic and determined the prevalence of C. trachomatis. Methods: This was a cross sectional study in 242 pregnant women aged ≥18 years attending their first ANC visit at Mbare polyclinic in Harare, Zimbabwe. Data collection form was used to obtain demographic and predisposing factors to Chlamydia infection and two endocervical swabs were collected from each patient. One specimen was examined by the POC test at the clinic and the other by SDA method in the laboratory. Results: The sensitivity, specificity, positive and negative predictive values of the rapid kit were 71.4%, 99.6%, 90.9% and 98.3% respectively. Prevalence of C. trachomitis was 5.8% by SDA method. Conclusion and Global Health Implications: The kit’s sensitivity (71.4%) and specificity (99.6%) implies that the rapid test is an important test which needs further evaluations. The prevalence of C. trichomitis of 5.8% is comparable to studies done elsewhere in Africa. Key words: Chlamydia trachomatis • Antenatal Clinic • Point of Care Tests • Rapid Test • Cortez One Step Chlamydia Test Copyright © 2017 Stephen et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited

    Impact of second-line antiretroviral regimens on lipid profiles in an African setting: the DART trial sub-study

    No full text
    Background: Increasing numbers of HIV-infected patients in sub-Saharan Africa are exposed to antiretroviral therapy (ART), but there are few data on lipid changes on first-line ART, and even fewer on second-line.Methods: DART was a randomized trial comparing monitoring strategies in Ugandan/Zimbabwean adults initiating first-line ART and switching to second-line at clinical/immunological failure. We evaluated fasting lipid profiles at second-line initiation and ≥48 weeks subsequently in stored samples from Zimbabwean patients switching before 18 September 2006.Results: Of 91 patients switched to second-line ART, 65(73%) had fasting samples at switch and ≥48 weeks, 14(15%) died or were lost 14 days and 2(2%) had no samples available. 56/65(86%) received ZDV/d4T + 3TC + TDF first-line, 6(9%) ZDV/d4T + 3TC + NVP and 3(5%) ZDV + 3TC with TDF and NVP. Initial second-line regimens were LPV/r + NNRTI in 27(41%), LPV/r + NNRTI + ddI in 33(50%) and LPV/r + TDF + ddI/3TC/ZDV in 6(9%). At second-line initiation median (IQR) TC, LDL-C, HDL-C and TG (mmol/L) were 3.3(2.8-4.0), 1.7(1.3-2.2), 0.7(0.6-0.9) and 1.1(0.8-1.9) respectively. Levels were significantly increased 48 weeks later, by mean (SE) +2.0(0.1), +1.1(0.1), +0.5(0.05) and +0.4(0.2) respectively (p 5.2 mmol/L; 3% vs 25% LDL-C >3.4 mmol/L and 91% vs 41% HDL-C 1.8 mmol/L (0 vs 3%) and TC/HDL-C ≥5 (40% vs 33%) (p > 0.15).Conclusion: Modest lipid elevations were observed in African patients on predominantly LPV/r + NNRTI-based second-line regimens. Routine lipid monitoring during second-line ART regimens may not be warranted in this setting but individual cardiovascular risk assessment should guide practice

    Adult Hematology and Clinical Chemistry Laboratory Reference Ranges in a Zimbabwean Population.

    No full text
    Laboratory reference ranges used for clinical care and clinical trials in various laboratories in Zimbabwe were derived from textbooks and research studies conducted more than ten years ago. Periodic verification of these ranges is essential to track changes over time. The purpose of this study was to establish hematology and chemistry laboratory reference ranges using more rigorous methods.A community-based cross-sectional study was carried out in Harare, Chitungwiza, and Mutoko. A multistage sampling technique was used. Samples were transported from the field for analysis at the ISO15189 certified University of Zimbabwe-University of California San Francisco Central Research Laboratory. Hematology and clinical chemistry reference ranges lower and upper reference limits were estimated at the 2.5th and 97.5th percentiles respectively.A total of 769 adults (54% males) aged 18 to 55 years were included in the analysis. Median age was 28 [IQR: 23-35] years. Males had significantly higher red cell counts, hemoglobin, hematocrit, and mean corpuscular hemoglobin compared to females. Females had higher white cell counts, platelets, absolute neutrophil counts, and absolute lymphocyte counts compared to males. There were no gender differences in eosinophils, monocytes, and absolute basophil count. Males had significantly higher levels of urea, sodium, potassium, calcium, creatinine, amylase, total protein, albumin and liver enzymes levels compared to females. Females had higher cholesterol and lipase compared with males. There are notable differences in the white cell counts, neutrophils, cholesterol, and creatinine kinase when compared with the currently used reference ranges.Data from this study provides new country specific reference ranges which should be immediately adopted for routine clinical care and accurate monitoring of adverse events in research studies

    Impact of second-line antiretroviral regimens on lipid profiles in an African setting: the DART trial sub-study.

    No full text
    BACKGROUND: Increasing numbers of HIV-infected patients in sub-Saharan Africa are exposed to antiretroviral therapy (ART), but there are few data on lipid changes on first-line ART, and even fewer on second-line. METHODS: DART was a randomized trial comparing monitoring strategies in Ugandan/Zimbabwean adults initiating first-line ART and switching to second-line at clinical/immunological failure. We evaluated fasting lipid profiles at second-line initiation and ≥48 weeks subsequently in stored samples from Zimbabwean patients switching before 18 September 2006. RESULTS: Of 91 patients switched to second-line ART, 65(73%) had fasting samples at switch and ≥48 weeks, 14(15%) died or were lost <48 weeks, 10(11%) interrupted ART for >14 days and 2(2%) had no samples available. 56/65(86%) received ZDV/d4T + 3TC + TDF first-line, 6(9%) ZDV/d4T + 3TC + NVP and 3(5%) ZDV + 3TC with TDF and NVP. Initial second-line regimens were LPV/r + NNRTI in 27(41%), LPV/r + NNRTI + ddI in 33(50%) and LPV/r + TDF + ddI/3TC/ZDV in 6(9%). At second-line initiation median (IQR) TC, LDL-C, HDL-C and TG (mmol/L) were 3.3(2.8-4.0), 1.7(1.3-2.2), 0.7(0.6-0.9) and 1.1(0.8-1.9) respectively. Levels were significantly increased 48 weeks later, by mean (SE) +2.0(0.1), +1.1(0.1), +0.5(0.05) and +0.4(0.2) respectively (p < 0.001; TG p = 0.01). 3% at switch vs 25% 48 weeks later had TC >5.2 mmol/L; 3% vs 25% LDL-C >3.4 mmol/L and 91% vs 41% HDL-C <1.1 mmol/L (p < 0.001). Similar proportions had TG >1.8 mmol/L (0 vs 3%) and TC/HDL-C ≥5 (40% vs 33%) (p > 0.15). CONCLUSION: Modest lipid elevations were observed in African patients on predominantly LPV/r + NNRTI-based second-line regimens. Routine lipid monitoring during second-line ART regimens may not be warranted in this setting but individual cardiovascular risk assessment should guide practice

    Adult Hematology and Clinical Chemistry Laboratory Reference Ranges in a Zimbabwean Population

    No full text
    Laboratory reference ranges used for clinical care and clinical trials in various laboratories in Zimbabwe were derived from textbooks and research studies conducted more than ten years ago. Periodic verification of these ranges is essential to track changes over time. The purpose of this study was to establish hematology and chemistry laboratory reference ranges using more rigorous methods.A community-based cross-sectional study was carried out in Harare, Chitungwiza, and Mutoko. A multistage sampling technique was used. Samples were transported from the field for analysis at the ISO15189 certified University of Zimbabwe-University of California San Francisco Central Research Laboratory. Hematology and clinical chemistry reference ranges lower and upper reference limits were estimated at the 2.5th and 97.5th percentiles respectively.A total of 769 adults (54% males) aged 18 to 55 years were included in the analysis. Median age was 28 [IQR: 23-35] years. Males had significantly higher red cell counts, hemoglobin, hematocrit, and mean corpuscular hemoglobin compared to females. Females had higher white cell counts, platelets, absolute neutrophil counts, and absolute lymphocyte counts compared to males. There were no gender differences in eosinophils, monocytes, and absolute basophil count. Males had significantly higher levels of urea, sodium, potassium, calcium, creatinine, amylase, total protein, albumin and liver enzymes levels compared to females. Females had higher cholesterol and lipase compared with males. There are notable differences in the white cell counts, neutrophils, cholesterol, and creatinine kinase when compared with the currently used reference ranges.Data from this study provides new country specific reference ranges which should be immediately adopted for routine clinical care and accurate monitoring of adverse events in research studies
    corecore