2 research outputs found

    Study of quasimonoenergetic electron bunch generation in self-modulated laser wakefield acceleration using TW or sub-TW ultrashort laser pulses

    Get PDF
    This work presents a study on laser wakefield electron acceleration in the self-modulated regime (SM-LWFA) using 50-fs laser pulses with energy on the mJ scale, at λ = 0.8 µm, impinging on a thin H2 gas jet. Particle-in-cell simulations were performed using laser peak powers ranging from sub-terawatt to a few terawatts and plasma densities varying from the relativistic self-focusing threshold up to values close to the critical density. The differences in the obtained acceleration processes are discussed. Results show that bunched electron beams with full charge on the nC scale and kinetic energy in the MeV range can be produced and configurations with peak density in the range 0.5–5 × 1020 atoms/cm3 generate electrons with maximum energies. In this range, some simulations generated quasimonoenergetic bunches with ∼0.5% of the total accelerated charge and we show that the beam characteristics, process dynamics, and operational parameters are close to those expected for the blowout regime. The configurations that led to quasimonoenergetic bunches from the sub-TW SM-LWFA regime allow the use of laser systems with repetition rates in the kHz range, which can be beneficial for practical applications

    Postural Assessment Software (PAS/SAPO): Validation and Reliabiliy

    Get PDF
    OBJECTIVE: This study was designed to estimate the accuracy of the postural assessment software (PAS/SAPO) for measurement of corporal angles and distances as well as the inter- and intra-rater reliabilities. INTRODUCTION: Postural assessment software was developed as a subsidiary tool for postural assessment. It is easy to use and available in the public domain. Nonetheless, validation studies are lacking. METHODS: The study sample consisted of 88 pictures from 22 subjects, and each subject was assessed twice (1 week interval) by 5 blinded raters. Inter- and intra-rater reliabilities were estimated using the intraclass correlation coefficient. To estimate the accuracy of the software, an inanimate object was marked with hallmarks using pre-established parameters. Pictures of the object were rated, and values were checked against the known parameters. RESULTS: Inter-rater reliability was excellent for 41% of the variables and very good for 35%. Ten percent of the variables had acceptable reliability, and 14% were defined as non-acceptable. For intra-rater reliability, 44.8% of the measurements were considered to be excellent, 23.5% were very good, 12.4% were acceptable and 19.3% were considered non-acceptable. Angular measurements had a mean error analisys of 0.11°, and the mean error analisys for distance was 1.8 mm. DISCUSSION: Unacceptable intraclass correlation coefficient values typically used the vertical line as a reference, and this may have increased the inaccuracy of the estimates. Increased accuracies were obtained by younger raters with more sophisticated computer skills, suggesting that past experience influenced results. CONCLUSION: The postural assessment software was accurate for measuring corporal angles and distances and should be considered as a reliable tool for postural assessment
    corecore