1,630 research outputs found

    A large Venous-Arterial PCO2 Is Associated with Poor Outcomes in Surgical Patients

    Get PDF
    Background. This study evaluated whether large venous-arterial CO2 gap (PCO2 gap) preoperatively is associated to poor outcome. Method. Prospective study which included adult high-risk surgical patients. The patients were pooled into two groups: wide [P(v-a)CO2] versus narrow [P(v-a)CO2]. In order to determine the best value to discriminate hospital mortality, it was applied a ROC (receiver operating characteristic) curve for the [P(v-a)CO2] values collected preoperatively, and the most accurate value was chosen as cut-off to define the groups. Results. The study included 66 patients. The [P(v-a)CO2] value preoperatively that best discriminated hospital mortality was 5.0 mmHg, area = 0.73. Preoperative patients with [P(v-a)CO2] more than 5.0 mmHg presented a higher hospital mortality (36.4% versus 4.5% P = 0.004), higher prevalence of circulatory shock (56.8% versus 22.7% P = 0.01) and acute renal failure postoperatively (27.3% versus 4.5% P = 0.02), and longer hospital length of stays 20.0 (14.0–30.0) versus 13.5 (9.0–25.0) days P = 0.01. Conclusions. The PCO2 gap values more than 5.0 mmHg preoperatively were associated with worse postoperatively outcome

    Effects of cardiopulmonary bypass on propofol pharmacokinetics and bispectral index during coronary surgery

    Get PDF
    PURPOSE: Cardiopulmonary bypass is known to alter propofol pharmacokinetics in patients undergoing cardiac surgery. However, few studies have evaluated the impact of these alterations on postoperative pharmacodynamics. This study was designed to test the hypothesis that changes in propofol pharmacokinetics increase hypnotic effects after cardiopulmonary bypass. METHODS: Twenty patients scheduled for on-pump coronary artery bypass graft (group, n=10) or off-pump coronary artery bypass graft (group, n=10) coronary artery bypass grafts were anesthetized with sufentanil and a propofol target controlled infusion (2.0 µg/mL). Depth of hypnosis was monitored using the bispectral index. Blood samples were collected from the induction of anesthesia up to 12 hours after the end of propofol infusion, at predetermined intervals. Plasma propofol concentrations were measured using high-performance liquid chromatography, followed by a non-compartmental propofol pharmacokinetic analysis. Data were analyzed using ANOVA, considering p<0.05 as significant. RESULTS: After cardiopulmonary bypass, despite similar plasma propofol concentrations in both groups, bispectral index values were lower in the on-pump coronary artery bypass graft group. Time to extubation after the end of propofol infusion was greater in the on-pump coronary artery bypass graft group (334 ± 117 vs. 216 ± 85 min, p = 0.04). Patients undergoing cardiopulmonary bypass had shorter biological (1.82 ± 0.5 vs. 3.67 ± 1.15h, p < 0.01) and terminal elimination (6.27 ± 1.29 vs. 10.5h ± 2.18, p < 0.01) half-life values, as well as higher total plasma clearance (28.36 ± 11.40 vs.18.29 ± 7.67 mL/kg/min, p = 0.03), compared to patients in the off-pump coronary artery bypass graft group. CONCLUSION: Aside from the increased sensitivity of the brain to anesthetics after cardiopulmonary bypass, changes in propofol pharmacokinetics may contribute to its central nervous system effects

    Effects of contrast material on computed tomographic measurements of lung volumes in patients with acute lung injury

    Get PDF
    BACKGROUND: Intravenous injection of contrast material is routinely performed in order to differentiate nonaerated lung parenchyma from pleural effusion in critically ill patients undergoing thoracic computed tomography (CT). The aim of the present study was to evaluate the effects of contrast material on CT measurement of lung volumes in 14 patients with acute lung injury. METHOD: A spiral thoracic CT scan, consisting of contiguous axial sections of 10 mm thickness, was performed from the apex to the diaphragm at end-expiration both before and 30 s (group 1; n = 7) or 15 min (group 2; n = 7) after injection of 80 ml contrast material. Volumes of gas and tissue, and volumic distribution of CT attenuations were measured before and after injection using specially designed software (Lungview(®); Institut National des Télécommunications, Evry, France). The maximal artifactual increase in lung tissue resulting from a hypothetical leakage within the lung of the 80 ml contrast material was calculated. RESULTS: Injection of contrast material significantly increased the apparent volume of lung tissue by 83 ± 57 ml in group 1 and 102 ± 80 ml in group 2, whereas the corresponding maximal artifactual increases in lung tissue were 42 ± 52 ml and 31 ± 18 ml. CONCLUSION: Because systematic injection of contrast material increases the amount of extravascular lung water in patients with acute lung injury, it seems prudent to avoid this procedure in critically ill patients undergoing a thoracic CT scan and to reserve its use for specific indications

    The effect of excess fluid balance on the mortality rate of surgical patients: a multicenter prospective study

    Get PDF
    INTRODUCTION: In some studies including small populations of patients undergoing specific surgery, an intraoperative liberal infusion of fluids was associated with increasing morbidity when compared to restrictive strategies. Therefore, to evaluate the role of excessive fluid infusion in a general population with high-risk surgery is very important. The aim of this study was to evaluate the impact of intraoperative fluid balance on the postoperative organ dysfunction, infection and mortality rate. METHODS: We conducted a prospective cohort study during one year in four ICUs from three tertiary hospitals, which included patients aged 18 years or more who required postoperative ICU after undergoing major surgery. Patients who underwent palliative surgery and whose fluid balance could change in outcome were excluded. The calculation of fluid balance was based on preoperative fasting, insensible losses from surgeries and urine output minus fluid replacement intraoperatively. RESULTS: The study included 479 patients. Mean age was 61.2 ± 17.0 years and 8.8% of patients died at the hospital during the study. The median duration of surgery was 4.0 (3.2 to 5.5) h and the value of the Simplified Acute Physiology Score (SAPS) 3 score was 41.8 ± 14.5. Comparing survivors and non-survivors, the intraoperative fluid balance from non-survivors was higher (1,950 (1,400 to 3,400) mL vs. 1,400 (1,000 to 1,600) mL, P <0.001). Patients with fluid balance above 2,000 mL intraoperatively had a longer ICU stay (4.0 (3.0 to 8.0) vs. 3.0 (2.0 to 6.0), P <0.001) and higher incidence of infectious (41.9% vs. 25.9%, P = 0.001), neurological (46.2% vs. 13.2%, P <0.001), cardiovascular (63.2% vs. 39.6%, P <0.001) and respiratory complications (34.3% vs. 11.6%, P <0.001). In multivariate analysis, the fluid balance was an independent factor for death (OR per 100 mL = 1.024; P = 0.006; 95% CI 1.007 to 1.041). CONCLUSIONS: Patients with excessive intraoperative fluid balance have more ICU complications and higher hospital mortality

    The effect of excess fluid balance on the mortality rate of surgical patients: a multicenter prospective study

    Get PDF
    Introduction\ud In some studies including small populations of patients undergoing specific surgery, an intraoperative liberal infusion of fluids was associated with increasing morbidity when compared to restrictive strategies. Therefore, to evaluate the role of excessive fluid infusion in a general population with high-risk surgery is very important. The aim of this study was to evaluate the impact of intraoperative fluid balance on the postoperative organ dysfunction, infection and mortality rate.\ud \ud \ud Methods\ud We conducted a prospective cohort study during one year in four ICUs from three tertiary hospitals, which included patients aged 18 years or more who required postoperative ICU after undergoing major surgery. Patients who underwent palliative surgery and whose fluid balance could change in outcome were excluded. The calculation of fluid balance was based on preoperative fasting, insensible losses from surgeries and urine output minus fluid replacement intraoperatively.\ud \ud \ud Results\ud The study included 479 patients. Mean age was 61.2 ± 17.0 years and 8.8% of patients died at the hospital during the study. The median duration of surgery was 4.0 (3.2 to 5.5) h and the value of the Simplified Acute Physiology Score (SAPS) 3 score was 41.8 ± 14.5. Comparing survivors and non-survivors, the intraoperative fluid balance from non-survivors was higher (1,950 (1,400 to 3,400) mL vs. 1,400 (1,000 to 1,600) mL, P <0.001). Patients with fluid balance above 2,000 mL intraoperatively had a longer ICU stay (4.0 (3.0 to 8.0) vs. 3.0 (2.0 to 6.0), P <0.001) and higher incidence of infectious (41.9% vs. 25.9%, P = 0.001), neurological (46.2% vs. 13.2%, P <0.001), cardiovascular (63.2% vs. 39.6%, P <0.001) and respiratory complications (34.3% vs. 11.6%, P <0.001). In multivariate analysis, the fluid balance was an independent factor for death (OR per 100 mL = 1.024; P = 0.006; 95% CI 1.007 to 1.041).\ud \ud \ud Conclusions\ud Patients with excessive intraoperative fluid balance have more ICU complications and higher hospital mortality

    Measurement of differential cross sections for top quark pair production using the lepton plus jets final state in proton-proton collisions at 13 TeV

    Get PDF
    National Science Foundation (U.S.
    corecore