4,529 research outputs found

    Towards Loop Quantization of Plane Gravitational Waves

    Get PDF
    The polarized Gowdy model in terms of Ashtekar-Barbero variables is further reduced by including the Killing equations for plane-fronted parallel gravitational waves with parallel rays. The resulting constraint algebra, including one constraint derived from the Killing equations in addition to the standard ones of General Relativity, are shown to form a set of first-class constraints. Using earlier work by Banerjee and Date the constraints are expressed in terms of classical quantities that have an operator equivalent in Loop Quantum Gravity, making space-times with pp-waves accessible to loop quantization techniques.Comment: 14 page

    The activation energy for GaAs/AlGaAs interdiffusion

    Get PDF
    Copyright 1997 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. This article appeared in Journal of Applied Physics 82, 4842 (1997) and may be found at

    Dynamics of axialized laser-cooled ions in a Penning trap

    Full text link
    We report the experimental characterization of axialization - a method of reducing the magnetron motion of a small number of ions stored in a Penning trap. This is an important step in the investigation of the suitability of Penning traps for quantum information processing. The magnetron motion was coupled to the laser-cooled modified cyclotron motion by the application of a near-resonant oscillating quadrupole potential (the "axialization drive"). Measurement of cooling rates of the radial motions of the ions showed an order-of-magnitude increase in the damping rate of the magnetron motion with the axialization drive applied. The experimental results are in good qualitative agreement with a recent theoretical study. In particular, a classical avoided crossing was observed in the motional frequencies as the axialization drive frequency was swept through the optimum value, proving that axialization is indeed a resonant effect.Comment: 8 pages, 9 figure

    Amputee perception of prosthetic ankle stiffness during locomotion

    Full text link
    Abstract Background Prosthetic feet are spring-like, and their stiffness critically affects the wearer’s stability, comfort, and energetic cost of walking. Despite the importance of stiffness in ambulation, the prescription process often entails testing a limited number of prostheses, which may result in patients receiving a foot with suboptimal mechanics. To understand the resolution with which prostheses should be individually optimized, we sought to characterize below-knee prosthesis users’ psychophysical sensitivity to prosthesis stiffness. Methods We used a novel variable-stiffness ankle prosthesis to measure the repeatability of user-selected preferred stiffness, and implemented a psychophysical experiment to characterize the just noticeable difference of stiffness during locomotion. Results All eight subjects with below-knee amputation exhibited high repeatability in selecting their Preferred Stiffness (mean coefficient of variation: 14.2 ± 1.7%) and were able to correctly identify a 7.7 ± 1.3% change in ankle stiffness (with 75% accuracy). Conclusions This high sensitivity suggests prosthetic foot stiffness should be tuned with a high degree of precision on an individual basis. These results also highlight the need for a pairing of new robotic prescription tools and mechanical characterizations of prosthetic feet.https://deepblue.lib.umich.edu/bitstream/2027.42/146187/1/12984_2018_Article_432.pd

    Role of Various Types of Treatment in Infectious Hepatitis

    Get PDF

    About the dynamics and thermodynamics of trapped ions

    Full text link
    This tutorial introduces the dynamics of charged particles in a radiofrequency trap in a very general manner to point out the differences between the dynamics in a quadrupole and in a multipole trap. When dense samples are trapped, the dynamics is modified by the Coulomb repulsion between ions. To take into account this repulsion, we propose to use a method, originally developed for particles in Penning trap, that model the ion cloud as a cold fluid. This method can not reproduce the organisation of cold clouds as crystals but it allows one to scale the size of large samples with the trapping parameters and the number of ions trapped, for different linear geometries of trap.Comment: accepted for publication in the "Modern Applications of Trapped Ions" special issu

    Compact intense extreme-ultraviolet source

    Get PDF
    High-intensity laser pulses covering the ultraviolet to terahertz spectral regions are nowadays routinely generated in a large number of laboratories. In contrast, intense extreme-ultraviolet (XUV) pulses have only been demonstrated using a small number of sources including free-electron laser facilities and long high-harmonic generation (HHG) beamlines. Here, we demonstrate a concept for a compact intense XUV source based on HHG that is focused to an intensity of 2Ă—1014W/cm2, with a potential increase up to 1017W/cm2 in the future. Our approach uses tight focusing of the near-infrared (NIR) driving laser and minimizes the XUV virtual source size by generating harmonics several Rayleigh lengths away from the NIR focus. Accordingly, the XUV pulses can be refocused to a small beam waist radius of 600 nm, enabling the absorption of up to four XUV photons by a single Ar atom in a setup that fits on a modest (2 m) laser table. Our concept represents a straightforward approach for the generation of intense XUV pulses in many laboratories, providing exciting opportunities for XUV strong-field and nonlinear optics experiments, for XUV-pump XUV-probe spectroscopy and for the coherent diffractive imaging of nanoscale structures
    • …
    corecore