12 research outputs found

    Minimal Reporting Standards for Active Middle Ear Hearing Implants.

    Get PDF
    There is currently no standardized method for reporting audiological, surgical and subjective outcome measures in clinical trials with active middle ear implants (AMEIs). It is often difficult to compare studies due to data incompatibility and to perform meta-analyses across different centres is almost impossible. A committee of ENT and audiological experts from Germany, Austria and Switzerland decided to address this issue by developing new minimal standards for reporting the outcomes of AMEI clinical trials. The consensus presented here aims to provide a recommendation to enable better inter-study comparability

    Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events

    Get PDF
    BACKGROUND AND OBJECTIVE: The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. METHODS: A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. RESULTS: A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4–6.6%) of ETFO, 28.6% (26.6–30.6%) of ESD, and 0.53% (0.2–1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1–1.3%), 11% (9.2–13.0%), and 3.2% (2.5–3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. CONCLUSION: Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications

    Personalized Medicine in Otolaryngology: Special Topic Otology

    No full text
    Globally, more than 1.5 billion people experience some degree of hearing loss [...

    Improved Music Perception after Music Therapy following Cochlear Implantation in the Elderly Population

    No full text
    Background: Cochlear implantation (CI) and the accompanying rehabilitation has become a routine procedure in hearing restoration. Literature is sparse on elderly CI recipients focusing on the issue of age and their inclined auditory resolution, taking their diminished cognitive function into account, which requires adaptation of rehabilitation programs to overcome habituation. Objective: This study aims to show that a few adjustments in the therapy program towards age, mental, physical and auditory condition significantly improve music perception and overall auditory benefit, hence normal communication and social interactions can be found. Methods: Subjects implanted with a CI 65 years or older were compared to age-matched normal hearing subjects. Questionnaires were administered before and after ten music therapy sessions, to evaluate the participant’s music habits, the perception of sound quality and self-awareness and hearing implant satisfaction. Results: The greatest benefit was seen in participants’ gain in self-confidence and enjoyable music perception. Not only did the amount of listening to music increase, but also the impression of sound quality changed from poor up to good/very good sound quality. Conclusions: The music therapy was well accepted and resulted in beneficial subjective as well as objective outcomes towards hearing and music impression, hence improved quality of life

    Acute dyspnea caused by a giant spindle cell lipoma of the larynx

    No full text
    Lipomas are common benign mesenchymal neoplasms. Although 13% of lipomas are found in the head and neck, only 0.6% have been reported in the larynx. Of all lipomas, the spindle cell variant is the least common. In the present study, we report a case of supraglottic spindle cell lipoma and review the literature of laryngeal spindle cell lipoma. A 35-year-old male presented with dysphagia and dyspnea and was found to have bilateral supraglottic lesions causing airway obstruction. The masses were resected endoscopically. Final pathology demonstrated mature adipocytes and spindle cells, with immunohistochemical patterns supportive of spindle cell lipoma. Spindle cell lipomas have rarely been reported in the upper airway. To our knowledge, this is the youngest patient reported to date. These lipomas are uncommon benign neoplasms and should be distinguished from aggressive mesenchymal neoplasms such as liposarcoma variants to guide appropriate conservative but curative therapy

    Using generic and disease-specific measures to assess quality of life before and after 12 months of hearing implant use : a prospective, longitudinal, multicenter, observational clinical study

    No full text
    The primary objectives of this study were to evaluate the effect of hearing implant (HI) use on quality of life (QoL) and to determine which QoL measure(s) quantify QoL with greater sensitivity in users of different types of HIs. Participants were adult cochlear implant (CI), active middle ear implant (VIBRANT SOUNDBRIDGE (VSB)), or active transcutaneous bone conduction implant (the BONEBRIDGE (BB)) recipients. Generic QoL and disease-specific QoL were assessed at three intervals: pre-activation, 6 months of device use, and 12 months of device use. 169 participants completed the study (110 CI, 18VSB, and 41BB). CI users’ QoL significantly increased from 0–6 m device use on both the generic- and the disease-specific measures. On some device-specific measures, their QoL also significantly increased between 6 and 12 m device use. VSB users’ QoL significantly increased between all tested intervals with the disease-specific measure but not the generic measure. BB users’ QoL significantly increased from 0–6 m device use on both the generic- and the disease-specific measures. In sum, HI users experienced significant postoperative increases in QoL within their first 12 m of device use, especially when disease-specific measures were used. Disease-specific QoL measures appeared to be more sensitive than their generic counterparts

    Using Generic and Disease-Specific Measures to Assess Quality of Life before and after 12 Months of Hearing Implant Use: A Prospective, Longitudinal, Multicenter, Observational Clinical Study

    No full text
    The primary objectives of this study were to evaluate the effect of hearing implant (HI) use on quality of life (QoL) and to determine which QoL measure(s) quantify QoL with greater sensitivity in users of different types of HIs. Participants were adult cochlear implant (CI), active middle ear implant (VIBRANT SOUNDBRIDGE (VSB)), or active transcutaneous bone conduction implant (the BONEBRIDGE (BB)) recipients. Generic QoL and disease-specific QoL were assessed at three intervals: pre-activation, 6 months of device use, and 12 months of device use. 169 participants completed the study (110 CI, 18VSB, and 41BB). CI users&rsquo; QoL significantly increased from 0&ndash;6 m device use on both the generic- and the disease-specific measures. On some device-specific measures, their QoL also significantly increased between 6 and 12 m device use. VSB users&rsquo; QoL significantly increased between all tested intervals with the disease-specific measure but not the generic measure. BB users&rsquo; QoL significantly increased from 0&ndash;6 m device use on both the generic- and the disease-specific measures. In sum, HI users experienced significant postoperative increases in QoL within their first 12 m of device use, especially when disease-specific measures were used. Disease-specific QoL measures appeared to be more sensitive than their generic counterparts
    corecore