14 research outputs found

    Fitting hearing aid in patients candidate for cochlear implants

    Get PDF
    PURPOSE: to characterize the audiometric and demographic profile of cochlear implant candidates who were referred to hearing aid sector, and if they benefit from the amplification of the hearing aid. METHODS: patients who had been attended from May 2007 to December 2008 were studied. We collected the patients' profile involving: gender, age, education and etiology. The hearing threshold's average for the good and worse ears was calculated and classified according to Frota (2003). The averaged sound field thresholds with hearing aid was calculated for both ears and considered as a benefit when allowed for an access to the speech sounds of Brazilian Portuguese. RESULTS: a hundred and ninety-four medical records were evaluated in this period. Among them, 108 patients had already been wearing hearing aids (55.6%), 100 were male (52%), 94 female (48%), 109 were children (56%) and 85 adults (44%). The average age was 4.8year old for children and 41.9-year old for adults. Among the adults, 24 patients had incomplete high school education (33%). Unknown etiology was the most frequent cause (33%). Nineteen patients have benefited from the use of hearing aids (10%). The averaged sound field thresholds with hearing aid was 47 dBHL and 48 dBHL, in best and worse ears, respectively, for children, and 50 dBHL and 45 dBHL, respectively, for adults. CONCLUSIONS: the profile of the patients was: majority of children, males, unknown etiology, previously hearing aid users, average of age 4.8-year old for children and 41.9 for adults. Pure tone thresholds revealed profound bilateral hearing loss. About 10% of patients were benefited with the use of hearing aids.OBJETIVO: caracterizar o perfil audiométrico e demográfico de pacientes candidatos ao implante coclear encaminhados ao setor de prótese auditiva e entre esses, a frequência de indivíduos que se beneficiaram da amplificação sonora. MÉTODOS: foram estudados os pacientes atendidos no período de maio de 2007 a dezembro 2008. Foi realizado o levantamento do perfil da população segundo sexo, idade, escolaridade e etiologia. Foi calculada a média da melhor e pior orelha e classificada segundo Frota (2003). A média dos limiares auditivos com as próteses auditivas indicadas foi calculada e considerada como benefício quando permitia acesso aos sons da fala do português brasileiro (Russo e Behlau, 1993). RESULTADOS: foram avaliados nesse período 194 prontuários. 108 pacientes já eram usuários de próteses auditivas (55,6%), 100 do sexo masculino (52%), 94 do sexo feminino (48%), 109 eram crianças (56%) e 85 eram adultos (44%). A média de idade foi 4,8 anos (crianças) e 41,9 anos (adultos). Entre os adultos, 24 possuíam ensino fundamental incompleto (33%). A etiologia mais frequente foi a desconhecida (33%). Dezenove pacientes se beneficiaram do uso da prótese auditiva (10%). No grupo de pacientes que se beneficiaram da prótese auditiva, a média dos limiares em campo livre com amplificação foi de 47 dBNA e 48 dBNA, na melhor e na pior orelha, respectivamente, nas crianças e 50 dBNA e 45 dBNA, respectivamente, nos adultos. CONCLUSÃO: o perfil dos pacientes foi: na maioria criança, sexo masculino, etiologia desconhecida, já usuários de próteses auditivas com média de idade 4,8 anos (crianças) e 41,9 anos (adultos), audiometria com perda auditiva neurossensorial profunda bilateral, sendo que a prótese beneficiou 10% dos pacientes.Universidade de São PauloUniversidade Federal de São Paulo (UNIFESP)Universidade de São Paulo Faculdade de Medicina Hospital das ClínicasUNIFESPSciEL

    As manifestações clínicas do portador de paralisia facial

    Get PDF
    Introdução: A paralisia facial e um sintoma de um transtorno de base resultante em imobilidade e incapacidade de executar a mímica facial e a expressão emotiva. São várias as etiologias deste acometimento, sendo a classificação em paralisia facial periférica, representada classicamente pela paralisia de Bell e a central, pelo acidente vascular encefálico, adotada para auxiliar na investigação e seguimento clínico adequado. Objetivo: Descrever sobre a paralisia facial, com foco em características clínicas que propiciem ao diagnóstico precoce, medidas terapêuticas e restauração imediata. Metodologia: Revisão narrativa que selecionou artigos disponibilizados na íntegra publicados no recorte temporal de 2008 até 2022. Resultados: Dos 10 artigos incluídos neste estudo, todos realizaram uma ampla análise sobre a temática, a qual propiciou a disseminação de informações atualizadas sobre conceito, diagnóstico diferencial entre duas condições clínicas opostas resultantes em paralisia facial, manifestações, avaliação clínica e manejo adequado. Conclusão: Estudos ainda urgem em ser feitos no intuito de orientar melhor os profissionais e a comunidade a respeito da paralisia facial e a importância que possui o acompanhamento e seguimento precoce. Destarte,

    Contribution of the technological advance of the speech processor to patients with Nucleus 22®

    No full text
    Objetivo: Identificar as contribuições tecnológicas do processador de fala Freedom® para pacientes implantados com Nucleus 22® e a satisfação dos usuários com a nova tecnologia. Entre os novos recursos disponíveis, foram analisados o efeito da tabela de alocação de frequências, o T-SPL e C-SPL e o ajuste de pré-processamento do som (ADRO®). Material: Este estudo foi prospectivo e exploratório. Foram incluídos adolescentes e adultos implantados com Nucleus 22® no Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, usuários efetivos do processador de fala Spectra®, com alguma percepção de frases em contexto fechado e sem experiência anterior com a nova tecnologia. Foram selecionados 17 pacientes, entre as idades de 15 e 82 anos, e implantados há mais de oito anos. Para determinar a contribuição do Freedom®, os limiares auditivos e os testes de percepção de fala foram realizados com o último mapa utilizado com o Spectra® e comparados os mapas criados com o Freedom®. Para identificar o efeito da tabela de alocação de frequências, ambos os mapas convertidos (mesma tabela) e atualizados (tabela nova) foram programados. A tabela escolhida foi mantida, e foram realizados três mapas com diferentes parâmetros: o programa 1 (P1) com T-SPL de 30 dB e do C-SPL de 70 dB, programa 2 (P2) com T-SPL de 25 dB e do C-SPL de 65 dB, e o programa 3 (P3) com ADRO®. A ordem de apresentação dos mapas e dos testes foi randomizada. Para avaliar a satisfação com seus dispositivos auditivos foram utilizados os questionários SADL e APHAB após um mês e um ano de uso do Freedom®. Resultados: A contribuição do processador de fala Freedom® para pacientes usuários do Nucleus 22® foi estatisticamente superior em comparação com o Spectra® em todos os testes de percepção da fala e em todos os limiares audiométricos, tanto individualmente quanto em média, com exceção de 8000 Hz. Em relação à escolha da tabela de frequência, 64,7% dos pacientes (n=11) mantiveram o mapa com a tabela de frequências do Spectra®. Comparando os mapas com diferentes T-SPL e C-SPL, houve diferença estatística tanto nos limiares audiométricos de 500, 1000, 1500 e 2000 Hz quanto na média. Não houve diferença estatística entre os testes de fala com ou sem o uso do ADRO®. Os questionários de satisfação mostraram uma melhora estatisticamente significativa, apenas na subescala que avalia o desempenho em ambiente ruidoso e uso do telefone. Conclusão: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®. A maioria manteve a tabela de frequência original. As mudanças nos parâmetros de T-SPL e C-SPL mostraram uma melhora dos limiares audiométricos nas frequências principais da fala. As diferenças significantes foram sutis nos questionários de satisfação, demonstrando que os pacientes já estavam adaptados e satisfeitos com o implante coclearObjective: To identify the technological contributions of the Freedom® speech processor to the patients implanted with Nucleus 22® and the satisfaction of users of the new technology. Among the new features available, we focused on the effect of the frequency allocation table, the T-SPL and C-SPL and the pre-processing gain adjustments (ADRO®). Methods: This study was prospective and exploratory. It included teenage and adult patients implanted with Nucleus 22® who effectively used the implant with no previous experience with the new technology and had at least some speech recognition on a closed set with the Spectra® processor. Seventeen patients met the inclusion criteria, ranging in age from 15 to 82 years and deployed for over 8 years. To determine the contribution of the Freedom®, thresholds and speech perception tests were performed with the last map used with the Spectra® and the maps created for Freedom®. To identify the effect of the frequency allocation table, both converted (same table) and upgraded (new table) maps were programmed. The table selected is maintained, and maps were performed with three different parameters: the first program (P1) was programmed with 30 dB T-SPL and 70 dB C-SPL; the second program (P2) with was programmed with 25 dB T-SPL and 65 dB C-SPL; and the program 3 (P3) with ADRO®. The order of presentation of the maps and the testing was randomized. To assess satisfaction were used SADL and APHAB after one moth and one year of using the Freedom®. Results: The contribution of the Freedom® speech processor to patients with the Nucleus 22® was statistically superior compared to the Spectra® in all tests of speech perception and in all audiometric thresholds, both individually and on average, except for 8000 Hz. Regarding the choice of a frequency allocation table, 64.7% of patients (n=11) maintained the same map that had been used with the Spectra® processor. The sound field threshold was statistically significant at 500, 1000, 1500 and 2000 Hz with 25 dB T-SPL/ 65 dB C-SPL. The patients\' satisfaction there was a statistically significant improvement, only in the sub-scale of speech in noise abilities and telephone use. Conclusions: The Freedom® technology improved the performance of patients with the Nucleus 22®. Most of the patients retained the original frequency table. The changes in the parameters of T-SPL and C-SPL showed an improvement in the audiometric thresholds for the main frequencies of speech. Significant differences were subtle in questionnaires of satisfaction, demonstrating that patients were already adapted and satisfied with the cochlear implan

    Residual Hearing Preservation with the Evo® Cochlear Implant Electrode Array: Preliminary Results

    No full text
    Introduction The preservation of residual hearing is currently an important challenge for cochlear implant surgeries. Indeed, if patients exhibit functional hearing after cochlear implantation, they can benefit from the combination of acoustical stimulation, usually in the low-frequencies and electrical stimulation in the high-frequencies. This combined mode of stimulation has proven to be beneficial both in terms of speech perception and of sound quality. Finding the right procedures for conducting soft-surgeries and designing electrode arrays dedicated to hearing preservation is an open issue. Objective The objective of this study is to evaluate the combination of a soft-surgery procedure implicating round-window insertion and the use of dexamethasone and hyaluronic acid during surgery, with the use of a specifically designed straight soft electrode array, on hearing preservation in patients with functional hearing in the low frequencies. Methods This pre-clinical trial was conducted on seven patients with residual hearing in the low frequencies. The surgical method used employed a round window insertion and the use of topical dexamethasone. Results The soft-surgery protocol could be successfully followed in five patients. In this group, the average hearing threshold shift compared with pre-operative values was of 18.7 +/− 16.1 dB HL up to 500 Hz and 15.7 +/− 15.1 up to 1 kHz, demonstrating satisfying levels of hearing preservation. Conclusion We were able to demonstrate the possibility of preserving residual hearing in most of the patients using the EVO electrode. Significant residual hearing preservation levels were was obtained when a soft surgical approach involving round window insertion, dexamethasone and hyaluronic use during the surgery

    Ética da pesquisa em modelos animais Research ethics in animal models

    Get PDF
    A utilização de animais em experimentos científicos é descrita desde o século V a.C. Avanços científicos na área da saúde são atribuídos a modelos animais. O status moral dos animais sempre foi debatido. OBJETIVOS: Este artigo visa à revisão histórica e resumo da legislação atual, para orientar pesquisadores ao utilizar modelos animais na pesquisa em otorrinolaringologia. MATERIAL E MÉTODOS: Pesquisa na base de dados Medline. RESULTADOS: no Brasil, por muitos anos não havia regulamentação para o uso de animais em experimentação. Eram seguidas normas de organizações nacionais e internacionais. Recentemente, foi sancionada a lei nº 11.794/08, que estabelece procedimentos para o uso científico de animais. Na otorrinolaringologia, os estudos com laringe utilizaram coelho, porco, cachorro, cobaias (Cavia porcellus) e camundongo; estudos para face coelho, rato e cachorro; rinoplastia com coelho; e orelha interna com ratos e cobaias (albinas). CONCLUSÕES: Os pesquisadores envolvidos em trabalhos científicos com animais devem conhecer os princípios da lei nº 11.794/08 e pesquisar quais animais são apropriados para cada subárea estudada seus modelos com maior aplicabilidade. Os otorrinolaringologistas, especialmente aqueles que se dedicam à pesquisa, necessitam estar sempre atentos para o respeito às regras éticas de utilização de animais em seus estudos.<br>The use of animals in scientific experiments has beendescribed since the fifth century BC. A number of scientific advances in health are attributed to animal models. The issue of the moral status of animals has always been debated. OBJECTIVES: This article aims to review and to present a historical summary of the current laws, to guide researchers who wish to use animal models in otolaryngology research. MATERIAL AND METHODS: Research on the medline database. RESULTS: For many years there were no laws ruling the use of animals in scientific experimentation in Brazil. Standards set by national and international organizations were followed. Recently, Law No. 11.794/08 established procedures for the scientific use of animals. Studies in otolaryngology have used the larynxes of rabbits, pigs, dogs, guinea pigs (Cavia porcellus), and mice. There were also studies comparing rabbits, rats, and dogs, rhinoplasty on rabbits, and inner ear studies on rats and guinea pigs (albino). CONCLUSIONS: The researchers involved in scientific work with animals should know the principles of Law 11.794/08 and investigate what animals are appropriate for each area of study in their models. Otolaryngologists, especially those dedicated to research, need to be mindful of the ethical rules regarding the use of animals in their studies

    Resultados na percepção de fala após conversão do Spectra® para Freedom® Result on speech perception after conversion from Spectra® to Freedom®

    Get PDF
    As novas tecnologias do processador Freedom® foram criadas para proporcionar melhorias no processamento do som acústico de entrada, não apenas para novos usuários, como para gerações anteriores de implante coclear. OBJETIVO: Identificar a contribuição da tecnologia do processador de fala Freedom® para implante coclear multicanal, Nucleus22®, no desempenho de percepção de fala no silêncio e no ruído, e nos limiares audiométricos. MATERIAL E MÉTODO: A forma de estudo foi de coorte histórico com corte transversal. Dezessete pacientes preencheram os critérios de inclusão. Antes de iniciar os testes, o último mapa em uso com o Spectra® foi revisto e otimizado e o funcionamento do processador foi verificado. Os testes de fala foram apresentados a 60dBNPS em material gravado: monossílabos; frases em apresentação aberta no silêncio; e no ruído (SNR = 0dB). Foram realizadas audiometrias em campo livre com ambos os processadores de fala. A análise estatística utilizou testes não-paramétricos. RESULTADOS: Quando analisada a contribuição do Freedom® para pacientes com Nucleus22®, observa-se diferença estatisticamente significativa em todos os testes de percepção de fala e em todos os limiares audiométricos. CONCLUSÃO: A tecnologia contribuiu no desempenho de percepção de fala e nos limiares audiométricos dos pacientes usuários de Nucleus22®.<br>New technology in the Freedom® speech processor for cochlear implants was developed to improve how incoming acoustic sound is processed; this applies not only for new users, but also for previous generations of cochlear implants. AIM: To identify the contribution of this technology - the Nucleus 22® - on speech perception tests in silence and in noise, and on audiometric thresholds. METHODS: A cross-sectional cohort study was undertaken. Seventeen patients were selected. The last map based on the Spectra® was revised and optimized before starting the tests. Troubleshooting was used to identify malfunction. To identify the contribution of the Freedom® technology for the Nucleus22®, auditory thresholds and speech perception tests were performed in free field in sound-proof booths. Recorded monosyllables and sentences in silence and in noise (SNR = 0dB) were presented at 60 dBSPL. The nonparametric Wilcoxon test for paired data was used to compare groups. RESULTS: Freedom® applied for the Nucleus22® showed a statistically significant difference in all speech perception tests and audiometric thresholds. CONCLUSION: The reedom® technology improved the performance of speech perception and audiometric thresholds of patients with Nucleus 22®

    Adaptação de próteses auditivas no candidato ao implante coclear Fitting hearing aid in patients candidate for cochlear implants

    No full text
    OBJETIVO: caracterizar o perfil audiométrico e demográfico de pacientes candidatos ao implante coclear encaminhados ao setor de prótese auditiva e entre esses, a frequência de indivíduos que se beneficiaram da amplificação sonora. MÉTODOS: foram estudados os pacientes atendidos no período de maio de 2007 a dezembro 2008. Foi realizado o levantamento do perfil da população segundo sexo, idade, escolaridade e etiologia. Foi calculada a média da melhor e pior orelha e classificada segundo Frota (2003). A média dos limiares auditivos com as próteses auditivas indicadas foi calculada e considerada como benefício quando permitia acesso aos sons da fala do português brasileiro (Russo e Behlau, 1993). RESULTADOS: foram avaliados nesse período 194 prontuários. 108 pacientes já eram usuários de próteses auditivas (55,6%), 100 do sexo masculino (52%), 94 do sexo feminino (48%), 109 eram crianças (56%) e 85 eram adultos (44%). A média de idade foi 4,8 anos (crianças) e 41,9 anos (adultos). Entre os adultos, 24 possuíam ensino fundamental incompleto (33%). A etiologia mais frequente foi a desconhecida (33%). Dezenove pacientes se beneficiaram do uso da prótese auditiva (10%). No grupo de pacientes que se beneficiaram da prótese auditiva, a média dos limiares em campo livre com amplificação foi de 47 dBNA e 48 dBNA, na melhor e na pior orelha, respectivamente, nas crianças e 50 dBNA e 45 dBNA, respectivamente, nos adultos. CONCLUSÃO: o perfil dos pacientes foi: na maioria criança, sexo masculino, etiologia desconhecida, já usuários de próteses auditivas com média de idade 4,8 anos (crianças) e 41,9 anos (adultos), audiometria com perda auditiva neurossensorial profunda bilateral, sendo que a prótese beneficiou 10% dos pacientes.<br>PURPOSE: to characterize the audiometric and demographic profile of cochlear implant candidates who were referred to hearing aid sector, and if they benefit from the amplification of the hearing aid. METHODS: patients who had been attended from May 2007 to December 2008 were studied. We collected the patients' profile involving: gender, age, education and etiology. The hearing threshold's average for the good and worse ears was calculated and classified according to Frota (2003). The averaged sound field thresholds with hearing aid was calculated for both ears and considered as a benefit when allowed for an access to the speech sounds of Brazilian Portuguese. RESULTS: a hundred and ninety-four medical records were evaluated in this period. Among them, 108 patients had already been wearing hearing aids (55.6%), 100 were male (52%), 94 female (48%), 109 were children (56%) and 85 adults (44%). The average age was 4.8year old for children and 41.9-year old for adults. Among the adults, 24 patients had incomplete high school education (33%). Unknown etiology was the most frequent cause (33%). Nineteen patients have benefited from the use of hearing aids (10%). The averaged sound field thresholds with hearing aid was 47 dBHL and 48 dBHL, in best and worse ears, respectively, for children, and 50 dBHL and 45 dBHL, respectively, for adults. CONCLUSIONS: the profile of the patients was: majority of children, males, unknown etiology, previously hearing aid users, average of age 4.8-year old for children and 41.9 for adults. Pure tone thresholds revealed profound bilateral hearing loss. About 10% of patients were benefited with the use of hearing aids

    Satisfação e qualidade de vida em usuários de implante auditivo de tronco cerebral

    No full text
    RESUMO Objetivo Avaliar a satisfação e qualidade de vida em usuários de Implante Auditivo de Tronco Cerebral. Método Trata-se de um estudo transversal e descritivo realizado na Divisão de Clínica Otorrinolaringológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, Brasil. Para a realização da pesquisa, 19 usuários de implante auditivo de tronco cerebral responderam aos seguintes questionários: KINDLR (Questionnaire for Measuring Health-Related Quality of Life in Children and Adolescents) para crianças e adolescentes, pais e/ou cuidadores; o questionário WHOQOL-BREF para os participantes adultos; e o questionário SADL (Satisfaction with Amplification in Daily Life), adaptado culturalmente para o português brasileiro. Resultados A qualidade de vida das crianças usuárias de implante auditivo de tronco cerebral do ponto de vista dos pais apresentou resultados acima da média para o resultado global e para a maioria dos domínios, exceto o domínio de bem-estar emocional. Os adultos apresentaram resultados acima da média para todos os domínios. Com relação à satisfação com o dispositivo, os adultos usuários de implante auditivo de tronco cerebral estavam satisfeitos de modo geral, exceto no que diz respeito à imagem pessoal, e os pais das crianças mostraram insatisfação para todas as subescalas, exceto para a subescala de serviços e custos. Conclusão Os resultados indicaram que, apesar de os pacientes estarem insatisfeitos em alguns aspectos com o dispositivo, de modo geral, a qualidade de vida foi classificada como boa, para a maioria dos aspectos avaliados
    corecore