5 research outputs found

    Paclitaxel/methotrexate co-loaded PLGA nanoparticles in glioblastoma treatment: Formulation development and in vitro antitumor activity evaluation

    Get PDF
    AimThe aim of this study was to improve the therapeutic index of chemotherapeutic drugs on glioblastoma cells through an improved co-drug delivery system. Materials and methodsMethotrexate (MTX) and paclitaxel (PTX) were co-loaded into poly (lactic-co-glycolic acid) nanoparticles (PLGA NPs) coated with polyvinyl alcohol (PVA) and Poloxamer188 (P188). Key findingsThe mean size of the NPs was about 212 nm, with a zeta potential of about −15.7 mV. Encapsulation efficiency (EE%) and drug loading (DL%) were determined to be 72% and 4% for MTX and 85% and 4.9% for PTX, respectively. The prepared NPs were characterized by differential thermal analysis (DTA) and thermogravimetric analysis (TGA). Moreover, an in vitro sustained release profile was observed for both drug loaded PLGA NPs. Glioblastoma cellular uptake of the NPs was confirmed by fluorescence microscopy and cell survival rate was investigated through the 3-(4,5-dimethyl thiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) method after 48 h of incubation showing IC50 values of 24.5 μg·mL−1 for PTX and 9.5 μg·mL−1 for MTX for the MTX/PTX co-loaded PLGA nanoparticles coated with PVA/P188 (Co-2 NPs). Apoptosis and necrosis were also studied via flow cytometry, the lactate dehydrogenase (LDH) assay and the amount of anti-apoptotic protein (Bcl-2) expression. Blood compatibility of the co-delivery of PTX and MTX loaded PLGA NPs was investigated using a hemolysis method as well. SignificanceThe co-delivery of PTX and MTX loaded PLGA NPs is promising for the treatment of glioblastoma compared to their respective free drug formulations and, thus, should be further investigated.This work was supported by Tehran University of Medical Sciences, Grant No. 96-01-87-34138, Iran

    Contributions expérimentales sur la dynamique instationnaire de bulles de Taylor

    No full text
    The present work deals with the motion of a Taylor bubble rising through vertical oscillating pipes. The aim is to perform a more detailed and experimental quantitative study of this unsteady flow, still seldom addressed in the literature. The investigation is restricted to high Reynolds numbers to understand inertia effects. Experimental results are provided for two different configurations : 1) pipes with two different inner diameters (9.8 mm and 20 mm) filled with water, 2) the thinner pipe (D=9.8 mm) filled with four low viscous fluids. So the Bond number Bo, based on the steady rise velocity varies from 13 to 57, where the effects of surface tension can be considered. The bubble trajectory is tracked by using a high-speed video camera. The average terminal and fluctuating velocity, as well as the phase shift with the oscillating plate are obtained by using image processing. The main results show that for weak acceleration, the mean velocity decreases with the relative acceleration as the fluctuating velocity increases in proportion to this acceleration. Beyond a critical relative acceleration, the average velocity increases and the fluctuating velocity increase seems to slow down. This behavior change seems to be related to the interface deformation (modified curvature, surface waves) which becomes significant in high accelerations. Additionally, comparisons are made with the numerical results obtained by neglecting the capillary effects. Correlations allowing the prediction of mean and fluctuating velocities depending on the Bond number and relative acceleration are proposed and compared with our experimental results. The time evolution of the radii of curvature in the vicinity of the bubble nose is also studied for different relative accelerations and the results are compared with the stagnant case. In high accelerations, the formation and propagation of surface waves which may influence the bubble dynamics are quantifiedCette étude porte sur la dynamique instationnaire d'une bulle de Taylor dans un tube vertical en repère oscillant. L'objectif est de réaliser une étude expérimentale quantitative plus détaillée de cet écoulement instationnaire, très peu abordé dans la littérature. Les résultats expérimentaux sont obtenus pour des grands nombres de Reynolds pour comprendre les effets d'inertie. Deux configurations différentes sont étudiées : 1) tubes avec deux diamètres internes différents (9,8 mm et 20 mm) remplis d'eau, 2) le tube de diamètre D=9,8 mm rempli de quatre fluides peu visqueux. Le nombre de Bond Bo, basé sur la vitesse ascendante en cas stagnant, varie alors entre 13 et 57, où les effets de la tension superficielle peuvent être pris en compte. La bulle est suivie à l'aide d'une caméra rapide. les vitesses moyenne et fluctuante et le déphasage avec le plateau oscillant sont obtenus par traitement d'images et traitement numérique des données. Les résultats principaux montrent que pour les faibles accélérations la vitesse moyenne diminue et la vitesse fluctuante augmente lorsque l'accélération relative augmente. Au delà d'une accélération critique, la vitesse moyenne augmente et l'augmentation de la vitesse fluctuante semble ralentir. Ce changement de comportement semble être lié à la déformation de l'interface (courbure modifiée, ondes de surface) qui devient significative aux accélérations élevées. De plus, les comparaisons avec les résultats numériques obtenus en négligeant les effets capillaires sont effectuées. Des corrélations permettant de calculer les vitesses moyenne et fluctuante sont proposées. L'évolution temporelle de rayon de courbure au voisinage du nez de la poche est également étudiée pour les différentes accélérations et les résultats sont comparés avec le cas stagnant. Pour les accélérations élevées, la formation et la propagation des ondes oscillantes qui affectent la dynamique de l'écoulement sont quantifiée

    Experimental contributions on the unsteady dynamics of Taylor bubbles

    No full text
    Cette étude porte sur la dynamique instationnaire d'une bulle de Taylor dans un tube vertical en repère oscillant. L'objectif est de réaliser une étude expérimentale quantitative plus détaillée de cet écoulement instationnaire, très peu abordé dans la littérature. Les résultats expérimentaux sont obtenus pour des grands nombres de Reynolds pour comprendre les effets d'inertie. Deux configurations différentes sont étudiées : 1) tubes avec deux diamètres internes différents (9,8 mm et 20 mm) remplis d'eau, 2) le tube de diamètre D=9,8 mm rempli de quatre fluides peu visqueux. Le nombre de Bond Bo, basé sur la vitesse ascendante en cas stagnant, varie alors entre 13 et 57, où les effets de la tension superficielle peuvent être pris en compte. La bulle est suivie à l'aide d'une caméra rapide. les vitesses moyenne et fluctuante et le déphasage avec le plateau oscillant sont obtenus par traitement d'images et traitement numérique des données. Les résultats principaux montrent que pour les faibles accélérations la vitesse moyenne diminue et la vitesse fluctuante augmente lorsque l'accélération relative augmente. Au delà d'une accélération critique, la vitesse moyenne augmente et l'augmentation de la vitesse fluctuante semble ralentir. Ce changement de comportement semble être lié à la déformation de l'interface (courbure modifiée, ondes de surface) qui devient significative aux accélérations élevées. De plus, les comparaisons avec les résultats numériques obtenus en négligeant les effets capillaires sont effectuées. Des corrélations permettant de calculer les vitesses moyenne et fluctuante sont proposées. L'évolution temporelle de rayon de courbure au voisinage du nez de la poche est également étudiée pour les différentes accélérations et les résultats sont comparés avec le cas stagnant. Pour les accélérations élevées, la formation et la propagation des ondes oscillantes qui affectent la dynamique de l'écoulement sont quantifiéesThe present work deals with the motion of a Taylor bubble rising through vertical oscillating pipes. The aim is to perform a more detailed and experimental quantitative study of this unsteady flow, still seldom addressed in the literature. The investigation is restricted to high Reynolds numbers to understand inertia effects. Experimental results are provided for two different configurations : 1) pipes with two different inner diameters (9.8 mm and 20 mm) filled with water, 2) the thinner pipe (D=9.8 mm) filled with four low viscous fluids. So the Bond number Bo, based on the steady rise velocity varies from 13 to 57, where the effects of surface tension can be considered. The bubble trajectory is tracked by using a high-speed video camera. The average terminal and fluctuating velocity, as well as the phase shift with the oscillating plate are obtained by using image processing. The main results show that for weak acceleration, the mean velocity decreases with the relative acceleration as the fluctuating velocity increases in proportion to this acceleration. Beyond a critical relative acceleration, the average velocity increases and the fluctuating velocity increase seems to slow down. This behavior change seems to be related to the interface deformation (modified curvature, surface waves) which becomes significant in high accelerations. Additionally, comparisons are made with the numerical results obtained by neglecting the capillary effects. Correlations allowing the prediction of mean and fluctuating velocities depending on the Bond number and relative acceleration are proposed and compared with our experimental results. The time evolution of the radii of curvature in the vicinity of the bubble nose is also studied for different relative accelerations and the results are compared with the stagnant case. In high accelerations, the formation and propagation of surface waves which may influence the bubble dynamics are quantifie

    Contributions expérimentales sur la dynamique instationnaire de bulles de Taylor

    No full text
    Cette étude porte sur la dynamique instationnaire d'une bulle de Taylor dans un tube vertical en repère oscillant. L'objectif est de réaliser une étude expérimentale quantitative plus détaillée de cet écoulement instationnaire, très peu abordé dans la littérature. Les résultats expérimentaux sont obtenus pour des grands nombres de Reynolds pour comprendre les effets d'inertie. Deux configurations différentes sont étudiées : 1) tubes avec deux diamètres internes différents (9,8 mm et 20 mm) remplis d'eau, 2) le tube de diamètre D=9,8 mm rempli de quatre fluides peu visqueux. Le nombre de Bond Bo, basé sur la vitesse ascendante en cas stagnant, varie alors entre 13 et 57, où les effets de la tension superficielle peuvent être pris en compte. La bulle est suivie à l'aide d'une caméra rapide. les vitesses moyenne et fluctuante et le déphasage avec le plateau oscillant sont obtenus par traitement d'images et traitement numérique des données. Les résultats principaux montrent que pour les faibles accélérations la vitesse moyenne diminue et la vitesse fluctuante augmente lorsque l'accélération relative augmente. Au delà d'une accélération critique, la vitesse moyenne augmente et l'augmentation de la vitesse fluctuante semble ralentir. Ce changement de comportement semble être lié à la déformation de l'interface (courbure modifiée, ondes de surface) qui devient significative aux accélérations élevées. De plus, les comparaisons avec les résultats numériques obtenus en négligeant les effets capillaires sont effectuées. Des corrélations permettant de calculer les vitesses moyenne et fluctuante sont proposées. L'évolution temporelle de rayon de courbure au voisinage du nez de la poche est également étudiée pour les différentes accélérations et les résultats sont comparés avec le cas stagnant. Pour les accélérations élevées, la formation et la propagation des ondes oscillantes qui affectent la dynamique de l'écoulement sont quantifiéesThe present work deals with the motion of a Taylor bubble rising through vertical oscillating pipes. The aim is to perform a more detailed and experimental quantitative study of this unsteady flow, still seldom addressed in the literature. The investigation is restricted to high Reynolds numbers to understand inertia effects. Experimental results are provided for two different configurations : 1) pipes with two different inner diameters (9.8 mm and 20 mm) filled with water, 2) the thinner pipe (D=9.8 mm) filled with four low viscous fluids. So the Bond number Bo, based on the steady rise velocity varies from 13 to 57, where the effects of surface tension can be considered. The bubble trajectory is tracked by using a high-speed video camera. The average terminal and fluctuating velocity, as well as the phase shift with the oscillating plate are obtained by using image processing. The main results show that for weak acceleration, the mean velocity decreases with the relative acceleration as the fluctuating velocity increases in proportion to this acceleration. Beyond a critical relative acceleration, the average velocity increases and the fluctuating velocity increase seems to slow down. This behavior change seems to be related to the interface deformation (modified curvature, surface waves) which becomes significant in high accelerations. Additionally, comparisons are made with the numerical results obtained by neglecting the capillary effects. Correlations allowing the prediction of mean and fluctuating velocities depending on the Bond number and relative acceleration are proposed and compared with our experimental results. The time evolution of the radii of curvature in the vicinity of the bubble nose is also studied for different relative accelerations and the results are compared with the stagnant case. In high accelerations, the formation and propagation of surface waves which may influence the bubble dynamics are quantifiedNANCY-INPL-Bib. électronique (545479901) / SudocSudocFranceF

    Investigation of Effective Parameters on Size of Paclitaxel Loaded PLGA Nanoparticles

    No full text
    Purpose: The size of polymeric nanoparticles is considered as an effective factor in cancer therapy due to enterance into tumor tissue via the EPR effect. The purpose of this work was to investigate the effective parameters on poly(lactic-co-glycolic acid)-paclitaxel (PLGA –PTX) nanoparticles size. Methods: We prepared PLGA-PTX nanoparticles via single emulsion and precipitation methods with variable paremeters including drug concentration, aqueous to organic phase volume ratio, polymer concentration, sonication time and PVA concentration. Results: PLGA-PTX nanoparticles were characterized by dynamic light scattering (DLS) and scanning electron microscopy (SEM). The results exhibited that the diameter of nanoparticles enhanced with increasing drug, polymer and PVA concentrations whereas organic to aqueous phase volume ratio and sonication time required to the optimization for a given size. Conclusion: The precipitation method provides smaller nanoparticles compared to emulsion one. Variable parameters including drug concentration, aqueous to organic phase volume ratio, polymer concentration, sonication time and PVA concentration affect diameter of nanoparticles
    corecore