22 research outputs found

    A randomised controlled trial of blood pressure self-monitoring in the management of hypertensive pregnancy. OPTIMUM-BP:A feasibility trial

    Get PDF
    Objective: To assess the feasibility of a blood pressure self-monitoring intervention for managing pregnancy hypertension. Study design: OPTIMUM-BP was an unmasked randomised controlled trial comparing a self-monitoring of blood pressure (SMBP) intervention versus usual care for the management of pregnancy hypertension. Women with chronic (CH) or gestational hypertension (GH) from 4 UK centres were randomised (2:1) intervention to control. Self-monitoring involved daily home blood pressure (BP) measurements, with recording via study diary or telemonitoring. Clinicians were invited to use the home readings in clinical and antihypertensive titration decisions. Main outcomes: The primary outcomes were recruitment, retention, adherence and persistence with the intervention. Results: Women from four UK centres were randomised: 158/222 (71%) of those approached agreed, comprising: 86 women with chronic hypertension (55 SMBP, 31 control) and 72 with gestational hypertension (49 SMBP, 23 control) of whom outcome data were available from 154 (97%) and were included in the analysis. The median (IQR) number of days with home BP readings per week were 5.5 (3.1–6.5) for those with chronic hypertension and 6.1 (4.5–6.7) with gestational hypertension. Participants persisted with the intervention for 80% or more of their time from enrolment until delivery in 86% (43/50) and 76% (38/49) of those with chronic and gestational hypertension respectively. Recorded clinic and study BPs were similar for both groups. Conclusions: This is the first randomised investigation of BP self-monitoring for the management of pregnancy hypertension and indicates that a large RCT would be feasible.</p

    Blood pressure self-monitoring in pregnancy (BuMP) feasibility study; a qualitative analysis of women's experiences of self-monitoring

    Get PDF
    Background Hypertensive disorders in pregnancy are a leading cause of maternal and fetal morbidity worldwide. Raised blood pressure (BP) affects 10% of pregnancies worldwide, of which almost half develop pre-eclampsia. The proportion of pregnant women who have risk factors for pre-eclampsia (such as pre-existing hypertension, obesity and advanced maternal age) is increasing. Pre-eclampsia can manifest itself before women experience symptoms and can develop between antenatal visits. Incentives to improve early detection of gestational hypertensive disorders are therefore strong and self-monitoring of blood pressure (SMBP) in pregnancy might be one means to achieve this, whilst improving women’s involvement in antenatal care. The Blood Pressure Self-Monitoring in Pregnancy (BuMP) study aimed to evaluate the feasibility and acceptability of SMBP in pregnancy. Methods To understand women’s experiences of SMBP during pregnancy, we undertook a qualitative study embedded within the BuMP observational feasibility study. Women who were at higher risk of developing hypertension and/or pre-eclampsia were invited to take part in a study using SMBP and also invited to take part in an interview. Semi-structured interviews were conducted at the women’s homes in Oxfordshire and Birmingham with women who were self-monitoring their BP as part of the BuMP feasibility study in 2014. Interviews were conducted by a qualitative researcher and transcribed verbatim. A framework approach was used for analysis. Results Fifteen women agreed to be interviewed. Respondents reported general willingness to engage with monitoring their own BP, feeling that it could reduce anxiety around their health during pregnancy, particularly if they had previous experience of raised BP or pre-eclampsia. They felt able to incorporate self-monitoring into their weekly routines, although this was harder post-partum. Self-monitoring of BP made them more aware of the risks of hypertension and pre-eclampsia in pregnancy. Feelings of reassurance and empowerment were commonly reported by the women in our sample

    Blood pressure self-monitoring in pregnancy: examining feasibility in a prospective cohort study

    Get PDF
    Background: Raised blood pressure (BP) affects approximately 10% of pregnancies worldwide, and a high proportion of affected women develop pre-eclampsia. This study aimed to evaluate the feasibility of self-monitoring of BP in pregnancy in women at higher risk of pre-eclampsia. Methods: This prospective cohort study of self-monitoring BP in pregnancy was carried out in two hospital trusts in Birmingham and Oxford and thirteen primary care practices in Oxfordshire. Eligible women were those defined by the UK National Institute for Health and Care Excellence (NICE) guidelines as at higher risk of pre-eclampsia. A total of 201 participants were recruited between 12 and 16 weeks of pregnancy and were asked to take two BP readings twice daily three times a week through their pregnancy. Primary outcomes were recruitment, retention and persistence of self-monitoring. Study recruitment and retention were analysed with descriptive statistics. Survival analysis was used to evaluate the persistence of self-monitoring and the performance of self-monitoring in the early detection of gestational hypertension, compared to clinic BP monitoring. Secondary outcomes were the mean clinic and self-monitored BP readings and the performance of self-monitoring in the detection of gestational hypertension and pre-eclampsia compared to clinic BP. Results: Of 201 women recruited, 161 (80%) remained in the study at 36 weeks or to the end of their pregnancy, 162 (81%) provided any home readings suitable for analysis, 148 (74%) continued to self-monitor at 20 weeks and 107 (66%) at 36 weeks. Self-monitored readings were similar in value to contemporaneous matched clinic readings for both systolic and diastolic BP. Of the 23 who developed gestational hypertension or pre-eclampsia and self-monitored, 9(39%) had a raised home BP prior to a raised clinic BP. Conclusions: Self-monitoring of BP in pregnancy is feasible and has potential to be useful in the early detection of gestational hypertensive disorders but maintaining self-monitoring throughout pregnancy requires support and probably enhanced training

    International gestational age-specific centiles for blood pressure in pregnancy from the INTERGROWTH-21st Project in 8 countries: A longitudinal cohort study.

    Get PDF
    BACKGROUND: Gestational hypertensive and acute hypotensive disorders are associated with maternal morbidity and mortality worldwide. However, physiological blood pressure changes in pregnancy are insufficiently defined. We describe blood pressure changes across healthy pregnancies from the International Fetal and Newborn Growth Consortium for the 21st Century (INTERGROWTH-21st) Fetal Growth Longitudinal Study (FGLS) to produce international, gestational age-specific, smoothed centiles (third, 10th, 50th, 90th, and 97th) for blood pressure. METHODS AND FINDINGS: Secondary analysis of a prospective, longitudinal, observational cohort study (2009 to 2016) was conducted across 8 diverse urban areas in Brazil, China, India, Italy, Kenya, Oman, the United Kingdom, and the United States of America. We enrolled healthy women at low risk of pregnancy complications. We measured blood pressure using standardised methodology and validated equipment at enrolment at 14 mmHg or diastolic blood pressure by >11 mmHg in fewer than 10% of women at any gestational age. Fewer than 10% of women increased their systolic blood pressure by >24 mmHg or diastolic blood pressure by >18 mmHg at any gestational age. The study's main limitations were the unavailability of prepregnancy blood pressure values and inability to explore circadian effects because time of day was not recorded for the blood pressure measurements. CONCLUSIONS: Our findings provide international, gestational age-specific centiles and limits of acceptable change to facilitate earlier recognition of deteriorating health in pregnant women. These centiles challenge the idea of a clinically significant midpregnancy drop in blood pressure

    Systemic lupus erythematosus

    No full text
    Systemic lupus erythematosus in pregnancy brings risks for the mother, and possible harm to the fetus if the disease is treated. This article discusses the challenges of managemen

    Placental Growth Factor (PlGF) in Women with Suspected Pre-Eclampsia Prior to 35 Weeks' Gestation: A Budget Impact Analysis.

    Get PDF
    ObjectiveTo model the resource implications of placental growth factor (PlGF) testing in women with suspected pre-eclampsia prior to 35 weeks' gestation as part of a management algorithm, compared with current practice.MethodsData on resource use from 132 women with suspected pre-eclampsia prior to 35 weeks' gestation, enrolled in a prospective observational cohort study evaluating PlGF measurement within antenatal assessment units within two UK consultant-led maternity units was extracted by case note review. A decision analytic model was developed using these data to establish the budget impact of managing women with suspected pre-eclampsia for two weeks from the date of PlGF testing, using a clinical management algorithm and reference cost tariffs. The main outcome measures of resource use (numbers of outpatient appointments, ultrasound investigations and hospital admissions) were correlated to final diagnosis and used to calculate comparative management regimes.ResultsThe mean cost saving associated with the PlGF test (in the PlGF plus management arm) was £35,087 (95% CI -£33,181 to -£36,992) per 1,000 women. This equated to a saving of £582 (95% CI -552 to -£613) per woman tested. In 94% of iterations, PlGF testing was associated with cost saving compared to current practice.ConclusionsThis analysis suggests PlGF used as part of a clinical management algorithm in women presenting with suspected pre-eclampsia prior to 35 weeks' gestation could provide cost savings by reducing unnecessary resource use. Introduction of PlGF testing could be used to direct appropriate resource allocation and overall would be cost saving

    Two-week costs of PlGF cost plus treatment algorithm compared to current practice for 1,000 pregnant women based on correct identification of women without a final diagnosis of pre-eclampsia (deterministic).

    No full text
    <p>Two-week costs of PlGF cost plus treatment algorithm compared to current practice for 1,000 pregnant women based on correct identification of women without a final diagnosis of pre-eclampsia (deterministic).</p

    Flow diagram of algorithm using PlGF concentrations.

    No full text
    <p>Numbers shown in boxes relate to the numbers of women (from population of 1000 pregnant women) in the adjacent box.</p
    corecore