27,375 research outputs found

    Sun-synchronous highly elliptical orbits using low-thrust propulsion

    Get PDF
    Due to restrictions within the current architecture of the global observing system (GOS), space-based remote sensing of Earth suffers from an acute data-deficit over the critical polar-regions. Currently, observation of high-latitude regions is conducted using composite images from spacecraft in geostationary (GEO) and low-Earth orbits (LEOs) [1]. However, the oblique viewing geometry from GEO-based systems to latitudes above around 55 deg [2] and the insufficient temporal resolution of spacecraft in LEO means there is currently no source of continuous imagery for polar-regions obtained with a data refresh rate of less than 15 minutes, as is typically available elsewhere for meteorological observations

    Neonatal weight loss in breast and formula-fed infants

    Get PDF
    We have observed an increase in the number of breast fed babies presenting with dehydration and/or failure to thrive because of lactation failure and non-recognition of feeding problems. Recent reports1,2 support this experience and recommend monitoring of the weight of infants through the neonatal period. However, these reports acknowledge uncertainty as to what actually constitutes normal neonatal weight loss. Maisels and colleagues published two studies which have been quoted as giving guidance on normal loss. Both studies were designed primarily to study factors that influence breast milk jaundice. The first3 reported a mean weight loss of about 6% in 100 unselected well babies during the first 3 days. The subsequent study4 reported a mean weight loss of 6.86% in 186 infants. The timescale over which babies were weighed was not clearly indicated, although it may have only been 2-3 days. The sample was neither population based nor randomly selected, being largely preselected because of the presence of more pronounced jaundice. The distribution of data points for early neonatal weight loss are likely to be skewed, yet both studies reported the results as mean (SD). Owing to the design and method of data presentation, these studies cannot reliably inform the debate as to what constitutes the norm. Marchini and colleagues published reports also designed primarily to study other issues. One5 indicated a mean early weight loss of 5.7%. Measurements were recorded over a three day period, and no indication is given of the skewness of the data. Another study6 reported a median weight loss of about 6% recorded over a four day period. At least one baby lost > 15% of his/her birth weight during this time, but there is no clear information as to the frequency with which more extreme degrees of weight loss are observed

    Spin wave dispersion in La2CuO4

    Full text link
    We calculate the antiferromagnetic spin wave dispersion in the half-filled Hubbard model for a two-dimensional square lattice and find it to be in excellent agreement with recent high-resolution inelastic neutron scattering performed on La2CuO4 [Phys. Rev. Lett. 86, 5377 (2001)].Comment: typos correcte

    Magnetic interactions of substitutional Mn pairs in GaAs

    Full text link
    We employ a kinetic-exchange tight-binding model to calculate the magnetic interaction and anisotropy energies of a pair of substitutional Mn atoms in GaAs as a function of their separation distance and direction. We find that the most energetically stable configuration is usually one in which the spins are ferromagnetically aligned along the vector connecting the Mn atoms. The ferromagnetic configuration is characterized by a splitting of the topmost unoccupied acceptor levels, which is visible in scanning tunneling microscope studies when the pair is close to the surface and is strongly dependent on pair orientation. The largest acceptor splittings occur when the Mn pair is oriented along the symmetry direction, and the smallest when they are oriented along . We show explicitly that the acceptor splitting is not simply related to the effective exchange interaction between the Mn local moments. The exchange interaction constant is instead more directly related to the width of the distribution of all impurity levels -- occupied and unoccupied. When the Mn pair is at the (110) GaAs surface, both acceptor splitting and effective exchange interaction are very small except for the smallest possible Mn separation.Comment: 25 figure

    Magnetic properties of substitutional Mn in (110) GaAs surface and subsurface layers

    Full text link
    Motivated by recent STM experiments, we present a theoretical study of the electronic and magnetic properties of the Mn-induced acceptor level obtained by substituting a single Ga atom in the (110) surface layer of GaAs or in one of the atoms layers below the surface. We employ a kinetic-exchange tight-binding model in which the relaxation of the (110) surface is taken into account. The acceptor wave function is strongly anisotropic in space and its detailed features depend on the depth of the sublayer in which the Mn atom is located. The local-density-of-states (LDOS) on the (110) surface associated with the acceptor level is more sensitive to the direction of the Mn magnetic moment when the Mn atom is located further below the surface. We show that the total magnetic anisotropy energy of the system is due almost entirely to the dependence of the acceptor level energy on Mn spin orientation, and that this quantity is strongly dependent on the depth of the Mn atom.Comment: 14 pages, 13 figure

    Experimental and numerical study of local mean age of air

    Get PDF
    This paper presents the results from the experimental and numerical study of a room with mixing ventilation, focused on the local mean age of air (LMA). The measurements were performed using the tracer gas concentration decay method. The numerical predictions were obtained from the computational fluid dynamics (CFD) module of the latest version of the ESP-r software

    Fully Frustrated Cold Atoms

    Full text link
    Fully frustrated Josephson Junction arrays (FF-JJA's) exhibit a subtle compound phase transition in which an Ising transition associated with discrete broken translational symmetry and a Berezinskii-Kosterlitz-Thouless (BKT) transition associated with quasi-long-range phase coherence occur nearly simultaneously. In this Letter we discuss a cold atom realization of the FF-JJA system. We demonstrate that both orders can be studied by standard momentum-distribution-function measurements and present numerical results, based on a successful self-consistent spin-wave approximation, that illustrate the expected behavior of observables.Comment: 5 pages, 3 figures, submitte

    Ion observations from geosynchronous orbit as a proxy for ion cyclotron wave growth during storm times

    Get PDF
    [1] There is still much to be understood about the processes contributing to relativistic electron enhancements and losses in the radiation belts. Wave particle interactions with both whistler and electromagnetic ion cyclotron (EMIC) waves may precipitate or accelerate these electrons. This study examines the relation between EMIC waves and resulting relativistic electron flux levels after geomagnetic storms. A proxy for enhanced EMIC waves is developed using Los Alamos National Laboratory Magnetospheric Plasma Analyzer plasma data from geosynchronous orbit in conjunction with linear theory. In a statistical study using superposed epoch analysis, it is found that for storms resulting in net relativistic electron losses, there is a greater occurrence of enhanced EMIC waves. This is consistent with the hypothesis that EMIC waves are a primary mechanism for the scattering of relativistic electrons and thus cause losses of such particles from the magnetosphere

    Nanoscale Torsional Optomechanics

    Full text link
    Optomechanical transduction is demonstrated for nanoscale torsional resonators evanescently coupled to optical microdisk whispering gallery mode resonators. The on-chip, integrated devices are measured using a fully fiber-based system, including a tapered and dimpled optical fiber probe. With a thermomechanically calibrated optomechanical noise floor down to 7 fm/sqrt(Hz), these devices open the door for a wide range of physical measurements involving extremely small torques, as little as 4x10^-20 N*m.Comment: 4 pages, 4 figures - Accepted to APL Oct 22nd, 2012. To appear in February 4th issue - as cover articl
    • 

    corecore