200 research outputs found

    Yield Performances and Cup Quality of Some BTRI Test Clones of Tea

    Get PDF
    A long term experiment was conducted to investigate the yield and quality performances of four vegetative propagated test clones of tea coded as A/8/01, A/17/22, A/22/27 and A/22/40 at Bangladesh Tea Research Institute (BTRI) farm during 1996-2010. A standard clone BT1 was considered as control. Cuttings of the test clones were collected from the selected bushes of Amo tea estates and were raised at BTRI nursery. Then saplings were put to long term yield and quality trial following Latin Square Design (LSD) with 3 replications. The green leaf was harvested at weekly interval during the plucking season starting from mid March to mid December throughout the experimental period. Yield data were recorded and analyzed statistically using MSTAT programme. Results of the experiment revealed that among the test clones A/22/40 gave the highest significant yield of 3509.1 kg ha-1 of made tea followed by BT1 (3203.69 kg ha-1), A/8/01 (2912.24 kg ha-1), A/17/22 (2817.76 kg ha-1) and A/22/27 (2278.78 kg ha-1) from the average of 9 years (2002-2010) at mature stage. At immature stage i.e. 1st year to 5th year after plantation yield difference was insignificant. The overall cup quality of the test clones was assessed by conventional organoleptic test. The cup quality of A/8/01, A/17/22, A/22/40 as well as the standard clone BT1 was found to be above average (AA) while the cup quality of A/22/27 was average (A). Considering the yield and quality potentials, the test clone A/22/40 has appeared quite promising to be released as a standard clone. DOI: http://dx.doi.org/10.3329/ijarit.v1i1-2.13925 Int. J. Agril. Res. Innov. & Tech. 1 (1&2): 24-28, December, 201

    Review of coal fired power plants in Bangladesh

    Get PDF
    This article is based on the current and future coal power plants of Bangladesh. Although, it is known to all that, coal fired power plants are the great sources of carbon and other pollutant ingredients. But it has several positive impacts for developing countries like Bangladesh, where there is a lack of natural resources, lands and unstable economy. Bangladesh government has a vision to supply the electricity all over the country of Bangladesh, from Teknaf to Tetulia, and also for the remote islands also. In this paper, energy demand and vision of Bangladesh government is discussed in section 1. Section 2, gives the answer, why coal fired power plant is necessary for Bangladesh. In section 3, impacts of coal fired power plant is discussed and showed all current power plants in a table. Section 4 comprises with the future of coal fired power plant in Bangladesh

    Study on physicochemical status, bacterial analysis and its correlation

    Get PDF
    Swimming pool, as a recreational facility is now a part of current lifestyle that offers social and health benefits. More demand for hotels with swimming pool facility and are highly used during peak seasons. However swimming pool could become a pooling medium of various bacteria came from the bathers, air and soils thus risk of water-borne disease and impose hazard to human health. Therefore, a well disinfected swimming pool that meets the minimum standard requirement must be reached. This study aimed to assess the status of physicochemical parameters including free chlorine, pH, and temperature and to assess status of bacteria analysis of swimming pool water samples. 11 swimming pool water samples were taken from hotels in Klang valley, Malaysia. The physicochemical parameters were tested using colorimetric method using N,N-diethyl-1,4-phenylenediamine and bacteria analysis were obtained by standard plate count (SPC) method. Results are presented in mean and standard deviation. Correlation coefficient is obtained by Pearson’s correlation statistical test. Results showed mean of temperature 29.64±1.430C, pH 7.56±0.40, free chlorine 1.22±1.16 ppm and bacterial SPC 4,825.64±8,409.16cfu/ml. Correlation-coefficient between temperature and SPC r: 0.71. The findings showed current physicochemical status of hotel swimming pool water samples met the minimum standard requirement. However, the bacterial SPC is highly above acceptable range and positively correlated to temperature. This indicates bacterial count increase with temperature rise despite of acceptable chlorine level. The acceptable level of chlorine as disinfectant is insufficient to oxidize bacteria thus may put the swimming pool water at risk of spreading water borne diseases. This finding suggests increase dosage of chlorine is required to maintain swimming pool sanitation during hot season in order to provide a safe water recreational facility. However, larger sample size is required to confirm the findings website
    • …
    corecore