450 research outputs found

    Ultrasensitive force and displacement detection using trapped ions

    Full text link
    The ability to detect extremely small forces is vital for a variety of disciplines including precision spin-resonance imaging, microscopy, and tests of fundamental physical phenomena. Current force-detection sensitivity limits have surpassed 1 aN/HzaN/\sqrt{Hz} (atto =1018=10^{-18}) through coupling of micro or nanofabricated mechanical resonators to a variety of physical systems including single-electron transistors, superconducting microwave cavities, and individual spins. These experiments have allowed for probing studies of a variety of phenomena, but sensitivity requirements are ever-increasing as new regimes of physical interactions are considered. Here we show that trapped atomic ions are exquisitely sensitive force detectors, with a measured sensitivity more than three orders of magnitude better than existing reports. We demonstrate detection of forces as small as 174 yNyN (yocto =1024=10^{-24}), with a sensitivity 390±150\pm150 yN/HzyN/\sqrt{Hz} using crystals of n=60n=60 9^{9}Be+^{+} ions in a Penning trap. Our technique is based on the excitation of normal motional modes in an ion trap by externally applied electric fields, detection via and phase-coherent Doppler velocimetry, which allows for the discrimination of ion motion with amplitudes on the scale of nanometers. These experimental results and extracted force-detection sensitivities in the single-ion limit validate proposals suggesting that trapped atomic ions are capable of detecting of forces with sensitivity approaching 1 yN/HzyN/\sqrt{Hz}. We anticipate that this demonstration will be strongly motivational for the development of a new class of deployable trapped-ion-based sensors, and will permit scientists to access new regimes in materials science.Comment: Expanded introduction and analysis. Methods section added. Subject to press embarg

    Variability and Predictors of Urinary Bisphenol A Concentrations during Pregnancy

    Get PDF
    BackgroundPrenatal bisphenol A (BPA) exposure may be associated with developmental toxicity, but few studies have examined the variability and predictors of urinary BPA concentrations during pregnancy.ObjectiveOur goal was to estimate the variability and predictors of serial urinary BPA concentrations taken during pregnancy.MethodsWe measured BPA concentrations during pregnancy and at birth in three spot urine samples from 389 women. We calculated the intraclass correlation coefficient (ICC) to assess BPA variability and estimated associations between log10-transformed urinary BPA concentrations and demographic, occupational, dietary, and environmental factors, using mixed models.ResultsGeometric mean (GM) creatinine-standardized concentrations (micrograms per gram) were 1.7 (16 weeks), 2.0 (26 weeks), and 2.0 (birth). Creatinine-standardized BPA concentrations exhibited low reproducibility (ICC = 0.11). By occupation, cashiers had the highest BPA concentrations (GM: 2.8 μg/g). Consuming canned vegetables at least once a day was associated with higher BPA concentrations (GM = 2.3 μg/g) compared with those consuming no canned vegetables (GM = 1.6 μg/g). BPA concentrations did not vary by consumption of fresh fruits and vegetables, canned fruit, or store-bought fresh and frozen fish. Urinary high-molecular-weight phthalate and serum tobacco smoke metabolite concentrations were positively associated with BPA concentrations.ConclusionsThese results suggest numerous sources of BPA exposure during pregnancy. Etiological studies may need to measure urinary BPA concentrations more than once during pregnancy and adjust for phthalates and tobacco smoke exposures

    A genotype-guided strategy for oral P2Y₁₂ Inhibitors in primary PCI

    Get PDF
    BACKGROUND: It is unknown whether patients undergoing primary percutaneous coronary intervention (PCI) benefit from genotype-guided selection of oral P2Y12 inhibitors. METHODS: We conducted a randomized, open-label, assessor-blinded trial in which patients undergoing primary PCI with stent implantation were assigned in a 1:1 ratio to receive either a P2Y12 inhibitor on the basis of early CYP2C19 genetic testing (genotype-guided group) or standard treatment with either ticagrelor or prasugrel (standard-treatment group) for 12 months. In the genotype-guided group, carriers of CYP2C19*2 or CYP2C19*3 loss-of-function alleles received ticagrelor or prasugrel, and noncarriers received clopidogrel. The two primary outcomes were net adverse clinical events - defined as death from any cause, myocardial infarction, definite stent thrombosis, stroke, or major bleeding defined according to Platelet Inhibition and Patient Outcomes (PLATO) criteria - at 12 months (primary combined outcome; tested for noninferiority, with a noninferiority margin of 2 percentage points for the absolute difference) and PLATO major or minor bleeding at 12 months (primary bleeding outcome). RESULTS: For the primary analysis, 2488 patients were included: 1242 in the genotype-guided group and 1246 in the standard-treatment group. The primary combined outcome occurred in 63 patients (5.1%) in the genotype-guided group and in 73 patients (5.9%) in the standard-treatment group (absolute difference, -0.7 percentage points; 95% confidence interval [CI], -2.0 to 0.7; P<0.001 for noninferiority). The primary bleeding outcome occurred in 122 patients (9.8%) in the genotype-guided group and in 156 patients (12.5%) in the standard-treatment group (hazard ratio, 0.78; 95% CI, 0.61 to 0.98; P = 0.04). CONCLUSIONS: In patients undergoing primary PCI, a CYP2C19 genotype-guided strategy for selection of oral P2Y12 inhibitor therapy was noninferior to standard treatment with ticagrelor or prasugrel at 12 months with respect to thrombotic events and resulted in a lower incidence of bleeding. (Funded by the Netherlands Organization for Health Research and Development; POPular Genetics ClinicalTrials.gov number, NCT01761786; Netherlands Trial Register number, NL2872.)

    Bayesian calibration, validation and uncertainty quantification for predictive modelling of tumour growth: a tutorial

    Get PDF
    In this work we present a pedagogical tumour growth example, in which we apply calibration and validation techniques to an uncertain, Gompertzian model of tumour spheroid growth. The key contribution of this article is the discussion and application of these methods (that are not commonly employed in the field of cancer modelling) in the context of a simple model, whose deterministic analogue is widely known within the community. In the course of the example we calibrate the model against experimental data that is subject to measurement errors, and then validate the resulting uncertain model predictions. We then analyse the sensitivity of the model predictions to the underlying measurement model. Finally, we propose an elementary learning approach for tuning a threshold parameter in the validation procedure in order to maximize predictive accuracy of our validated model

    Efficacy of imidacloprid + moxidectin and selamectin topical solutions against the KS1 Ctenocephalides felis flea strain infesting cats

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Two studies were conducted to evaluate and compare the efficacy of imidacloprid + moxidectin and selamectin topical solutions against the KS1 flea strain infesting cats. In both studies the treatment groups were comprised of non-treated controls, 6% w/v selamectin (Revolution<sup>®</sup>; Pfizer Animal Health) topical solution and 10% w/v imidacloprid + 1% w/v moxidectin (Advantage <it>Multi</it><sup>® </sup>for Cats, Bayer Animal Health) topical solution. All cats were infested with 100 fleas on Days -2, 7, 14, 21, and 28. The difference in the studies was that in study #1 efficacy evaluations were conducted at 24 and 48 hours post-treatment or post-infestation, and in study #2 evaluations were conducted at 12 and 24 hours.</p> <p>Results</p> <p>In study #1 imidacloprid + moxidectin and the selamectin formulation provided 99.8% and 99.0% efficacy at 24 hours post-treatment. On day 28, the 24 hour efficacy of the selamectin formulation dropped to 87.1%, whereas the imidacloprid + moxidectin formulation provided 98.9% efficacy. At the 48 hour assessments following the 28 day infestations, efficacy of the imidacloprid + moxidectin and selamectin formulations was 96.8% and 98.3% respectively. In study # 2 the efficacy of the imidacloprid + moxidectin and selamectin formulations 12 hours after treatment was 100% and 69.4%, respectively. On day 28, efficacy of the imidacloprid + moxidectin and selamectin formulations 12 hours after infestation was 90.2% and 57.3%, respectively. In study #2 both formulations provided high levels of efficacy at the 24 hour post-infestation assessments, with selamectin and imidacloprid + moxidectin providing 95.3% and 97.5% efficacy, following infestations on day 28.</p> <p>Conclusions</p> <p>At the 24 and 48 hour residual efficacy assessments, the imidacloprid + moxidectin and selamectin formulations were similarly highly efficacious. However, the imidacloprid + moxidectin formulation provided a significantly higher rate of flea kill against the KS1 flea strain infesting cats at every 12 hour post-infestation residual efficacy assessment. Both formulations should provide excellent flea control for an entire month on cats.</p
    corecore