57 research outputs found

    Neurophysiological modeling of bladder afferent activity in the rat overactive bladder model

    Get PDF
    The overactive bladder (OAB) is a syndrome-based urinary dysfunction characterized by “urgency, with or without urge incontinence, usually with frequency and nocturia”. Earlier we developed a mathematical model of bladder nerve activity during voiding in anesthetized rats and found that the nerve activity in the relaxation phase of voiding contractions was all afferent. In the present study, we applied this mathematical model to an acetic acid (AA) rat model of bladder overactivity to study the sensitivity of afferent fibers in intact nerves to bladder pressure and volume changes. The afferent activity in the filling phase and the slope, i.e., the sensitivity of the afferent fibers to pressure changes in the post-void relaxation phase, were found to be significantly higher in AA than in saline measurements, while the offset (nerve activity at pressure ~0) and maximum pressure were comparable. We have thus shown, for the first time, that the sensitivity of afferent fibers in the OAB can be studied without cutting nerves or preparation of single fibers. We conclude that bladder overactivity induced by AA in rats is neurogenic in origin and is caused by increased sensitivity of afferent sensors in the bladder wall

    Saphenofemoral arteriovenous fistula as hemodialysis access

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>An upper limb arteriovenous (AV) fistula is the access of choice for haemodialysis (HD). There have been few reports of saphenofemoral AV fistulas (SFAVF) over the last 10-20 years because of previous suggestions of poor patencies and needling difficulties. Here, we describe our clinical experience with SFAVF.</p> <p>Methods</p> <p>SFAVFs were evaluated using the following variables: immediate results, early and late complications, intraoperative and postoperative complications (up to day 30), efficiency of the fistula after the onset of needling and complications associated to its use.</p> <p>Results</p> <p>Fifty-six SFAVF fistulas were created in 48 patients. Eight patients had two fistulas: 8 patent (16%), 10 transplanted (20%), 12 deaths (24%), 1 low flow (2%) and 20 thrombosis (39%) (first two months of preparation). One patient had severe hypotension during surgery, which caused thrombosis of the fistula, which was successfully thrombectomised, four thrombosed fistulae were successfully thrombectomised and revised on the first postoperative day. After 59 months of follow-up, primary patency was 44%.</p> <p>Conclusion</p> <p>SFAVF is an adequate alternative for patients without the possibility for other access in the upper limbs, allowing efficient dialysis with good long-term patency with a low complication rate.</p

    Single Center Review of Femoral Arteriovenous Grafts for Hemodialysis

    Full text link
    It is unclear how to manage high risk hemodialysis patients who present with an indwelling catheter. The National Kidney Foundation Practice Guidelines urge prompt removal of the catheter, but the guidelines do not specifically address the problem of patients whose only option is a femoral arteriovenous (AV) graft.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/41306/1/268_2005_Article_62.pd

    Blood in Urine

    No full text
    • …
    corecore