3,944 research outputs found

    Being Men & Women Together

    Get PDF

    What Do You Want To Make Those Eyes At Me For?

    Get PDF
    https://digitalcommons.library.umaine.edu/mmb-vp/2650/thumbnail.jp

    Exploring the length scales, timescales and chemistry of challenging materials (Part 2).

    Get PDF
    This themed issue explores the different length and timescales that determine the physics and chemistry of a variety of key of materials, explored from the perspective of a wide range of disciplines, including physics, chemistry materials science, Earth science and biochemistry. The topics discussed include catalysis, chemistry under extreme conditions, energy materials, amorphous and liquid structure, hybrid organic materials and biological materials. The issue is in two parts, with this second set of contributions exploring hybrid organic materials, catalysis low-dimensional and graphitic materials, biological materials and naturally occurring, super-hard material as well as dynamic high pressure and new developments in imaging techniques pressure. This article is part of the theme issue 'Exploring the length scales, timescales and chemistry of challenging materials (Part 2)'

    Exploring the length scales, timescales and chemistry of challenging materials (Part 1).

    Get PDF
    This themed issue explores the different length scales and timescales that determine the physics and chemistry of a variety of key materials, explored from the perspective of a wide range of disciplines, including physics, chemistry, materials science, Earth science and biochemistry. The topics discussed include catalysis, chemistry under extreme conditions, energy materials, amorphous and liquid structure, hybrid organic materials and biological materials. The issue is in two parts, with the present part exploring glassy and amorphous systems and materials at high pressure. This article is part of the theme issue 'Exploring the length scales, timescales and chemistry of challenging materials (Part 1)'

    Extending the applicability of the dose addition model to the assessment of chemical mixtures of partial agonists by using a novel toxic unit extrapolation method

    Get PDF
    This article has been made available through the Brunel Open Access Publishing Fund.Dose addition, a commonly used concept in toxicology for the prediction of chemical mixture effects, cannot readily be applied to mixtures of partial agonists with differing maximal effects. Due to its mathematical features, effect levels that exceed the maximal effect of the least efficacious compound present in the mixture, cannot be calculated. This poses problems when dealing with mixtures likely to be encountered in realistic assessment situations where chemicals often show differing maximal effects. To overcome this limitation, we developed a pragmatic solution that extrapolates the toxic units of partial agonists to effect levels beyond their maximal efficacy. We extrapolated different additivity expectations that reflect theoretically possible extremes and validated this approach with a mixture of 21 estrogenic chemicals in the E-Screen. This assay measures the proliferation of human epithelial breast cancers. We found that the dose-response curves of the estrogenic agents exhibited widely varying shapes, slopes and maximal effects, which made it necessary to extrapolate mixture responses above 14% proliferation. Our toxic unit extrapolation approach predicted all mixture responses accurately. It extends the applicability of dose addition to combinations of agents with differing saturating effects and removes an important bottleneck that has severely hampered the use of dose addition in the past. © 2014 Scholze et al

    Stiff person syndrome presenting with sudden onset of shortness of breath and difficulty moving the right arm: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>First described in 1956, stiff person syndrome is characterized by episodes of slowly progressive stiffness and rigidity in both the paraspinal and limb muscles. Although considered a rare disorder, stiff person syndrome is likely to be under-diagnosed due to a general lack of awareness of the disease in the medical community.</p> <p>Case presentation</p> <p>A 27-year-old Hispanic woman presented to our emergency department with a sudden onset of shortness of breath and difficulty moving her right arm. Her physical examination was remarkable in that her abdomen was firm to palpation and her right upper extremity was rigid on passive and active ranges of motion. Her right fingers were clenched in a fist. Her electromyography findings were consistent with stiff person syndrome in the right clinical setting. Stiff person syndrome is confirmed by testing for the anti-glutamic acid decarboxylase antibody. Her test for this was positive.</p> <p>Conclusion</p> <p>Stiff person syndrome may not be a common condition. However, if disregarded in the differential diagnosis, it can lead to several unnecessary tests being carried out causing a delay in treatment. This case report reveals some of the characteristic features of stiff person syndrome with an atypical presentation.</p

    Movement variability in stroke patients and controls performing two upper limb functional tasks: a new assessment methodology

    Get PDF
    Background: In the evaluation of upper limb impairment post stroke there remains a gap between detailed kinematic analyses with expensive motion capturing systems and common clinical assessment tests. In particular, although many clinical tests evaluate the performance of functional tasks, metrics to characterise upper limb kinematics are generally not applicable to such tasks and very limited in scope. This paper reports on a novel, user-friendly methodology that allows for the assessment of both signal magnitude and timing variability in upper limb movement trajectories during functional task performance. In order to demonstrate the technique, we report on a study in which the variability in timing and signal magnitude of data collected during the performance of two functional tasks is compared between a group of subjects with stroke and a group of individually matched control subjects. Methods: We employ dynamic time warping for curve registration to quantify two aspects of movement variability: 1) variability of the timing of the accelerometer signals' characteristics and 2) variability of the signals' magnitude. Six stroke patients and six matched controls performed several trials of a unilateral ('drinking') and a bilateral ('moving a plate') functional task on two different days, approximately 1 month apart. Group differences for the two variability metrics were investigated on both days. Results: For 'drinking from a glass' significant group differences were obtained on both days for the timing variability of the acceleration signals' characteristics (p = 0.002 and p = 0.008 for test and retest, respectively); all stroke patients showed increased signal timing variability as compared to their corresponding control subject. 'Moving a plate' provided less distinct group differences. Conclusion: This initial application establishes that movement variability metrics, as determined by our methodology, appear different in stroke patients as compared to matched controls during unilateral task performance ('drinking'). Use of a user-friendly, inexpensive accelerometer makes this methodology feasible for routine clinical evaluations. We are encouraged to perform larger studies to further investigate the metrics' usefulness when quantifying levels of impairment

    Simulation of the Response of the Inner Hair Cell Stereocilia Bundle to an Acoustical Stimulus

    Get PDF
    Mammalian hearing relies on a cochlear hydrodynamic sensor embodied in the inner hair cell stereocilia bundle. It is presumed that acoustical stimuli induce a fluid shear-driven motion between the tectorial membrane and the reticular lamina to deflect the bundle. It is hypothesized that ion channels are opened by molecular gates that sense tension in tip-links, which connect adjacent stepped rows of stereocilia. Yet almost nothing is known about how the fluid and bundle interact. Here we show using our microfluidics model how each row of stereocilia and their associated tip links and gates move in response to an acoustical input that induces an orbital motion of the reticular lamina. The model confirms the crucial role of the positioning of the tectorial membrane in hearing, and explains how this membrane amplifies and synchronizes the timing of peak tension in the tip links. Both stereocilia rotation and length change are needed for synchronization of peak tip link tension. Stereocilia length change occurs in response to accelerations perpendicular to the oscillatory fluid shear flow. Simulations indicate that nanovortices form between rows to facilitate diffusion of ions into channels, showing how nature has devised a way to solve the diffusive mixing problem that persists in engineered microfluidic devices
    • …
    corecore