51 research outputs found

    Leadless pacemaker technology: clinical evidence of new paradigm of pacing

    Get PDF
    Despite continuous technological developments, transvenous pacemakers (PM) are still associated with significant immediate and long-term complications, mostly lead or pocket-related. Recent technological advances brought to the introduction in clinical practice of leadless PM for selected cohort of patients. These miniaturize devices are implanted through the femoral vein and advanced to the right ventricle, without leaving leads in place. Lack of upper extremity vascular access and/or high infective risk in patients requiring VVI pacing are the most common indications to leadless PM. The recently introduced MICRA AV leadless PM also allows ventricular synchronization through mechanical sensing of atrial contraction waves, thus solving the problem of AV synchronization. This review will discuss and summarize available clinical evidence on leadless PM, their performance compared to transvenous devices, current applications and future perspectives

    Coexistence of Vagus Nerve Stimulation and Epicardial Implantable Cardioverter-Defibrillator System, Possible Interference: A Case Report and Systematic Review of the Literature

    Get PDF
    Vagus nerve stimulation (VNS) is an effective treatment for drug-resistant epilepsies in adults [1] and children [2]. Although VNS is generally well tolerated, rare cases of severe bradycardia..

    Longevity of Replaced ICD/CRT-D

    Get PDF
    Longevity of Replaced ICD/CRT-D Introduction The longevity of defibrillators (ICD) is extremely important from both a clinical and economic perspective. We studied the reasons for device replacement, the longevity of removed ICD, and the existence of possible factors associated with shorter service life. Methods and Results Consecutive patients who underwent ICD replacement from March 2013 to May 2015 in 36 Italian centers were included in this analysis. Data on replaced devices were collected. A total of 953 patients were included in this analysis. In 813 (85%) patients the reason for replacement was battery depletion, while 88 (9%) devices were removed for clinical reasons and the remaining 52 because of system failure (i.e., lead or ICD generator failure or a safety advisory indication). The median service life was 5.9 years (25th–75th percentile, 4.9–6.9) for single- and dual-chamber ICD and 4.9 years (25th–75th percentile, 4.0–5.7) for CRT-D. On multivariate analysis, the factors CRT-D device, SC/DC ICD generator from Biotronik, percentage of ventricular pacing, and the occurrence of a system failure were positively associated with a replacement procedure. By contrast, the device from Boston Scientific was an independent protective factor against replacement. Considerable differences were seen in battery duration in both ICD and CRT-D. Specifically, Biotronik devices showed the shortest longevity among ICD and Boston Scientific showed the longest longevity among CRT-D (log-rank test, P < 0.001 for pairwise comparisons). Conclusion Several factors were associated with shorter service life of ICD devices: CRT-D, occurrence of system failure and percentage of ventricular pacing. Our results confirmed significant differences among manufacturers

    Successful ventricular tachycardia radioablation in a patient with previous chemical pleurodesis: A case report

    Get PDF
    IntroductionStereotactic arrhythmia radioablation (STAR) is a novel technique for the ablation of ventricular tachycardia in patients with contraindications to standard procedures, i.e., radiofrequency ablation.Case presentationWe report the case of a 73-year-old man with non-ischemic dilated cardiomyopathy and recurrent VT episodes. Electroanatomic mapping showed VT prevalently of epicardial origin, but direct epicardial access through subxyphoid puncture could not be performed due to pleuropericardial adhesions from a past history of chemical pleurodesis. STAR was performed, with no VT recurrence at 6 months follow-up.ConclusionsPrevious experiences with STAR have demonstrated its importance in the management of patients with refractory VT in whom other ablation strategies were not successful. Our case report highlights the use of STAR as a second choice in a patient with an unfavorable VT anatomical location and technical limitations to an optimal radiofrequency ablation. Moreover, it confirms STAR's effectiveness in the ablation of complex transmural lesions, which are more often associated with non-ischemic structural heart disease

    Cardiovascular implantable electronic device infection: delayed vs standard FDG PET-CT imaging

    No full text
    Positron emission tomography-computed tomography (PET-CT) with (18)F-fluorodeoxyglucose (FDG) has emerged as a rapidly evolving diagnostic tool for infectious diseases. However, the optimal imaging time in this clinical setting is not clear yet. The aim of this study is to investigate whether delayed (3 hours) FDG PET-CT could increase the diagnostic accuracy of this technique compared to standard (1 hour) imaging in the detection of septic foci involving the pocket and/or pacing leads in patients with suspected cardiovascular implantable electronic device (CIED) infection scheduled for device removal. METHODS AND RESULTS: Twenty-seven patients underwent standard and delayed imaging. PET-CT results were compared to bacteriological cultures after CIED removal. Fifteen controls free of infection underwent PET-CT imaging as part of investigation of malignancy. The diagnostic accuracy of delayed imaging was significantly higher than 1-hour scan for lead infection (70% vs 51%, P = .024). No significant difference was found between standard and delayed diagnostic accuracy for pocket or device infection. Semi-quantitative analysis showed that mean pocket and lead target-to-background ratio were significantly higher on delayed compared to standard imaging (3.7 \ub1 1.9 vs 1.6 \ub1 1.1, P = .0002; 3.0 \ub1 1.3 vs 0.7 \ub1 1.0, P = .01). CONCLUSIONS: Delayed FDG PET-CT imaging should be considered at least in patients with negative 1-hour scan and founded suspicion of pacing lead infection

    Mid-Term Outcome of Ventricular Arrhythmias Catheter Ablation in Patients with Chronic Coronary Total Occlusion Compared to Ischemic and Non-Ischemic Patients

    No full text
    Chronic coronary total occlusions (CTO) are considered an emerging predictor of ventricular arrhythmias (VAs), but currently there are few data on arrhythmic outcomes in patients affected by CTO undergoing radiofrequency catheter ablation of VAs. This study sought to evaluate the impact of unrevascularized CTO on the recurrence of VAs after catheter ablation. This was a single-center retrospective study enrolling 120 patients between 2015 and 2020. All patients were admitted for ventricular tachycardia (VT) or high premature ventricular contractions burden (&gt;25% detected by Holter ECG), without evidence of acute coronary syndrome; they underwent coronary angiography, electrophysiology (EP) study, and three-dimensional electroanatomic mapping (3D-EAM) followed by VAs ablation. Twenty-eight patients (23%) of 120 patients showed CTO at coronary angiography. At baseline, the CTO group presented with higher prevalence of hypertension, chronic renal disease, systolic ventricular dysfunction, secondary prevention ICD implantation, and higher rate of LAVA by 3D-EAM compared with the non-CTO group. At a median follow-up of 15 months (range 1-96 months) after catheter ablation, the only independent predictor of VAs recurrence was the presence of moderate to severe left ventricular (LV) dysfunction. Therefore, the presence of CTO does not predict VAs recurrence after catheter ablation, which is instead predicted by LV dysfunction

    Pregnancy outcome and left ventricular ejection fraction in women with history of myocardial infarction

    No full text
    It is well known that cardiovascular diseases are the primary cause of morbidity and mortality worldwide. In consequence of AMI, there is a major loss of cardiomyocytes, which can lead to a variable grade of cardiac failure. AMI is uncommon in women during fertile age, but a pregnancy can occur after the cardiovascular event, due to improvement of maternal cares and increased maternal age. We would speculate on the possible positive role of pregnancy on damaged cardiomyocytes in women who had suffered from acute myocardial infarction (AMI). In particular, in a small series of cases we observed an improvement of the left ventricular ejection fraction (LVEF) after delivery if compared to that prior pregnancy
    • …
    corecore