55 research outputs found

    鏡視下足関節固定術で使用される中空海綿骨螺子による圧着圧の比較

    Get PDF
    Background: When performing arthroscopic ankle arthrodesis for end-stage ankle arthritis, internal fixation is performed using bone screws after appropriate preparation. However, optimal characteristics of bone screws have not been examined in terms of pressure force. Objective comparisons of bone-screw performance may provide information on procedures for arthroscopic ankle arthrodesis. The study objectives were to determine whether it was possible to measure compressive force changes using the newly developed device and to infer all screw characteristics from measurement results when used in actual surgeries. In addition, we performed experiments on cadavers to verify whether the experimental results could be applied to the joints of living subjects. Methods: Three types of screws (S1, S2, and S3) were inserted into the unique measurement device, and the changes in pressure were measured for each 45° turn. Changes in pressure and maximum pressure force were recorded after the application of the screws. After reaching the maximum pressure in the simulated bone, further screw rotations were accompanied by a gradual pressure decrease to 0 MPa. We also measured pressure changes in a similar manner by inserting a miniature pressure sensor into the talocrural joints of cadavers. Results: The mean maximum pressure ± standard deviation for S1, S2, and S3 were 0.832 ± 0.164 MPa, 0.434 ± 0.116 MPa, and 0.414 ± 0.127 MPa, respectively. Pressure slopes to the maximum did not significantly differ between the screws in the simulated bone, and a subsequent pressure decrease to 0 MPa was significantly more rapid for S1 than for S2 and S3. Although pressure failure after the overtightening of screws was only observed in the simulated bone, patterns of pressure vs. rotation angle were similar in simulated and cadaveric bones. The pressure profile characteristics of three different screw types were determined. Conclusions: We were able to measure the compressive force changes using the newly developed device when the screws were inserted. On the basis of the measurement results, we were able to infer the characteristics of all screws when used in actual surgery.博士(医学)・乙第1403号・平成29年6月28日Copyright © The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated

    Solitary Asymptomatic Thyroid Metastasis from Hepatocellular Carcinoma Detected by FDG-PET/CT

    Get PDF
    Thyroid metastases from hepatocellular carcinoma (HCC) seldom occur and are often difficult to diagnose because of their asymptomatic clinical course. We evaluated a very rare case of solitary thyroid metastasis from HCC that showed high uptake of fluorine-18 fluorodeoxyglucose (FDG), when imaged using fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT). The patient was a 74-year-old man and presented with a remarkably elevated des-gamma-carboxy prothrombin level of 1,157 mAU/ml 22 months after hepatic lobectomy. FDG-PET/CT imaging revealed a hypodense tumor with high FDG uptake, with a maximum standardized uptake value of 5.2 in the thyroid left lobe. Solitary thyroid metastasis from HCC was suspected and subsequent fine needle aspiration did indeed reveal HCC. The patient received left thyroidectomy with left regional lymph node dissection. Two months after left thyroidectomy, contrast-enhanced computed tomography showed local recurrence, and the patient received ongoing radiotherapy treatment. To our knowledge, the present study is the first to demonstrate the feasibility of FDG-PET/CT in the diagnosis and management of clinically diagnosed, asymptomatic, solitary thyroid metastasis from HCC

    Transport of estrone 3-sulfate mediated by organic anion transporter OATP4C1: estrone 3-sulfate binds to the different recognition site for digoxin in OATP4C1.

    Get PDF
    Human organic anion transporter OATP4C1 is a member of the OATP family predominantly expressed in the kidney, and contributes to the renal secretion of digoxin. However, little is known about the characteristics of OATP4C1-madiated transport. We examined the transport of estrone 3-sulfate, which is known as a substrate for other OATPs, by OATP4C1-expressing cells. Estrone 3-sulfate was efficiently transported by OATP4C1. The Michaelis-Menten constant for estrone 3-sulfate uptake by OATP4C1 was 26.6+/-4.9 microM. Transport of estrone 3-sulfate was significantly inhibited by triiodothyronine, chenodeoxycholic acid, bromosulfophtalein, and cyclosporine, whereas known substrates of OATP4C1, digoxin and ouabain, did not change OATP4C1-mediated transport. We further examined the mutual inhibition study between estrone 3-sulfate and digoxin. Digoxin partially inhibited the estrone 3-sulfate transport, and estrone 3-sulfate did not significantly inhibit digoxin transport. The estimated IC(50) value of digoxin for OATP4C1-mediated estrone 3-sulfate transport was 119 microM. This value is not comparable with the Michaelis-Menten constant for digoxin uptake by OATP4C1 (7.8 microM) reported by Mikkaichi et al.(1)) In conclusion, we found that estrone 3-sulfate is a novel substrate for OATP4C1. Moreover, our results indicate that estrone 3-sulfate does not bind to the recognition site for digoxin in OATP4C1

    Comparison of compressive forces caused by various cannulated cancellous screws used in arthroscopic ankle arthrodesis.

    No full text
    Background: When performing arthroscopic ankle arthrodesis for end-stage ankle arthritis, internal fixation is performed using bone screws after appropriate preparation. However, optimal characteristics of bone screws have not been examined in terms of pressure force. Objective comparisons of bone-screw performance may provide information on procedures for arthroscopic ankle arthrodesis. The study objectives were to determine whether it was possible to measure compressive force changes using the newly developed device and to infer all screw characteristics from measurement results when used in actual surgeries. In addition, we performed experiments on cadavers to verify whether the experimental results could be applied to the joints of living subjects. Methods: Three types of screws (S1, S2, and S3) were inserted into the unique measurement device, and the changes in pressure were measured for each 45° turn. Changes in pressure and maximum pressure force were recorded after the application of the screws. After reaching the maximum pressure in the simulated bone, further screw rotations were accompanied by a gradual pressure decrease to 0 MPa. We also measured pressure changes in a similar manner by inserting a miniature pressure sensor into the talocrural joints of cadavers. Results: The mean maximum pressure ± standard deviation for S1, S2, and S3 were 0.832 ± 0.164 MPa, 0.434 ± 0.116 MPa, and 0.414 ± 0.127 MPa, respectively. Pressure slopes to the maximum did not significantly differ between the screws in the simulated bone, and a subsequent pressure decrease to 0 MPa was significantly more rapid for S1 than for S2 and S3. Although pressure failure after the overtightening of screws was only observed in the simulated bone, patterns of pressure vs. rotation angle were similar in simulated and cadaveric bones. The pressure profile characteristics of three different screw types were determined. Conclusions: We were able to measure the compressive force changes using the newly developed device when the screws were inserted. On the basis of the measurement results, we were able to infer the characteristics of all screws when used in actual surgery.博士(医学)・乙第1403号・平成29年6月28日Copyright © The Author(s). 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.identifier:Journal of Orthopaedic Surgery and Research Vol.12 Article No.7 (2017 Jan)identifier:1749799Xidentifier:http://ginmu.naramed-u.ac.jp/dspace/handle/10564/3349identifier:Journal of Orthopaedic Surgery and Research, 12: Article No.

    Gateway Vectors for Simultaneous Detection of Multiple Protein-Protein Interactions in Plant Cells Using Bimolecular Fluorescence Complementation.

    Get PDF
    Bimolecular fluorescence complementation (BiFC) is widely used to detect protein-protein interactions, because it is technically simple, convenient, and can be adapted for use with conventional fluorescence microscopy. We previously constructed enhanced yellow fluorescent protein (EYFP)-based Gateway cloning technology-compatible vectors. In the current study, we generated new Gateway cloning technology-compatible vectors to detect BiFC-based multiple protein-protein interactions using N- and C-terminal fragments of enhanced cyan fluorescent protein (ECFP), enhanced green fluorescent protein (EGFP), and monomeric red fluorescent protein (mRFP1). Using a combination of N- and C-terminal fragments from ECFP, EGFP and EYFP, we observed a shift in the emission wavelength, enabling the simultaneous detection of multiple protein-protein interactions. Moreover, we developed these vectors as binary vectors for use in Agrobacterium infiltration and for the generate transgenic plants. We verified that the binary vectors functioned well in tobacco cells. The results demonstrate that the BiFC vectors facilitate the design of various constructions and are convenient for the detection of multiple protein-protein interactions simultaneously in plant cells
    corecore