26 research outputs found
Interventional MRI: Tapering improves the distal sensitivity of the loopless antenna
The "loopless antenna" is an interventional MRI detector consisting of a tuned coaxial cable and an extended inner conductor or "whip". A limitation is the poor sensitivity afforded at, and immediately proximal to, its distal end, which is exacerbated by the extended whip length when the whip is uniformly insulated. It is shown here that tapered insulation dramatically improves the distal sensitivity of the loopless antenna by pushing the current sensitivity toward the tip. The absolute signal-to-noise ratio is numerically computed by the electromagnetic method-of-moments for three resonant 3-T antennae with no insulation, uniform insulation, and with linearly tapered insulation. The analysis shows that tapered insulation provides an ∼400% increase in signal-to-noise ratio in trans-axial planes 1 cm from the tip and a 16-fold increase in the sensitive area as compared to an equivalent, uniformly insulated antenna. These findings are directly confirmed by phantom experiments and by MRI of an aorta specimen. The results demonstrate that numerical electromagnetic signal-tonoise ratio analysis can accurately predict the loopless detector's signal-to-noise ratio and play a central role in optimizing its design. The manifold improvement in distal signal-to-noise ratio afforded by redistributing the insulation should improve the loopless antenna's utility for interventional MRI. © 2010 Wiley-Liss, Inc
Absolute temperature monitoring using RF radiometry in the MRI scanner
Temperature detection using microwave radiometry has proven value for noninvasively measuring the absolute temperature of tissues inside the body. However, current clinical radiometers operate in the gigahertz range, which limits their depth of penetration. We have designed and built a noninvasive radiometer which operates at radio frequencies (64 MHz) with ∼100-kHz bandwidth, using an external RF loop coil as a thermal detector. The core of the radiometer is an accurate impedance measurement and automatic matching circuit of 0.05 Ω accuracy to compensate for any load variations. The radiometer permits temperature measurements with accuracy of ±0.1°K, over a tested physiological range of 28°C-40 °C in saline phantoms whose electric properties match those of tissue. Because 1.5 T magnetic resonance imaging (MRI) scanners also operate at 64 MHz, we demonstrate the feasibility of integrating our radiometer with an MRI scanner to monitor RF power deposition and temperature dosimetry, obtaining coarse, spatially resolved, absolute thermal maps in the physiological range. We conclude that RF radiometry offers promise as a direct, noninvasive method of monitoring tissue heating during MRI studies and thereby providing an independent means of verifying patient-safe operation. Other potential applications include titration of hyper- and hypo-therapies. © 2006 IEEE
Functional characterization of a melon alcohol acyl-transferase gene family involved in the biosynthesis of ester volatiles. Identification of the crucial role of a threonine residue for enzyme activity
Volatile esters, a major class of compounds contributing to the aroma of many fruit, are synthesized by
alcohol acyl-transferases (AAT). We demonstrate here that, in Charentais melon (Cucumis melo var.
cantalupensis), AAT are encoded by a gene family of at least four members with amino acid identity ranging
from 84% (Cm-AAT1/Cm-AAT2) and 58% (Cm-AAT1/Cm-AAT3) to only 22% (Cm-AAT1/Cm-AAT4).
All encoded proteins, except Cm-AAT2, were enzymatically active upon expression in yeast and show
differential substrate preferences. Cm-AAT1 protein produces a wide range of short and long-chain acyl
esters but has strong preference for the formation of E-2-hexenyl acetate and hexyl hexanoate. Cm-AAT3
also accepts a wide range of substrates but with very strong preference for producing benzyl acetate.
Cm-AAT4 is almost exclusively devoted to the formation of acetates, with strong preference for cinnamoyl
acetate. Site directed mutagenesis demonstrated that the failure of Cm-AAT2 to produce volatile esters is
related to the presence of a 268-alanine residue instead of threonine as in all active AAT proteins. Mutating
268-A into 268-T of Cm-AAT2 restored enzyme activity, while mutating 268-T into 268-A abolished
activity of Cm-AAT1. Activities of all three proteins measured with the prefered substrates sharply increase
during fruit ripening. The expression of all Cm-AAT genes is up-regulated during ripening and inhibited in
antisense ACC oxidase melons and in fruit treated with the ethylene antagonist 1-methylcyclopropene
(1-MCP), indicating a positive regulation by ethylene. The data presented in this work suggest that the
multiplicity of AAT genes accounts for the great diversity of esters formed in melon
The Cholecystectomy As A Day Case (CAAD) Score: A Validated Score of Preoperative Predictors of Successful Day-Case Cholecystectomy Using the CholeS Data Set
Background
Day-case surgery is associated with significant patient and cost benefits. However, only 43% of cholecystectomy patients are discharged home the same day. One hypothesis is day-case cholecystectomy rates, defined as patients discharged the same day as their operation, may be improved by better assessment of patients using standard preoperative variables.
Methods
Data were extracted from a prospectively collected data set of cholecystectomy patients from 166 UK and Irish hospitals (CholeS). Cholecystectomies performed as elective procedures were divided into main (75%) and validation (25%) data sets. Preoperative predictors were identified, and a risk score of failed day case was devised using multivariate logistic regression. Receiver operating curve analysis was used to validate the score in the validation data set.
Results
Of the 7426 elective cholecystectomies performed, 49% of these were discharged home the same day. Same-day discharge following cholecystectomy was less likely with older patients (OR 0.18, 95% CI 0.15–0.23), higher ASA scores (OR 0.19, 95% CI 0.15–0.23), complicated cholelithiasis (OR 0.38, 95% CI 0.31 to 0.48), male gender (OR 0.66, 95% CI 0.58–0.74), previous acute gallstone-related admissions (OR 0.54, 95% CI 0.48–0.60) and preoperative endoscopic intervention (OR 0.40, 95% CI 0.34–0.47). The CAAD score was developed using these variables. When applied to the validation subgroup, a CAAD score of ≤5 was associated with 80.8% successful day-case cholecystectomy compared with 19.2% associated with a CAAD score >5 (p < 0.001).
Conclusions
The CAAD score which utilises data readily available from clinic letters and electronic sources can predict same-day discharges following cholecystectomy
The location decision of the multinational corporation and the national tax accounting system The case of Egypt
SIGLEAvailable from British Library Document Supply Centre- DSC:DX91070 / BLDSC - British Library Document Supply CentreGBUnited Kingdo
RF radiometery sensor sensitivity and detection profile
Temperature sensing using microwave radiometry has proven value for non-invasively measuring the absolute temperature of tissues inside the human body. However, current clinical radiometers operate in GHz or infrared frequency ranges; this limits their depth of penetration since the human body is not "transparent" at these frequencies. To address this problem, we have previously designed and built an advanced, near-field radiometer operating at VHF frequencies (64MHz) with a ∼100 KHz bandwidth. The radiometer has performed accurate temperature measurements to within ±0.1°C, over a tested physiological range of 28-40°C in saline phantoms whose electric properties match those of human tissue. In this work we analyze radiofrequency (RF) coil designs suitable for RF Radiometry. We investigate the coil profile sensitivity to look where temperature information is coming from and the depth of penetration associated with the receiver used. We also look into the virtues of using multi-turn coils versus single loop coils. We conclude that by using multi-turn coils the received noise signal is more sensitive to sample noise and temperature can be estimated more accurately especially with the use of smaller receivers. © 2008 IEEE
Study on adsorption of methanol onto carbon based adsorbents
10.1016/j.ijrefrig.2009.06.011International Journal of Refrigeration3271579-1586IJRF