11 research outputs found

    Seismic Retrofitting: Reinforced Concrete (RC) shear wall versus Reinforcement of RC element by Carbon Fiber Reinforced Polymer (CFRP) using PUSHOVER analysis

    No full text
    Seismic retrofitting of constructions vulnerable to earthquakes is a current problem of great political and social relevance. During the last sixty years, moderate to severe earthquakes have occurred in Morocco (specifically in Agadir 1960 and Hoceima 2004). Such events have clearly shown the vulnerability of the building stock in particular and of the built environment in general. Hence, it is very much essential to retrofit the vulnerable building to cope up for the next damaging earthquake. In this paper, the focus will be on a comparative study between two techniques of seismic retrofitting, the first one is a reinforcement using carbon fiber reinforced polymer (CFRP) applied to RC elements by bonding , and the second one is a reinforcement with a shear wall. For this study, we will use a non-linear static analysis -also known as Pushover analysis - on a reinforced concrete structure consisting of beams and columns, and composed from eight storey with a gross area of 240 m², designed conforming to the Moroccan Seismic code[1]

    Seismic Retrofitting: Reinforced Concrete (RC) shear wall versus Reinforcement of RC element by Carbon Fiber Reinforced Polymer (CFRP) using PUSHOVER analysis

    No full text
    Seismic retrofitting of constructions vulnerable to earthquakes is a current problem of great political and social relevance. During the last sixty years, moderate to severe earthquakes have occurred in Morocco (specifically in Agadir 1960 and Hoceima 2004). Such events have clearly shown the vulnerability of the building stock in particular and of the built environment in general. Hence, it is very much essential to retrofit the vulnerable building to cope up for the next damaging earthquake. In this paper, the focus will be on a comparative study between two techniques of seismic retrofitting, the first one is a reinforcement using carbon fiber reinforced polymer (CFRP) applied to RC elements by bonding , and the second one is a reinforcement with a shear wall. For this study, we will use a non-linear static analysis -also known as Pushover analysis - on a reinforced concrete structure consisting of beams and columns, and composed from eight storey with a gross area of 240 m², designed conforming to the Moroccan Seismic code[1]

    Solution of internal erosion equations by asymptotic expansion

    No full text
    One dimensional coupled soil internal erosion and consolidation equations are considered in this work for the special case of well determined sand and clay mixtures with a small proportion of clay phase. An enhanced modelling of the effect of erosion on elastic soil behavior was introduced through damage mechanics concepts. A modified erosion law was proposed. The erosion phenomenon taking place inside the soil was shown to act like a perturbation affecting the classical soil consolidation equation. This interpretation has enabled considering an asymptotic expansion of the coupled erosion consolidation equations in terms of a perturbation parameter linked to the maximum expected internal erosion. A robust analytical solution was obtained via direct integration of equations at order zero and an adequate finite difference scheme that was applied at order one

    Reinforcement of RC structure by carbon fibers

    No full text
    In recent years, rehabilitation has been the subject of extensive research due to the increased spending on building maintenance work and restoration of built works. In all cases, it is essential to carry out methods of reinforcement or maintenance of structural elements, following an inspection analysis and methodology of a correct diagnosis. This research focuses on the calculation of the necessary reinforcement sections of carbon fiber for structural elements with reinforced concrete in order to improve their load bearing capacity and rigidity. The different results obtained reveal a considerable gain in resistance and deformation capacity of reinforced sections without significant increase in the weight of the rehabilitated elements

    Reinforcement of RC structure by carbon fibers

    No full text
    In recent years, rehabilitation has been the subject of extensive research due to the increased spending on building maintenance work and restoration of built works. In all cases, it is essential to carry out methods of reinforcement or maintenance of structural elements, following an inspection analysis and methodology of a correct diagnosis. This research focuses on the calculation of the necessary reinforcement sections of carbon fiber for structural elements with reinforced concrete in order to improve their load bearing capacity and rigidity. The different results obtained reveal a considerable gain in resistance and deformation capacity of reinforced sections without significant increase in the weight of the rehabilitated elements

    Can land use changes alter carbon, nitrogen and major ion transport in subtropical brazilian streams? Modificações no uso da terra podem alterar o transporte fluvial de carbono, nitrogênio e íons maiores?

    Get PDF
    Several studies in tropical watersheds have evaluated the impact of urbanization and agricultural practices on water quality. In Brazil, savannas (known regionally as Cerrados) represent 23% of the country's surface, representing an important share to the national primary growth product, especially due to intense agriculture. The purpose of this study is to present a comprehensive evaluation, on a yearly basis, of carbon, nitrogen and major ion fluxes in streams crossing areas under different land use (natural vegetation, sugar cane and eucalyptus) in a savanna region of SE Brazil. Eucalyptus and sugar cane alter the transport of the investigated elements in small watersheds. The highest concentration of all parameters (abiotic parameters, ions, dissolved organic carbon DOC - and dissolved inorganic carbon - DIC) were found in Sugar Cane Watersheds (SCW). The observed concentrations of major cations in Eucalyptus Watersheds (EW) (Mg, Ca, K, Na), as well as DIN and DOC, were found frequently to be intermediate values between those of Savanna Watersheds (SW) and SCW, suggesting a moderate impact of eucalyptus plantations on the streamwater. Same trends were found in relation to ion and nutrient fluxes, where the higher values corresponded to SCW. It is suggested that sugar cane plantations might be playing an important role in altering the chemistry of water bodies.<br>Diversos estudos têm sido desenvolvidos em bacias de drenagem tropicais no intuito de avaliar o impacto da urbanização e das práticas agrícolas na qualidade dos corpos d'água. No Brasil, as savanas (conhecidas regionalmente como Cerrado) representam 23% do território brasileiro, sendo uma região importante no crescimento nacional, especialmente devido às intensas atividades agrícolas. A finalidade deste trabalho é apresentar uma avaliação dos fluxos de carbono, nitrogênio e principais íons em córregos com diferentes usos do solo (vegetação, cana de açúcar e eucalipto) em uma região de Cerrado, SE Brasil. A cana de açúcar e o eucalipto alteram o transporte dos elementos investigados nessas pequenas bacias de drenagem. As concentrações mais elevadas de todos os parâmetros analisados (parâmetros abióticos, íons, carbono orgânico dissolvido e carbono inorgânico dissolvido) foram encontradas na bacia de cana de açúcar (SCW). As concentrações observadas para os cátions na bacia do eucalipto (EW) (Mg, Ca, K, Na), assim como Carbono Inorgânico Dissolvido (CID) e Carbono Orgânico Dissolvido (COD), apresentaram valores intermediários entre as bacias do Cerrado e da cana de açúcar, sugerindo um impacto moderado dessa plantação aos corpos d'água. Mesma tendência foi observada para os fluxos de íons e nutrientes, sendo, novamente, os maiores valores encontrados na bacia de cana-de-açúcar. Os autores sugerem que o cultivo da cana de açúcar representa um importante fator na modificação da química de pequenas bacias de drenagem

    Spatial Representations in the Rat: Case Study or Perspective on Episodic Memory?

    No full text

    Stock Plant Physiological Factors Affecting Growth and Morphogenesis

    No full text
    corecore