6,425 research outputs found

    Angle-dependence of the Hall effect in HgBa2CaCu2O6 thin films

    Full text link
    Superconducting compounds of the family Hg-Ba-Ca-Cu-O have been the subject of intense study since the current record-holder for the highest critical temperature of a superconductor belongs to this class of materials. Thin films of the compound with two adjacent copper-oxide layers and a critical temperature of about 120 K were prepared by a two-step process that consists of the pulsed-laser deposition of precursor films and the subsequent annealing in mercury-vapor atmosphere. Like some other high-temperature superconductors, Hg-Ba-Ca-Cu-O exhibits a specific anomaly of the Hall effect, a double-sign change of the Hall coefficient close to the superconducting transition. We have investigated this phenomenon by measurements of the Hall effect at different angles between the magnetic field direction and the crystallographic c-axis. The results concerning the upper part of the transition, where the first sign change occurs, are discussed in terms of the renormalized fluctuation model for the Hall conductivity, adapted through the field rescaling procedure in order to take into account the arbitrary orientation of the magnetic field.Comment: to be published in Phys. Rev.

    First results of the ROSEBUD Dark Matter experiment

    Full text link
    Rare Objects SEarch with Bolometers UndergrounD) is an experiment which attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through their elastic scattering off Al and O nuclei. It consists of three small sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a dilution refrigerator operating at 20 mK in the Canfranc Underground Laboratory. We report in this paper the results of several runs (of about 10 days each) with successively improved energy thresholds, and the progressive background reduction obtained by improvement of the radiopurity of the components and subsequent modifications in the experimental assembly, including the addition of old lead shields. Mid-term plans and perspectives of the experiment are also presented.Comment: 14 pages, 8 figures, submitted to Astroparticle Physic

    Performance of a Tungsten-Cerium Fluoride Sampling Calorimeter in High-Energy Electron Beam Tests

    Full text link
    A prototype for a sampling calorimeter made out of cerium fluoride crystals interleaved with tungsten plates, and read out by wavelength-shifting fibres, has been exposed to beams of electrons with energies between 20 and 150 GeV, produced by the CERN Super Proton Synchrotron accelerator complex. The performance of the prototype is presented and compared to that of a Geant4 simulation of the apparatus. Particular emphasis is given to the response uniformity across the channel front face, and to the prototype's energy resolution.Comment: 6 pages, 6 figures, Submitted to NIM

    Ratio of Hadronic Decay Rates of J\psi and \psi(2S) and the \rho\pi Puzzle

    Full text link
    The so-called \rho\pi puzzle of J\psi and \psi(2S) decays is examined using the experimental data available to date. Two different approaches were taken to estimate the ratio of J\psi and \psi(2S) hadronic decay rates. While one of the estimates could not yield the exact ratio of \psi(2S) to J\psi inclusive hadronic decay rates, the other, based on a computation of the inclusive ggg decay rate for \psi(2S) (J\psi) by subtracting other decay rates from the total decay rate, differs by two standard deviations from the naive prediction of perturbative QCD, even though its central value is nearly twice as large as what was naively expected. A comparison between this ratio, upon making corrections for specific exclusive two-body decay modes, and the corresponding experimental data confirms the puzzles in J\psi and \psi(2S) decays. We find from our analysis that the exclusively reconstructed hadronic decays of the \psi(2S) account for only a small fraction of its total decays, and a ratio exceeding the above estimate should be expected to occur for a considerable number of the remaining decay channels. We also show that the recent new results from the BES experiment provide crucial tests of various theoretical models proposed to explain the puzzle.Comment: 8 pages, no figure, 4 table

    Post-transplant recurrence of steroid resistant nephrotic syndrome in children: the Italian experience

    Get PDF
    Background: Steroid resistant nephrotic syndrome (SRNS) is a frequent cause of end stage renal disease in children and post-transplant disease recurrence is a major cause of graft loss. Methods: We identified all children with SRNS who underwent renal transplantation in Italy, between 2005 and 2017. Data were retrospectively collected for the presence of a causative gene mutation, sex, histology, duration of pre-transplant dialysis, age at onset and transplant, HLA matching, recurrence, therapy for recurrence, and graft survival. Results: 101 patients underwent a first and 22 a second renal transplant. After a median follow-up of 58.5 months, the disease recurred on the first renal transplant in 53.3% of patients with a non-genetic and none with a genetic SRNS. Age at transplant > 9 years and the presence of at least one HLA-AB match were independent risk factors for recurrence. Duration of dialysis was longer in children with relapse, but did not reach statistical significance. Overall, 24% of patients lost the first graft, with recurrence representing the commonest cause. Among 22 patients who underwent a second transplant, 5 suffered of SRNS recurrence. SRNS relapsed in 5/9 (55%) patients with disease recurrence in their first transplant and 2 of them lost the second graft. Conclusions: Absence of a causative mutation represents the major risk factor for post-transplant recurrence in children with SRNS, while transplant can be curative in genetic SRNS. A prolonged time spent on dialysis before transplantation has no protective effect on the risk of relapse and should not be encouraged. Retransplantation represents a second chance after graft loss for recurrence

    Has VZV epidemiology changed in Italy? Results of a seroprevalence study

    Get PDF
    The aim of the study was to evaluate if and how varicella prevalence has changed in Italy. In particular a seroprevalence study was performed, comparing it to similar surveys conducted in pre-immunization era. During 2013–2014, sera obtained from blood samples taken for diagnostic purposes or routine investigations were collected in collaboration with at least one laboratory/center for each region, following the approval of the Ethics Committee. Data were stratified by sex and age. All samples were processed in a national reference laboratory by an immunoassay with high sensitivity and specificity. Statutory notifications, national hospital discharge database and mortality data related to VZV infection were analyzed as well. A total of 3707 sera were collected and tested. In the studied period both incidence and hospitalization rates decreased and about 5 deaths per year have been registered. The seroprevalence decreased in the first year of life in subjects passively protected by their mother, followed by an increase in the following age classes. The overall antibody prevalence was 84%. The comparison with surveys conducted with the same methodology in 1996–1997 and 2003–2004 showed significant differences in age groups 1–19 y. The study confirms that in Italy VZV infection typically occurs in children. The impact of varicella on Italian population is changing. The comparison between studies performed in different periods shows a significant increase of seropositivity in age class 1–4 years, expression of vaccine interventions already adopted in some regions

    Search for fractionally charged particles in cosmic rays at large zenith angles

    Get PDF
    We have performed a single-particle search for fractional charge in cosmic rays having residual ranges at sea level >250 g/cm/sup 2/ concrete and zenith angles between 45/sup 0/ and 90/sup 0/. The detector is a hodoscope of 24 layers of plastic scintillator, eight layers of multiwire proportional chambers, and two layers of lucite Cherenkov counters. The acceptance of the instrument is 4.0 x 10/sup 3/ cm/sup 2/sr. An analysis of 3.5 x 10/sup 6/ triggers during a running time of 8 x 10/sup 5/ sec yields no particles with charge Q = (1/3) or Q = (2/3) and velocities greater than roughly-equal0.1c. We deduce an upper limit on the flux of fractionally charged particles of 8.5 x 10/sup -10/ (cm/sup 2/sr sec)/sup -1/ for relativistic Q = (1/3) and 7.6 x 10/sup -10/ (cm/sup 2/sr sec)/sup -1/ for Q = (2/3)
    • …
    corecore