168 research outputs found

    Ultrasound markers for prediction of complex gastroschisis and adverse outcome:longitudinal prospective nationwide cohort study

    Get PDF
    Contains fulltext : 220734.pdf (Publisher’s version ) (Open Access)OBJECTIVES: To identify antenatal ultrasound markers that can differentiate between simple and complex gastroschisis and assess their predictive value. METHODS: This was a prospective nationwide study of pregnancies with isolated fetal gastroschisis that underwent serial longitudinal ultrasound examination at regular specified intervals between 20 and 37 weeks' gestation. The primary outcome was simple or complex (i.e. involving bowel atresia, volvulus, perforation or necrosis) gastroschisis at birth. Fetal biometry (abdominal circumference and estimated fetal weight), the occurrence of polyhydramnios, intra- and extra-abdominal bowel diameters and the pulsatility index (PI) of the superior mesenteric artery (SMA) were assessed. Linear mixed modeling was used to compare the individual trajectories of cases with simple and those with complex gastroschisis, and logistic regression analysis was used to estimate the strength of association between the ultrasound parameters and outcome. RESULTS: Of 104 pregnancies with isolated fetal gastroschisis included, four ended in intrauterine death. Eighty-one (81%) liveborn infants with simple and 19 (19%) with complex gastroschisis were included in the analysis. We found no relationship between fetal biometric variables and complex gastroschisis. The SMA-PI was significantly lower in fetuses with gastroschisis than in healthy controls, but did not differentiate between simple and complex gastroschisis. Both intra- and extra-abdominal bowel diameters were larger in cases with complex, compared to those with simple, gastroschisis (P /= 97.7(th) percentile on at least three occasions, not necessarily on successive examinations, was associated with an increased risk of the fetus having complex gastroschisis (relative risk, 1.56 (95% CI, 1.02-2.10); P = 0.006; positive predictive value, 50.0%; negative predictive value, 81.4%). CONCLUSIONS: This large prospective longitudinal study found that intra-abdominal bowel dilatation when present repeatedly during fetal development can differentiate between simple and complex gastroschisis; however, the positive predictive value is low, and therefore the clinical usefulness of this marker is limited. (c) 2019 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology

    Palaeobiology, ecology, and distribution of stromatoporoid faunas in biostromes of the mid-Ludlow of Gotland

    Get PDF
    Six well exposed mid−Ludlow stromatoporoid−dominated reef biostromes in four localities from the Hemse Group in southeastern Gotland, Sweden comprise a stromatoporoid assemblage dominated by four species; Clathrodictyon mohicanum, “Stromatopora” bekkeri, Plectostroma scaniense, and Lophiostroma schmidtii. All biostromes investigated in this area (of approximately 30 km2) are interpreted to belong to a single faunal assemblage forming a dense accumulation of fossils that is probably the best exposed stromatoporoid−rich deposit of the Silurian. The results from this comprehensive study strengthen earlier interpretations of a combination of genetic and environmental control on growth−forms of the stromatoporoids. Growth styles are similar for stromatoporoids in all six biostromes. Differences in biostrome fabric are due to variations in the degree of disturbance by storms. The uniformity of facies and the widespread low−diversity fauna support the view that palaeoenvironmental conditions were similar across the area where these biostromes crop out, and promoted the extraordinary growth of stromatoporoids in this shallow shelf area

    Operation and Utilisation of the High Flux Reactor - Annual Report 2009

    Get PDF
    The High Flux Reactor (HFR) at Petten is managed by the Institute for Energy (IE) of the EC - DG JRC and operated by NRG who are also licence holder and responsible for commercial activities. The HFR operates at 45 MW and is of the tank-in-pool type, light water cooled and moderated. It is one of the most powerful multi-purpose materials testing reactors in the world and one of the world leaders in target irradiation for the production of medical radioisotopes.JRC.F-Institute for Energy and Transport (Petten

    Using three-dimensional ultrasound in predicting complex gastroschisis:A longitudinal, prospective, multicenter cohort study

    Get PDF
    Objective: To determine whether complex gastroschisis (ie, intestinal atresia, perforation, necrosis, or volvulus) can prenatally be distinguished from simple gastroschisis by fetal stomach volume and stomach-bladder distance, using three-dimensional (3D) ultrasound. Methods: This multicenter prospective cohort study was conducted in the Netherlands between 2010 and 2015. Of seven university medical centers, we included the four centers that performed longitudinal 3D ultrasound measurements at a regular basis. We calculated stomach volumes (n = 223) using Sonography-based Automated Volume Count. The shortest stomach-bladder distance (n = 241) was determined using multiplanar visualization of the volume datasets. We used linear mixed modelling to evaluate the effect of gestational age and type of gastroschisis (simple or complex) on fetal stomach volume and stomach-bladder distance. Results: We included 79 affected fetuses. Sixty-six (84%) had been assessed with 3D ultrasound at least once; 64 of these 66 were liveborn, nine (14%) had complex gastroschisis. With advancing gestational age, stomach volume significantly increased, and stomach-bladder distance decreased (both P <.001). The developmental changes did not differ significantly between fetuses with simple and complex gastroschisis, neither for fetal stomach volume (P =.85), nor for stomach bladder distance (P =.78). Conclusion: Fetal stomach volume and stomach-bladder distance, measured during pregnancy using 3D ultrasonography, do not predict complex gastroschisis

    Reference curves for the normal fetal small bowel and colon diameters; their usefulness in fetuses with suspected dilated bowel

    Get PDF
    Objectives: To establish reference curves of normal fetal small bowel and colon diameters and to assess the clinical applicability. Method: Serial longitudinal ultrasound examinations at 4-week intervals between 20 to 41 weeks of gestation in 39 low-risk fetuses. The largest loop of the small bowel and colon was identified. The bowel lumen short axis was measured. Linear mixed modeling was used to determine individual developmental trajectories. Twenty-eight fetuses with suspected bowel dilatation were analyzed relative to the reference curves. Results: Development of the small bowel and colon diameters was best described by a linear and cubic model, respectively. The intraobserver and interobserver concordance were >0.94. In cases with suspected bowel dilatation, normal fetal outcome occurred if the bowel dilatation was transient. Progressive increase of fetal bowel diameter was associated with pathology after birth. Cases with small bowel pathology had a z-score >8 after 25 weeks of gestation. Conclusion: We provided the first ultrasound reference curves for normal fetal small bowel and colon diameters. Progressive increase in the fetal bowel diameter z-score was highly predictive of intestinal abnormalities after birth. Longitudinal follow-up of dilated fetal bowel is important to distinguish normality from disease

    A prospective study on rapid exome sequencing as a diagnostic test for multiple congenital anomalies on fetal ultrasound

    Get PDF
    Objective: Conventional genetic tests (quantitative fluorescent-PCR [QF-PCR] and single nucleotide polymorphism-array) only diagnose ~40% of fetuses showing ultrasound abnormalities. Rapid exome sequencing (rES) may improve this diagnostic yield, but includes challenges such as uncertainties in fetal phenotyping, variant interpretation, incidental unsolicited findings, and rapid turnaround times. In this study, we implemented rES in prenatal care to increase diagnostic yield. Methods: We prospectively studied 55 fetuses. Inclusion criteria were: (a) two or more independent major fetal anomalies, (b) hydrops fetalis or bilateral renal cysts alone, or (c) one major fetal anomaly and a first-degree relative with the same anomaly. In addition to conventional genetic tests, we performed trio rES analysis using a custom virtual gene panel of ~3850 Online Mendelian Inheritance in Man (OMIM) genes. Results: We established a genetic rES-based diagnosis in 8 out of 23 fetuses (35%) without QF-PCR or array abnormalities. Diagnoses included MIRAGE (SAMD9), Zellweger (PEX1), Walker-Warburg (POMGNT1), Noonan (PTNP11), Kabuki (KMT2D), and CHARGE (CHD7) syndrome and two cases of Osteogenesis Imperfecta type 2 (COL1A1). In six cases, rES diagnosis aided perinatal management. The median turnaround time was 14 (range 8-20) days. Conclusion: Implementing rES as a routine test in the prenatal setting is challenging but technically feasible, with a promising diagnostic yield and significant clinical relevance

    Clinical accuracy of instrument-based SARS-CoV-2 antigen diagnostic tests:a systematic review and meta-analysis

    Get PDF
    Background: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests’ clinical accuracy. Methods: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. Results: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer’s instructions and those conducted differently, or between point-of-care and lab-based testing. Conclusion: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.</p

    Clinical accuracy of instrument-based SARS-CoV-2 antigen diagnostic tests:a systematic review and meta-analysis

    Get PDF
    Background: During the COVID-19 pandemic, antigen diagnostic tests were frequently used for screening, triage, and diagnosis. Novel instrument-based antigen tests (iAg tests) hold the promise of outperforming their instrument-free, visually-read counterparts. Here, we provide a systematic review and meta-analysis of the SARS-CoV-2 iAg tests’ clinical accuracy. Methods: We systematically searched MEDLINE (via PubMed), Web of Science, medRxiv, and bioRxiv for articles published before November 7th, 2022, evaluating the accuracy of iAg tests for SARS-CoV-2 detection. We performed a random effects meta-analysis to estimate sensitivity and specificity and used the QUADAS-2 tool to assess study quality and risk of bias. Sub-group analysis was conducted based on Ct value range, IFU-conformity, age, symptom presence and duration, and the variant of concern. Results: We screened the titles and abstracts of 20,431 articles and included 114 publications that fulfilled the inclusion criteria. Additionally, we incorporated three articles sourced from the FIND website, totaling 117 studies encompassing 95,181 individuals, which evaluated the clinical accuracy of 24 commercial COVID-19 iAg tests. The studies varied in risk of bias but showed high applicability. Of 24 iAg tests from 99 studies assessed in the meta-analysis, the pooled sensitivity and specificity compared to molecular testing of a paired NP swab sample were 76.7% (95% CI 73.5 to 79.7) and 98.4% (95% CI 98.0 to 98.7), respectively. Higher sensitivity was noted in individuals with high viral load (99.6% [95% CI 96.8 to 100] at Ct-level ≤ 20) and within the first week of symptom onset (84.6% [95% CI 78.2 to 89.3]), but did not differ between tests conducted as per manufacturer’s instructions and those conducted differently, or between point-of-care and lab-based testing. Conclusion: Overall, iAg tests have a high pooled specificity but a moderate pooled sensitivity, according to our analysis. The pooled sensitivity increases with lower Ct-values (a proxy for viral load), or within the first week of symptom onset, enabling reliable identification of most COVID-19 cases and highlighting the importance of context in test selection. The study underscores the need for careful evaluation considering performance variations and operational features of iAg tests.</p

    10-Year cardiovascular event risks for women who experienced hypertensive disorders in late pregnancy: the HyRAS study

    Get PDF
    ABSTRACT: BACKGROUND: Cardiovascular disease is the cause of death in 32% of women in the Netherlands. Prediction of an individual's risk for cardiovascular disease is difficult, in particular in younger women due to low sensitive and specific tests for these women. 10% to 15% of all pregnancies are complicated by hypertensive disorders, the vast majority of which develop only after 36 weeks of gestation. Preeclampsia and cardiovascular disease in later life show both features of "the metabolic syndrome" and atherosclerosis. Hypertensive disorders in pregnancy and cardiovascular disease may develop by common pathophysiologic pathways initiated by similar vascular risk factors. Vascular damage occurring during preeclampsia or gestational hypertension may contribute to the development of future cardiovascular disease, or is already present before pregnancy. At present clinicians do not systematically aim at the possible cardiovascular consequences in later life after a hypertensive pregnancy disorder at term. However, screening for risk factors after preeclampsia or gestational hypertension at term may give insight into an individual's cardiovascular risk profile. METHODS: Women with a history of preeclampsia or gestational hypertension will be invited to participate in a cohort study 2,5 years after delivery. Participants will be screened for established modifiable cardiovascular risk indicators. The primary outcome is the 10-year cardiovascular event risk. Secondary outcomes include differences in cardiovascular parameters, SNP's in glucose metabolism, and neonatal outcome. DISCUSSION: This study will provide evidence on the potential health gains of a modifiable cardiovascular risk factor screening program for women whose pregnancy was complicated by hypertension or preeclampsia. The calculation of individual 10-year cardiovascular event risks will allow identification of those women who will benefit from primary prevention by tailored interventions, at a relatively young age. Trail registration The HYPITAT trial is registered in the clinical trial register as ISRCTN08132825

    Ultrasound markers for prediction of complex gastroschisis and adverse outcome: longitudinal prospective nationwide cohort study

    Get PDF
    Objectives: To identify antenatal ultrasound markers that can differentiate between simple and complex gastroschisis and assess their predictive value. Methods: This was a prospective nationwide study of pregnancies with isolated fetal gastroschisis that underwent serial longitudinal ultrasound examination at regular specified intervals between 20 and 37 weeks' gestation. The primary outcome was simple or complex (i.e. involving bowel atresia, volvulus, perforation or necrosis) gastroschisis at birth. Fetal biometry (abdominal circumference and estimated fetal weight), the occurrence of polyhydramnios, intra- and extra-abdominal bowel diameters and the pulsatility index (PI) of the superior mesenteric artery (SMA) were assessed. Linear mixed modeling was used to compare the individual trajectories of cases with simple and those with complex gastroschisis, and logistic regression analysis was used to estimate the strength of association between the ultrasound parameters and outcome. Results: Of 104 pregnancies with isolated fetal gastroschisis included, four ended in intrauterine death. Eighty-one (81%) liveborn infants with simple and 19 (19%) with complex gastroschisis were included in the analysis. We found no relationship between fetal biometric variables and complex gastroschisis. The SMA-PI was significantly lower in fetuses with gastroschisis than in healthy controls, but did not differentiate between simple and complex gastroschisis. Both intra- and extra-abdominal bowel diameters were larger in cases with complex, compared to those with simple, gastroschisis (P < 0.001 and P < 0.005, respectively). The presence of intra-abdominal bowel diameter ≥ 97.7th percentile on at least three occasions, not necessarily on successive examinations, was associated with an increased risk of the fetus having complex gastroschisis (relative risk, 1.56 (95% CI, 1.02–2.10); P = 0.006; positive predictive value, 50.0%; negative predictive value, 81.4%). Conclusions: This large prospective longitudinal study found that intra-abdominal bowel dilatation when present repeatedly during fetal development can differentiate between simple and complex gastroschisis; however, the positive predictive value is low, and therefore the clinical usefulness of this marker is limited
    corecore