459 research outputs found

    Porous airfoil and process

    Get PDF
    A porous airfoil having venting cavities with contoured barrier walls, formed by a core piece, placed beneath a porous upper and lower surface area that stretches over the nominal chord of an airfoil is employed, to provide an airfoil configuration that becomes self-adaptive to very dissimilar flow conditions to thereby improve the lift and drag characteristics of the airfoil at both subcritical and supercritical conditions

    Carotenoid triplet state formation in Rhodobacter sphaeroides R-26 reaction centers exchanged with modified bacteriochlorophyll pigments and reconstituted with spheroidene

    Get PDF
    Triplet state electron paramagnetic resonance (EPR) experiments have been carried out at X-band on Rb. sphaeroides R-26 reaction centers that have been reconstituted with the carotenoid, spheroidene, and exchanged with 132-OH-Zn-bacteriochlorophyll a and [3-vinyl]-132-OH-bacteriochlorophyll a at the monomeric, lsquoaccessoryrsquo bacteriochlorophyll sites BA,B or with pheophytin a at the bacteriopheophytin sites HA,B. The primary donor and carotenoid triplet state EPR signals in the temperature range 95–150 K are compared and contrasted with those from native Rb. sphaeroides wild type and Rb. sphaeroides R-26 reaction centers reconstituted with spheroidene. The temperature dependencies of the EPR signals are strikingly different for the various samples. The data prove that triplet energy transfer from the primary donor to the carotenoid is mediated by the monomeric, BChlB molecule. Furthermore, the data show that triplet energy transfer from the primary donor to the carotenoid is an activated process, the efficiency of which correlates with the estimated triplet state energies of the modified pigments

    Building public-private partnerships for agricultural innovation:

    Get PDF
    Public-private partnerships are a new way of carrying out research and development (R&D) in Latin America's agricultural sector. These partnerships spur innovation for agricultural development and have various advantages over other institutional arrangements fostering R&D. This report summarizes the experiences of a research project that analyzed 125 public-private research partnerships (PPPs) in 12 Latin American countries. The analysis indicates that several types of partnerships have emerged in response to the various needs of the different partners. Nevertheless, public-private partnerships are not always the most appropriate mechanism by which to carry out R&D and foster innovation in agriculture. Sometimes, it is more efficient to organize research via participatory projects or through research contracts.Public-private partnerships, Agricultural innovations, Capacity strengthening, Agricultural research,

    Pharmacokinetic parameter sets of alfentanil revisited: optimal parameters for use in target controlled infusion and anaesthesia display systems

    Get PDF
    Background In open TCI and anaesthesia display systems, the choice of pharmacokinetic (PK) parameter sets of opioids is clinically relevant. Accuracy and bias of the PK models may be affected by administration mode and the co-administered hypnotic drug. We retrospectively evaluated the performance of eight PK parameter sets for alfentanil in two data sets (infusion and bolus application). Methods With the dosing history from two studies in orthopaedic patients anaesthetized with propofol or inhalation anaesthetics the alfentanil plasma concentration over time was calculated with eight PK parameter sets. Median absolute performance error (MDAPE), log accuracy, median performance error (MDPE), log bias, Wobble, and Divergence were computed. Mann-Whitney rank test with Bonferroni correction was used for comparison between bolus and infusion data, repeated measures analysis of variance on ranks was used for comparison among parameter sets. Results The parameters by Scott (original and weight adjusted) and Fragen had a MDAPE ≤30% and a median log accuracy <0.15 independent of the administration mode, while MDPE was within ±20% and log bias nearly within ±0.1, respectively. The sets by Maitre and Lemmens were within these limits only in the bolus data. All other parameter sets were outside these limits. Conclusions In healthy orthopaedic patients, the PK parameters by Scott and by Maitre were equally valid when alfentanil was given as repeated boluses. When given as infusion, the Maitre parameters were less accurate and subject to a significant bias. We cannot exclude that the difference between bolus and infusion is partially because of the different hypnotics use

    Preliminary Evaluation of Nonlinear Effects on TCA Flutter

    Get PDF
    The objective of this study is to investigate the effect of nonlinear aerodynamics, especially at high angles-of-attack with leading-edge separation, on the TCA flutter properties at transonic speeds. In order to achieve that objective, flutter simulations with Navier-Stokes CFD must be performed. To this end, time-marching Navier-Stokes solutions are computed for the TCA wing/body configuration at high angles-of-attack in transonic flight regimes. The approach is to perform non-linear flutter calculations on the TCA at two angles-of-attack, the first one being a case with attached flow (a=2.8 degrees) and the second one being a high angle-of-attack case with a wing leading edge vortex (a=12.11 degrees). Comparisons of the resulting histories and frequency damping information for both angles-of-attack will evaluate the impact of high-alpha aerodynamics on flutter

    Refined AFC-Enabled High-Lift System Integration Study

    Get PDF
    A prior trade study established the effectiveness of using Active Flow Control (AFC) for reducing the mechanical complexities associated with a modern high-lift system without sacrificing aerodynamic performance at low-speed flight conditions representative of takeoff and landing. The current technical report expands on this prior work in two ways: (1) a refined conventional high-lift system based on the NASA Common Research Model (CRM) is presented that is more representative of modern commercial transport aircraft in terms of stall characteristics and maximum Lift/Drag (L/D) ratios at takeoff and landing-approach flight conditions; and (2) the design trade space for AFC-enabled high-lift systems is expanded to explore a wider range of options for improving their efficiency. The refined conventional high-lift CRM (HL-CRM) concept features leading edge slats and slotted trailing edge flaps with Fowler motion. For the current AFC-enhanced high lift system trade study, the refined conventional high-lift system is simplified by substituting simply-hinged trailing edge flaps for the slotted single-element flaps with Fowler motion. The high-lift performance of these two high-lift CRM variants is established using Computational Fluid Dynamics (CFD) solutions to the Reynolds-Averaged Navier-Stokes (RANS) equations. These CFD assessments identify the high-lift performance that needs to be recovered through AFC to have the CRM variant with the lighter and mechanically simpler high-lift system match the performance of the conventional high-lift system. In parallel to the conventional high-lift concept development, parametric studies using CFD guided the development of an effective and efficient AFC-enabled simplified high-lift system. This included parametric trailing edge flap geometry studies addressing the effects of flap chord length and flap deflection. As for the AFC implementation, scaling effects (i.e., wind-tunnel versus full-scale flight conditions) are addressed, as are AFC architecture aspects such as AFC unit placement, number AFC units, operating pressures, mass flow rates, and steady versus unsteady AFC applications. These efforts led to the development of a novel traversing AFC actuation concept which is efficient in that it reduces the AFC mass flow requirements by as much as an order of magnitude compared to previous AFC technologies, and it is predicted to be effective in driving the aerodynamic performance of a mechanical simplified high-lift system close to that of the reference conventional high-lift system. Conceptual system integration studies were conducted for the AFC-enhanced high-lift concept applied to a NASA Environmentally Responsible Aircraft (ERA) reference configuration, the so-called ERA-0003 concept. The results from these design integration assessments identify overall system performance improvement opportunities over conventional high-lift systems that suggest the viability of further technology maturation efforts for AFC-enabled high lift flap systems. To that end, technical challenges are identified associated with the application of AFC-enabled high-lift systems to modern transonic commercial transports for future technology maturation efforts

    Effect of Mycophenolate Mofetil on Plasma Bioelements in Renal Transplant Recipients

    Get PDF
    The proper concentrations of plasma bioelements may favorably reduce the incidence of metabolic disorders, which often occur during immunosuppressive therapy. Mycophenolate mofetil (MMF) is currently one of the most frequently administered immunosuppressive agents; however, MMF treatment is often related to gastrointestinal side effects. The aim of this study was thus to verify whether the MMF treatment itself, or its metabolite pharmacokinetics, has an effect on the concentrations of plasma bioelements. To determine this, the effect of MMF on the levels of both major (sodium [Na], potassium [K], calcium [Ca], magnesium [Mg]), and trace (iron [Fe], zinc [Zn], copper [Cu]) plasma bioelements in 61 renal transplant recipients was assessed in comparison to a control group (n = 45). The pharmacokinetic parameters of mycophenolic acid were determined by the high-performance liquid chromatography method. All patients filled out a 24-h diet history questionnaire. The results showed high plasma concentrations of Fe and low plasma concentrations of Mg and Zn as compared with diagnostic norms. The patients treated with MMF had significantly lower plasma Na (P < 0.001) and significantly higher plasma Zn (P = 0.030) and Cu concentrations (P < 0.001). In conclusion, MMF treatment was found to affect plasma Fe, Zn, and Cu levels by increasing their concentrations while decreasing the plasma Na concentration. Mg and Zn deficiencies, as well as excessive Fe levels, are frequently observed irrespective of the immunosuppressive regimen applied, which suggests that monitoring of these bioelements may be favorable
    corecore