483 research outputs found

    Direct comparison of the performance of CZT detectors contacted with various metals

    Full text link
    Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over the broad energy range from several keV into the MeV energy range. In this paper we present the results of a systematic study of the performance of CZT detectors manufacturered by Orbotech (before IMARAD) depending on surface preparation, contact materials and contact deposition. The standard Orbotech detectors have the dimension of 2.0 x 2.0 x 0.5 cm. They have a pixellated In anode with 8 x 8 pixels and a monolithic In cathode. Using the same CZT substrates several times, we have made a direct comparison of the performance of different contact materials by replacing the cathode and/or the anode contacts with several high-workfunction metals. We present the performance of the detectors and conclude with an overview over our ongoing detector optimization.Comment: 8 pages, 5 figures, to appear in the proceedings of the conference 5922, "Hard X-Ray and Gamma-Ray Detector Physics VII" on the "Optics & Photonics 2005" SPIE Symposium, July 31- August 4, 2005, San Diego, C

    Evaluation of Bovine Embryo Biopsy Techniques according to Their Ability to Preserve Embryo Viability

    Get PDF
    The purpose of this research was to evaluate three embryo biopsy techniques used for preimplantation genetic diagnosis (PGD) in cattle and to recommend the least invasive one for current use, especially when PGD is followed by embryo cryopreservation. Three hundred bovine embryos were biopsied by either one of the needle, aspiration or microblade method, and then checked for viability by freezing/thawing and transplantation to recipient cows. The number of pregnancies obtained after the transfer of biopsied frozen/thawed embryos was assessed 30 days later using ultrasounds. The results were significantly different between the three biopsy methods: the pregnancy rate was of 57% in cows that received embryos biopsied by needle, 43% in cows that received embryos biopsied by aspiration, and 31% in cows that received embryos biopsied by microblade. Choosing an adequate biopsy method is therefore of great importance in embryos that will undergo subsequent cryopreservation, as it significantly influences their viability after thawing

    Thick CZT Detectors for Space-Borne X-ray Astronomy

    Full text link
    Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to 600 keV. In this paper, we briefly review the historical development of detectors used in X-ray astronomy. Subsequently, we present an evaluation of CZT detectors from the company Imarad. The standard 2x2x0.5 cm detectors, contacted with 8x8 In pixels and an In cathode, exhibit FWHM energy resolutions of 7 keV at 59 keV, and 10 keV at 662 keV. A direct measurement of the 662 keV photopeak efficiency gives 67%. We have started a detailed study of the performance of Imarad detectors depending on surface preparation, contact materials, contact deposition, post-deposition detector annealing, and detector passivation techniques. We present first results from contacting detectors with Cr, Ag, Au, and Pt.Comment: Invited Contribution to the 49th International Symposium on Optical Science and Technology (SPIE), August 2004, Denver, CO, SPIE, 49, 5540, 13.01. (2004

    Detailed Studies of Pixelated CZT Detectors Grown with the Modified Horizontal Bridgman Method

    Full text link
    The detector material Cadmium Zinc Telluride (CZT), known for its high resolution over a broad energy range, is produced mainly by two methods: the Modified High-Pressure Bridgman (MHB) and the High-Pressure Bridgman (HPB) process. This study is based on MHB CZT substrates from the company Orbotech Medical Solutions Ltd. with a detector size of 2.0x2.0x0.5 cm^3, 8x8 pixels and a pitch of 2.46 mm. Former studies have emphasized only on the cathode material showing that high-work-function improve the energy resolution at lower energies. Therfore, we studied the influence of the anode material while keeping the cathode material constant. We used four different materials: Indium, Titanium, Chromium and Gold with work-functions between 4.1 eV and 5.1 eV. The low work-function materials Indium and Titanium achieved the best performance with energy resolutions: 2.0 keV (at 59 keV) and 1.9 keV (at 122 keV) for Titanium; 2.1 keV (at 59 keV) and 2.9 keV (at 122 keV) for Indium. These detectors are very competitive compared with the more expensive ones based on HPB material if one takes the large pixel pitch of 2.46 mm into account. We present a detailed comparison of our detector response with 3-D simulations, from which we determined the mobility-lifetime-products for electrons and holes. Finally, we evaluated the temperature dependency of the detector performance and mobility-lifetime-products, which is important for many applications. With decreasing temperature down to -30C the breakdown voltage increases and the electron mobility-lifetime-product decreases by about 30% over a range from 20C to -30C. This causes the energy resolution to deteriorate, but the concomitantly increasing breakdown voltage makes it possible to increase the applied bias voltage and restore the full performance.Comment: Accepted for publication in Astroparticle Physics, 25 pages, 13 figure

    Research on environmental impact assessment of flame oxyacetylene welding processes

    Get PDF
    This paper presents the factors that may cause pollution of the work environment when working with the oxyacetylene flame welding process. Experiments were performed using an oven that allows the analysis of all gases resulted in the welding process, but also enables their monitoring using a video camera, and the resulting film was processed in that the frames for each second of experimentation were extracted. The materials used in the experiments were S235JR steel as the base material, and as filler materials, E70S. In order to assess the impact on the work environment of this welding process, the pollution coefficient CP was defined based on the equation of the material balance
    • 

    corecore