426 research outputs found
The Application of Half-Life in Clinical Decision Making: Comparison of the Pharmacokinetics of Extended-Release Topiramate (USL255) and Immediate-Release Topiramate
Objective: For extended-release drugs with multi-compartment kinetics, such as topiramate, effective half-life (t1/2eff) may be a more clinically relevant parameter than elimination half-life (t1/2z). Using topiramate as a real-life example, the objective was to compare these half-life values for immediate- and extended-release topiramate (TPM-IR and USL255, respectively) to understand how drug pharmacokinetics may impact drug dosing recommendations.
Methods: The t1/2z and t1/2eff for USL255 and TPM-IR were compared using data from a phase I study (N = 36) of 200 mg USL255 administered once daily (QD) or TPM-IR twice daily (BID); effect of sampling duration on t1/2z was investigated. To further explore the relationship between half-life and dosing, steady-state PK was simulated for USL255 and TPM-IR.
Results: As previously reported, mean t1/2z was similar between USL255 (80.2 h) and TPM-IR (82.8 h); TPM-IR t1/2z was âŒ4 times longer than reported in the Topamax label (21 h). In contrast, USL255 displayed a 1.5 fold longer t1/2eff (55.7 vs 37.1 h for TPM-IR). When t1/2z was calculated from 48 to 336 h, values ranged from 28.8 to 82.8 h. Simulated steady-state PK profiles of USL255 QD exhibited reduced plasma fluctuations during a dosing interval vs TPM-IR QD or BID.
Significance: As expected for the same moiety, t1/2z of USL255 and TPM-IR were similar; however, the longer t1/2eff for USL255 better approximates differences in recommend dosing (QD USL255 vs BID TPM-IR). Further, sampling duration impacted t1/2z, diminishing its predictive value for determining dose regimens; sampling-time differences may also explain t1/2z discrepancy between TPM-IR here versus Topamax label. As expected, steady-state simulations confirm that although TPM-IR has a long t1/2z, taking TPM-IR QD would lead to large plasma fluctuations. These data demonstrate that t1/2z may be less clinically meaningful than t1/2eff, and using t1/2z for some drugs may lead to erroneous conclusions regarding dosing regimens
Multipole Amplitudes of Pion Photoproduction on Nucleons up to 2GeV within Dispersion Relations and Unitary Isobar Model
Two approaches for analysis of pion photo- and electroproduction on nucleons
in the resonance energy region are checked at using the results of
GWU(VPI) partial-wave analysis of photoproduction data. The approaches are
based on dispersion relations and unitary isobar model. Within dispersion
relations good description of photoproduction multipoles is obtained up to
. Within unitary isobar model, modified with increasing energy by
incorporation of Regge poles, and with unified Breit-Wigner parametrization of
resonance contributions, good description of photoproduction multipoles is
obtained up to .Comment: 23 pages, LaTe
Measurement of the Alpha Asymmetry Parameter for the Omega- to Lambda K- Decay
We have measured the alpha parameter of the Omega- to Lambda K- decay using
data collected with the HyperCP spectrometer during the 1997 fixed-target run
at Fermilab. Analyzing a sample of 0.96 million Omega- to Lambda K^-, Lambda to
p pi- decays, we obtain alpha_Omega*alpha_Lambda =
[1.33+/-0.33(stat)+/-0.52(syst)] x 10^{-2}. With the accepted value of
alpha_Lambda, alpha_Omega is found to be [2.07+/-0.51(stat)+/-0.81(syst)] x
10^{-2}.Comment: 5 pages, 4 figures, to be appeared as a Rapid Communication in Phys.
Rev.
Evidence for the Decay Sigma+ -> p mu+ mu-
We report the first evidence for the decay Sigma+ -> p mu+ mu- from data
taken by the HyperCP experiment(E871) at Fermilab. Based on three observed
events, the branching ratio is B(Sigma+ -> p,mu+,mu-) = [8.6 +6.6,-5.4(stat)
+/-5.5(syst)] x 10**-8. The narrow range of dimuon masses may indicate that the
decay proceeds via a neutral intermediate state, Sigma+ -> p P0, P0 -> mu+ mu-,
with a P0 mass of 214.3 +/- 0.5 MeV/c**2 and branching ratio B(Sigma+ -> p P0;
P0 -> mu+ mu-) = [3.1 +2.4,-1.(stat) +/-1.5(syst)] x 10**-8.Comment: As published in PR
Search for the Lepton-Number-Violating Decay
A sensitive search for the lepton-number-violating decay has been performed using a sample of hyperons
produced in 800 GeV/ -Cu collisions. We obtain at 90% confidence, improving on the best
previous limit by four orders of magnitude.Comment: 9 pages, 5 figures, to be published in Phys. Rev. Let
Observation of Parity Violation in the Omega-minus -> Lambda + K-minus Decay
The alpha decay parameter in the process Omega-minus -> Lambda + K-minus has
been measured from a sample of 4.50 million unpolarized Omega-minus decays
recorded by the HyperCP (E871) experiment at Fermilab and found to be [1.78 +/-
0.19(stat) +/- 0.16(syst)]{\times}10^{-2}. This is the first unambiguous
evidence for a nonzero alpha decay parameter, and hence parity violation, in
the Omega-minus -> Lambda + K-minus decay.Comment: 10 pages, 7 figure
Search for flavor-changing neutral currents and lepton-family-number violation in two-body D0 decays
Results of a search for the three neutral charm decays, D0 -> mu e, D0 -> mu
mu, and D0 -> e e, are presented. This study was based on data collected in
Experiment 789 at the Fermi National Accelerator Laboratory using 800 GeV/c
proton-Au and proton-Be interactions. No evidence is found for any of the
decays. Upper limits on the branching ratios, at the 90% confidence level, are
obtained.Comment: 28 pages, 18 figures. Submitted to Physical Review
HyperCP: A high-rate spectrometer for the study of charged hyperon and kaon decays
The HyperCP experiment (Fermilab E871) was designed to search for rare
phenomena in the decays of charged strange particles, in particular CP
violation in and hyperon decays with a sensitivity of
. Intense charged secondary beams were produced by 800 GeV/c protons
and momentum-selected by a magnetic channel. Decay products were detected in a
large-acceptance, high-rate magnetic spectrometer using multiwire proportional
chambers, trigger hodoscopes, a hadronic calorimeter, and a muon-detection
system. Nearly identical acceptances and efficiencies for hyperons and
antihyperons decaying within an evacuated volume were achieved by reversing the
polarities of the channel and spectrometer magnets. A high-rate
data-acquisition system enabled 231 billion events to be recorded in twelve
months of data-taking.Comment: 107 pages, 45 Postscript figures, 14 tables, Elsevier LaTeX,
submitted to Nucl. Instrum. Meth.
- âŠ