8,562 research outputs found

    Large Transverse Momentum Jet Production and DIS Distributions of the Proton

    Get PDF
    We have calculated the single jet inclusive cross section as measured at Fermilab in next-to-leading order QCD using recent parton distributions of the CTEQ collaboration. We studied the scheme dependence of the jet cross section by employing the \overline{\mbox{MS}} and DIS factorization schemes consistently. For ET>200E_T > 200 GeV, we find that the cross section in the DIS scheme is larger than in the \overline{\mbox{MS}} scheme yielding a satisfactory description of the CDF data over the whole ETE_T range in the DIS scheme.Comment: 7 pages, latex, 2 figures include

    Virtual edge illumination and one dimensional beam tracking for absorption, refraction, and scattering retrieval

    Get PDF
    We propose two different approaches to retrieve x-ray absorption, refraction, and scattering signals using a one dimensional scan and a high resolution detector. The first method can be easily implemented in existing procedures developed for edge illumination to retrieve absorption and refraction signals, giving comparable image quality while reducing exposure time and delivered dose. The second method tracks the variations of the beam intensity profile on the detector through a multi-Gaussian interpolation, allowing the additional retrieval of the scattering signal

    Laboratory implementation of edge illumination X-ray phase-contrast imaging with energy-resolved detectors

    Get PDF
    Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has potential for applications in different fields of research, including materials science, non-destructive industrial testing, small-animal imaging, and medical imaging. One of its main advantages is the compatibility with laboratory equipment, in particular with conventional non-microfocal sources, which makes its exploitation in normal research laboratories possible. In this work, we demonstrate that the signal in laboratory implementations of EI can be correctly described with the use of the simplified geometrical optics. Besides enabling the derivation of simple expressions for the sensitivity and spatial resolution of a given EI setup, this model also highlights the EI’s achromaticity. With the aim of improving image quality, as well as to take advantage of the fact that all energies in the spectrum contribute to the image contrast, we carried out EI acquisitions using a photon-counting energy-resolved detector. The obtained results demonstrate that this approach has great potential for future laboratory implementations of EI. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Edge illumination X-ray phase tomography of multi-material samples using a single-image phase retrieval algorithm

    Get PDF
    In this paper we present a single-image phase retrieval algorithm for multi-material samples, developed for the edge illumination (EI) X-ray phase contrast imaging method. The theoretical derivation is provided, along with any assumptions made. The algorithm is evaluated quantitatively using both simulated and experimental results from a computed tomography (CT) scan using the EI laboratory implementation. Qualitative CT results are provided for a biological sample containing both bone and soft-tissue. Using a single EI image per projection and knowledge of the complex refractive index, the algorithm can accurately retrieve the interface between a given pair of materials. A composite CT slice can be created by splicing together multiple CT reconstructions, each retrieved for a different pair of materials

    Optimization of sensitivity, dose and spatial resolution in edge illumination X-ray phase-contrast imaging

    Get PDF
    Edge illumination (EI) X-ray phase-contrast imaging has great potential for applications in a wide range of research, industrial and clinical fields. The optimization of the EI experimental setup for a given application is therefore essential, in order to take full advantage of the capabilities of the technique. In this work, we analyze the dependence of the angular sensitivity, spatial resolution and dose delivered to the sample upon the various experimental parameters, and describe possible strategies to optimize them. The obtained results will be important for the design of future EI experimental setups, in particular enabling their tailoring to specific applications

    Comparing signal intensity and refraction sensitivity of double and single mask edge illumination lab-based x-ray phase contrast imaging set-ups

    Get PDF
    Double mask edge illumination (DM-EI) set-ups can detect differential phase and attenuation information from a sample. However, analytical separation of the two signals often requires acquiring two frames with inverted differential phase contrast signals. Typically, between these two acquisitions, the first mask is moved to create a different illumination condition. This can lead to potential errors which adversely affect the data collected. In this paper, we implement a single mask EI laboratory set-up that allows for a single shot retrieval of the differential phase and attenuation images, without the need for a high resolution detector or high magnification. As well as simplifying mask alignment, the advantages of the proposed set-up can be exploited in one of two ways: either the total acquisition time can be halved with respect to the DM-EI set-up or, for the same acquisition time, twice the statistics can be collected. In this latter configuration, the signal-to-noise ratio and contrast in the mixed intensity images, and the angular sensitivity of the two set-ups were compared. We also show that the angular sensitivity of the single mask set-up can be well approximated from its illumination curve, which has been modelled as a convolution between the source spatial distribution at the detector plane, the pre-sample mask and the detector point spread function (PSF). A polychromatic wave optics simulation was developed on these bases and benchmarked against experimental data. It can also be used to predict the angular sensitivity and contrast of any set-up as a function of detector PSF

    Debajyoti Choudhury

    Full text link
    Gluon fusion into a very heavy neutrino pair by Higgs exchange is shown to lead to substantial production cross sections at pppp supercolliders even without any extra generation of quarks. Rates are calculated for scalar as well as pseudoscalar Higgs. The angular correlation between dileptons emerging from the decays of the neutrinos shows distinctive features for Dirac and Majorana neutrinos as well as for scalar and pseudoscalar Higgs

    Anomalous prompt photon production in hadronic collisions at low-xTx_T

    Full text link
    We investigate the discrepancy that exists at low-xT=2pT/sx_T=2p_T/\sqrt{s} between the next--to--leading order QCD calculations of prompt photon production and the measured cross section. The central values of the measured cross section are of order 100\% larger than QCD predictions in this region. It has been suggested that the bremsstrahlung contribution may account for this discrepancy. The quark fragmentation function Dγ/q(z)D_{\gamma/q}(z) has not been measured and an exactly known asymptotic form is normally used in calculations. We examine the effect of much larger fragmentation functions on the QCD predictions. After illustrating the effect of the large fragmentation functions in some detail for recent CDF data at s\sqrt{s}=1.8~TeV, we perform a χ2\chi^2 fit to 8 prompt photon data sets ranging in CMS energy from 24~GeV to 1.8~TeV. While a large fragmentation function normalization may prove to play an important role in resolving the discrepancy, the present theoretical and experimental uncertainties prevent any definite normalization value from being determined.Comment: 14 pages, LBL-33122 and UCB-PTH-92/38. 13 figures available by email, specify postscript or topdrawe

    Improved sensitivity at synchrotrons using edge illumination X-ray phase-contrast imaging

    Get PDF
    The application of the X-ray phase-contrast ‘edge illumination’ principle to the highly coherent beams available at synchrotron radiation facilities is presented here. We show that, in this configuration, the technique allows achieving unprecedented angular sensitivity, of the order of few nanoradians. The results are obtained at beamlines of two different synchrotron radiation facilities, using various experimental conditions. In particular, different detectors and X-ray energies (12 keV and 85 keV) were employed, proving the flexibility of the method and the broad range of conditions over which it can be applied. Furthermore, the quantitative separation of absorption and refraction information, and the application of the edge illumination principle in combination with computed tomography, are also demonstrated. Thanks to its extremely high phase sensitivity and its flexible applicability, this technique will both improve the image quality achievable with X-ray phase contrast imaging and allow tackling areas of application which remain unexplored until now
    corecore