152,820 research outputs found

    Spray coating apparatus having a rotatable workpiece holder

    Get PDF
    A spray coating apparatus is provided for rotating a workpiece relative to a spray station to obtain a uniform coating of the workpiece. In a typical example, the workpiece comprises a ceramic tile which is to be coated with a ceramic coating and the tile is to be used as a reusable component of the thermal protection system for a space shuttle. The apparatus for rotating the workpiece includes a base support having a first rotatable stage for rotation in the horizontal plane and a second rotatable stage for rotation in a second plane inclined at an angle, such as 45 degrees, to the horizontal plane and the workpiece is supported on this second stage. Thus the workpiece is rotatable in both of two planes of rotation

    Effect of oxygen concentration on the structural and magnetic properties of LaRh1/2Mn1/2O3 thin films

    Full text link
    Epitaxial LaRh1/2Mn1/2O3 thin films have been grown on (001)-oriented LaAlO3 and SrTiO3 substrates using pulsed laser deposition. The optimized thin film samples are semiconducting and ferromagnetic with a Curie temperature close to 100 K, a coercive field of 1200 Oe, and a saturation magnetization of 1.7muB per formula unit. The surface texture, structural, electrical, and magnetic properties of the LaRh1/2Mn1/2O3 films was examined as a function of the oxygen concentration during deposition. While an elevated oxygen concentration yields thin films with optimal magnetic properties, slightly lower oxygen concentrations result in films with improved texture and crystallinity

    Mid-infrared Imaging of a Circumstellar Disk Around HR 4796: Mapping the Debris of Planetary Formation

    Get PDF
    We report the discovery of a circumstellar disk around the young A0 star, HR 4796, in thermal infrared imaging carried out at the W.M. Keck Observatory. By fitting a model of the emission from a flat dusty disk to an image at lambda=20.8 microns, we derive a disk inclination, i = 72 +6/-9 deg from face on, with the long axis of emission at PA 28 +/-6 deg. The intensity of emission does not decrease with radius as expected for circumstellar disks but increases outward from the star, peaking near both ends of the elongated structure. We simulate this appearance by varying the inner radius in our model and find an inner hole in the disk with radius R_in = 55+/-15 AU. This value corresponds to the radial distance of our own Kuiper belt and may suggest a source of dust in the collision of cometesimals. By contrast with the appearance at 20.8 microns, excess emission at lambda = 12.5 microns is faint and concentrated at the stellar position. Similar emission is also detected at 20.8 microns in residual subtraction of the best-fit model from the image. The intensity and ratio of flux densities at the two wavelengths could be accounted for by a tenuous dust component that is confined within a few AU of the star with mean temperature of a few hundred degrees K, similar to that of zodiacal dust in our own solar system. The morphology of dust emission from HR 4796 (age 10 Myr) suggests that its disk is in a transitional planet-forming stage, between that of massive gaseous proto-stellar disks and more tenuous debris disks such as the one detected around Vega.Comment: 9 pages, 4 figures as LaTex manuscript and postscript files in gzipped tar file. Accepted for publication in Astrophysical Journal Letters. http://upenn5.hep.upenn.edu/~davidk/hr4796.htm

    DASI Three-Year Cosmic Microwave Background Polarization Results

    Full text link
    We present the analysis of the complete 3-year data set obtained with the Degree Angular Scale Interferometer (DASI) polarization experiment, operating from the Amundsen-Scott South Pole research station. Additional data obtained at the end of the 2002 Austral winter and throughout the 2003 season were added to the data from which the first detection of polarization of the cosmic microwave background radiation was reported. The analysis of the combined data supports, with increased statistical power, all of the conclusions drawn from the initial data set. In particular, the detection of E-mode polarization is increased to 6.3 sigma confidence level, TE cross-polarization is detected at 2.9 sigma, and B-mode polarization is consistent with zero, with an upper limit well below the level of the detected E-mode polarization. The results are in excellent agreement with the predictions of the cosmological model that has emerged from CMB temperature measurements. The analysis also demonstrates that contamination of the data by known sources of foreground emission is insignificant.Comment: 13 pages Latex, 10 figures, submitted to Ap

    Automated weld torch guidance control system

    Get PDF
    A device for automatically controlling the movement of a welding torch while welding an elongated joint is described. A charge injection television camera is carried on a movable support. The camera includes a matrix of individual light sensing video elements which generate voltages responsive to light reflected off of the joint and surrounding areas of the work piece. The voltages produced by the pixels are converted to digital words which are fed to a microprocessor for generating an error signal. This error signal is fed to a digital motor which is used to drive a movable support upon which the television camera is carried

    Analytical and experimental investigation of flow fields of annular jets with and without swirling flow

    Get PDF
    Analytical and experimental studies were performed to define the flowfield of annular jets, with and, without swirling flow. The analytical model treated configurations with variations of flow angularities, radius ratio, and swirl distributions. Swirl distributions characteristic of stator vanes and rotor blade rows, where the total pressure and swirl distributions are related were incorporated in the mathematical model. The experimental studies included tests of eleven nozzle models, both with and, without swirling exhaust flow. Flowfield surveys were obtained and used for comparison with the analytical model. This comparison of experimental and analytical studies served as the basis for evaluation of several empirical constants as required for application of the analysis to the general flow configuration. The analytical model developed during these studies is applicable to the evaluation of the flowfield and overall performance of the exhaust of statorless lift fan systems that contain various levels of exhaust swirl

    Exposure of a tendon extracellular matrix to synovial fluid triggers endogenous and engrafted cell death: A mechanism for failed healing of intrathecal tendon injuries

    Get PDF
    Aim: The purpose of this study was to investigate the effect of normal synovial fluid (SF) on exposed endogenous tendon-derived cells (TDC) and engrafted mesenchymal stem cells (MSCs) within the tendon extracellular matrix. Methods: Explants from equine superficial digital flexor (extra-synovial) and deep digital flexor tendons (DDFT) from the compressed, intra-synovial and the tensile, extra-synovial regions were cultured in allogeneic or autologous SF-media. Human hamstring explants were cultured in allogeneic SF. Explant viability was assessed by staining. Proliferation of equine monolayer MSCs and TDCs in SF-media and co-culture with DDFT explants was determined by alamarblue®. Non-viable Native Tendon matrices (NNTs) were re-populated with MSCs or TDCs and cultured in SF-media. Immunohistochemical staining of tendon sections for the apoptotic proteins caspase-3, -8 and -9 was performed. Results: Contact with autologous or allogeneic SF resulted in rapid death of resident tenocytes in equine and human tendon. SF did not affect the viability of equine epitenon cells, or of MSCs and TDCs in monolayer or indirect explant co-culture. MSCs and TDCs, engrafted into NNTs, died when cultured in SF. Caspase-3, -8 and -9 expression was greatest in SDFT explants exposed to allogeneic SF. Conclusions: The efficacy of cells administered intra-synovially for tendon lesion repair is likely to be limited, since once incorporated into the matrix, cells become vulnerable to the adverse effects of SF. These observations could account for the poor success rate of intra-synovial tendon healing following damage to the epitenon and contact with SF, common with most soft tissue intra-synovial pathologies
    corecore