77 research outputs found

    Septic hip abscess due to Fusobacterium nucleatum and Actinomyces turicensis in an immunocompetent SARS-CoV-2 positive patient

    Get PDF
    A 42-year-old man was referred to the Department of Orthopedic Surgery with pain over his right greater trochanter and signs of systemic infection. CT showed an enhanced mass in his gluteus maximus as well as gas in the biceps femoris over the underlying hip joint. Tissue biopsy yielded Fusobacterium nucleatum and Actinomyces turicensis. The patient was successfully treated for 6 weeks with amoxicillin/clavulanic acid 875mg/125mg and metronidazole 500mg

    Therapy reduction in patients with Down syndrome and myeloid leukemia: the international ML-DS 2006 trial

    Get PDF
    Children with myeloid leukemia associated with Down syndrome (ML-DS) have superior outcome compared with non-DS patients, but suffer from higher constitutional cytotoxic drug susceptibility. We analyzed the outcome of 170 pediatric patients with ML-DS enrolled in the prospective, multicenter, open-label, nonrandomized ML-DS 2006 trial by Nordic Society for Pediatric Hematology and Oncology (NOPHO), Dutch Childhood Oncology Group (DCOG), and Acute Myeloid Leukemia–Berlin-Frankfurt-Münster (AML-BFM) study group. Compared with the historical control arm (reduced-intensity protocol for ML-DS patients from the AML-BFM 98 trial), treatment intensity was reduced by lowering the cumulative dose of etoposide (950 to 450 mg/m2) and intrathecal central nervous system prophylaxis while omitting maintenance therapy. Still, 5-year overall survival (89% 6 3% vs 90% 6 4%; Plog-rank 5 .64), event-free survival (EFS; 87% 6 3% vs 89% 6 4%; Plog-rank 5 .71), and cumulative incidence of relapse/ nonresponse (CIR/NR; 6% 6 3% vs 6% 6 2%; PGray 5 .03) did not significantly differ between the ML-DS 2006 trial and the historical control arm. Poor early treatment response (5-year EFS, 58% 6 16% vs 88% 6 3%; Plog rank 5 .0008) and gain of chromosome 8 (CIR/NR, 16% 6 7% vs 3% 6 2%, PGray 5 .02; 5-year EFS, 73% 6 8% vs 91% 6 4%, Plog rank 5 .018) were identified as independent prognostic factors predicting a worse EFS. Five of 7 relapsed patients (71%) with cytogenetic data had trisomy 8. Our study reveals prognostic markers for children with ML-DS and illustrates that reducing therapy did not impair excellent outcome. The trial was registered at EudraCT as #2007-006219-2. (Blood. 2017;129(25): 3314-3321

    Digital chest radiography: an update on modern technology, dose containment and control of image quality

    Get PDF
    The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems

    Erhöhung der Liefertreue: Werksübergreifende Abwicklung von Kundenaufträgen in der Serien- und Einzelfertigung

    No full text
    Steigerung der Wettbewerbsfähigkeit durch klare Definition der Unternehmensstrategie und Top Down Ableitung von Teilzielen sowie deren Leistungskennzahlen (PPM Process Performance Measures) für Unternehmensbereiche und Abteilungen zur Bottom Up Messung der Umsetzungserfolge. Die Projektorganisation wird nach den Unternehmenszielen und den entsprechenden Teilzielen strukturiert und durch die Methode Hoshin das Projektcontrolling übernommen. Zur Umsetzung der Wettbewerbsstrategie wurde im Rahmen der Projektarbeit unter anderen die Methodik Wertstromdesign zur Durchlaufzeitreduktion und Produktivitätssteigerung am Engpass eingesetzt

    Abwägen von Dosisbedarf und Bildqualität in der digitalen Radiographie

    No full text
    Projection radiography is in an advanced stage of progressive transition from conventional screen-film imaging to digital image acquisition modalities. The radiographic technique, including examination parameters such as tube voltage, tube current and filtration has frequently been adopted from screen-film technology. Digital systems, however, are characterized by their flexibility as the dose can be reduced at the expense of image quality and vice versa. The imaging parameters need to be individually optimized according to the best performance of a system. The traditional means of dose adjustment, such as positioning and collimation, are as valid for digital techniques as they were for conventional techniques. Digital techniques increasingly offer options for dose reduction. At the same time there is a risk to accidentally substantially increase patient dose due to the lack of visual control. Therefore, the implementation of dose indicators and dose monitoring is mandatory for digital radiography. The use of image quality classes according to the dose requirements of given clinical indications are a further step towards modern radiation protectio

    DR and CR: Recent advances in technology.

    No full text
    Item does not contain fulltextAfter some initial reluctance, nowadays transition from conventional analogue-to-digital radiographic technique is realized in the vast majority of institutions. The eventual triumph of digital over conventional technique is related to its undoubted advantages with respect to image quality and improved image handling in the context of a picture archiving and communication system. CR represents the older system, which matured over decades and experienced some important recent improvements with respect to dose efficiency and work-flow efficiency that strengthened its position. It represents a very versatile, economically attractive system that is equally suited for integrated systems as well as for cassette-based imaging at the bedside. DR systems offer superb image quality and realistic options for dose reduction based on their high dose efficiency. While for a long time only integrated systems were on the market suited for a large patient throughput, also mobile DR systems became recently available. While for the next years, it is likely that DR and CR systems will coexist, the long term perspective of CR will depend on further innovations with respect to dose efficiency and signal-to-noise characteristics while for DR economical aspects and broader availability of mobile systems will play a role

    [Detection of lung nodules. New opportunities in chest radiography]

    No full text
    Item does not contain fulltextChest radiography still represents the most commonly performed X-ray examination because it is readily available, requires low radiation doses and is relatively inexpensive. However, as previously published, many initially undetected lung nodules are retrospectively visible in chest radiographs.The great improvements in detector technology with the increasing dose efficiency and improved contrast resolution provide a better image quality and reduced dose needs.The dual energy acquisition technique and advanced image processing methods (e.g. digital bone subtraction and temporal subtraction) reduce the anatomical background noise by reduction of overlapping structures in chest radiography. Computer-aided detection (CAD) schemes increase the awareness of radiologists for suspicious areas.The advanced image processing methods show clear improvements for the detection of pulmonary lung nodules in chest radiography and strengthen the role of this method in comparison to 3D acquisition techniques, such as computed tomography (CT).Many of these methods will probably be integrated into standard clinical treatment in the near future. Digital software solutions offer advantages as they can be easily incorporated into radiology departments and are often more affordable as compared to hardware solutions
    corecore