166 research outputs found
Long-lived refractive index changes induced by femtosecond ionization in gas-filled single-ring photonic crystal fibers
We investigate refractive index changes caused by femtosecond photoionization
in a gas-filled hollow-core photonic crystal fiber. Using spatially-resolved
interferometric side-probing, we find that these changes live for tens of
microseconds after the photoionization event - eight orders of magnitude longer
than the pulse duration. Oscillations in the megahertz frequency range are
simultaneously observed, caused by mechanical vibrations of the thin-walled
capillaries surrounding the hollow core. These two non-local effects can affect
the propagation of a second pulse that arrives within their lifetime, which
works out to repetition rates of tens of kilohertz. Filling the fiber with an
atomically lighter gas significantly reduces ionization, lessening the strength
of the refractive index changes. The results will be important for
understanding the dynamics of gas-based fiber systems operating at high
intensities and high repetition rates, when temporally non-local interactions
between successive laser pulses become relevant.Comment: 5 pages with four figures and one tabl
Comics and Composition, Comics as Composition: Navigating Production and Consumption
Composition has a vested interest in exploring how comics studies can inform our teaching of writing, multimodal literacies, and visual rhetoric. Composition and rhetoric has already demonstrated a growing interest in comics (including graphic literatures, graphic novels, graphic narratives, digital storytelling) as complex sites of literacy and as spaces to theorize and practice multimodal composing. Comics also provide opportunities to explore the rhetorical choices and transactions that must be negotiated between composers and readers. However, despite composition scholars’ interest in multiliteracies, multimodal composing, and visual rhetoric, the interdependent and fluid connections between images and words remain largely disengaged. For example, in Embodied Literacies, Kristie Fleckenstein coined the term “imageword” to disrupt the binary that often exists between word and image and to revitalize the use of images in the composing process
Case report of a cervical myelomalacia caused by a thoracolumbar intradural disc herniation leading to intracranial hypotension
A 50-year-old patient was admitted with symptoms of intracranial hypotension. MRI revealed a cervical myelomalacia caused by engorged epidural veins leading to a stenosis of the spinal canal. This condition is rarely described in patients with hydrocephalus and ventricular shunts suffering from chronic overdrainage. However, the reason in this patient was a CSF leak caused by an intradural disc herniation at T12/L1. After surgery, symptoms resolved and the cervical myelomalacia and the swollen epidural veins disappeared on postoperative MRI. In patients with engorged cervical epidural veins without a ventricular shunt, a CSF leak has to be considered
In vivo temporal and spatial profile of leukocyte adhesion and migration after experimental traumatic brain injury in mice
Background: Leukocytes are believed to be involved in delayed cell death following traumatic brain injury (TBI). However, data demonstrating that blood-borne inflammatory cells are present in the injured brain prior to the onset of secondary brain damage have been inconclusive. We therefore investigated both the interaction between leukocytes and the cerebrovascular endothelium using in vivo imaging and the accumulation of leukocytes in the penumbra following experimentally induced TBI. Methods: Experimental TBI was induced in C57/Bl6 mice (n = 42) using the controlled cortical impact (CCI) injury model, and leukocyte-endothelium interactions (LEI) were quantified using both intravital fluorescence microscopy (IVM) of superficial vessels and 2-photon microscopy of cortical vessels for up to 14 h post-CCI. In a separate experimental group, leukocyte accumulation and secondary lesion expansion were analyzed in mice that were sacrificed 15 min, 2, 6, 12, 24, or 48 h after CCI (n = 48). Finally, leukocyte adhesion was blocked with anti-CD18 antibodies, and the effects on LEI and secondary lesion expansion were determined 16 (n = 12) and 24 h (n = 21), respectively, following TBI. Results: One hour after TBI leukocytes and leukocyte-platelet aggregates started to roll on the endothelium of pial venules, whereas no significant LEI were observed in pial arterioles or in sham-operated mice. With a delay of >4 h, leukocytes and aggregates did also firmly adhere to the venular endothelium. In deep cortical vessels (250 mu m) LEIs were much less pronounced. Transmigration of leukocytes into the brain parenchyma only became significant after the tissue became necrotic. Treatment with anti-CD18 antibodies reduced adhesion by 65\%; however, this treatment had no effect on secondary lesion expansion. Conclusions: LEI occurred primarily in pial venules, whereas little or no LEI occurred in arterioles or deep cortical vessels. Inhibiting LEI did not affect secondary lesion expansion. Importantly, the majority of migrating leukocytes entered the injured brain parenchyma only after the tissue became necrotic. Our results therefore suggest that neither intravascular leukocyte adhesion nor the migration of leukocytes into cerebral tissue play a significant role in the development of secondary lesion expansion following TBI
Recommended from our members
Subcooled Boiling Near a Heated Wall
Experimental measurements of void fraction, bubble frequency, and velocity are obtained in subcooled R-134a flowing over a heated flat plate near an unheated wall and compared to analytical predictions. The measurements were obtained for a fixed system pressure and mass flow rate (P = 2.4 MPa and w = 106 kg/hr) at various inlet liquid temperatures. During the experiments, electrical power was applied at a constant rate to one side of the test section. The local void fraction data, acquired with a hot-film anemometer probe, showed the existence of a significant peak near the heated wall and a smaller secondary peak near the unheated wall for the larger inlet subcoolings. Local vapor velocity data, taken with the hot-film probe and a laser Doppler velocimeter, showed broad maxima near the centerline between the heated and unheated plates. Significant temperature gradients near the heated wall were observed for large inlet subcooling. Bubble size data, inferred from measurements of void fraction, bubble frequency and vapor velocity, when combined with the measured bubble chord length distributions illustrate the transition from pure three dimensional spherical to two-dimensional planar bubble flow, the latter being initiated when the bubbles fill the gap between the plates. These various two-phase flow measurements were used for development of a multidimensional, four-field calculational method; comparisons of the data to the calculations show reasonable agreement
Biological CO2-methanation: An approach to standardization
Power-to-Methane as one part of Power-to-Gas has been recognized globally as one of the key elements for the transition towards a sustainable energy system. While plants that produce methane catalytically have been in operation for a long time, biological methanation has just reached industrial pilot scale and near-term commercial application. The growing importance of the biological method is reflected by an increasing number of scientific articles describing novel approaches to improve this technology. However, these studies are diffcult to compare because they lack a coherent nomenclature. In this article, we present a comprehensive set of parameters allowing the characterization and comparison of various biological methanation processes. To identify relevant parameters needed for a proper description of this technology, we summarized existing literature and defined system boundaries for Power-to-Methane process steps. On this basis, we derive system parameters providing information on the methanation system, its performance, the biology and cost aspects. As a result, three different standards are provided as a blueprint matrix for use in academia and industry applicable to both, biological and catalytic methanation. Hence, this review attempts to set the standards for a comprehensive description of biological and chemical methanation processes
Ehrlich ascites tumor-bearing mice treated with aqueous ethanol plant extract from Euphorbia tirucalli showed signs of systemic toxicity
Purpose: To evaluate the antitumor effect of a latex extract from Euphorbia tirucalli Linn. (Euphorbiaceae) and its toxicity.Methods: Aqueous ethanol and petroleum ether extracts were obtained through maceration. .Maximum tolerated dose was determined in healthy mice. Antitumor activity was measured in Ehrlich ascites tumor-bearing mice treated with the extract through intraperitoneal injection (62.5, 125 or 250 mg/kg) every 48 h (four doses). Efficacy was assessed by weight gain, abdominal circumference, volume of ascitic fluid and packed tumor cells, tumor cell viability and survival. Toxicity indicators were serum glucose, triglycerides, total proteins, activity of alanine and aspartate aminotransferases and mass of heart, spleen, kidney and liver. A hemolysis assay was also performed.Results: Doses of 62.5 and 125 mg/kg caused no antitumor activity, while 250 mg/kg dose reduced weight gain (3-fold), abdominal circumference and volume of ascitic fluid (> 50 %) and packed cells (50 %), but lowered tumor cell viability (40 %). However, mice treated with the extract survived for a shorter time than control mice. Furthermore, the 250 mg/kg dose caused cardiac atrophy, splenomegaly and fasting hyperglycemia. The extract caused hemolysis, and the half-maximal effective concentration (EC50) was 1.6 (0.9 – 2.7) mg/mL.Conclusion: Euphorbia tirucalli extract inhibits Ehrlich ascites tumor in mice, but the therapeutic dose is also harmful to non-tumor tissues.Keywords: Euphorbia tirucalli, Ehrlich ascites tumor-bearing mice, Antitumor, Toxicity, Cardiac atrophy, Splenomegal
Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration
<p>Abstract</p> <p>Background</p> <p>Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (CO<sub>PAC</sub>) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (CO<sub>AP</sub>) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using CO<sub>PAC </sub>as the method of reference.</p> <p>Methods</p> <p>We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. CO<sub>PAC </sub>measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while CO<sub>AP </sub>values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman.</p> <p>Results</p> <p>A total of 164 coupled measurements were obtained. Absolute values of CO<sub>PAC </sub>ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between CO<sub>PAC </sub>and CO<sub>AP </sub>for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between CO<sub>PAC </sub>and CO<sub>AP </sub>was 49.3%. The bias between percentage changes in CO<sub>PAC </sub>(ΔCO<sub>PAC</sub>) and percentage changes in CO<sub>AP </sub>(ΔCO<sub>AP</sub>) for consecutive measurements was -0.70% ± 32.28%. CO<sub>PAC </sub>and CO<sub>AP </sub>showed a Pearson correlation coefficient of 0.58 (<it>p </it>< 0.01), while the correlation coefficient between ΔCO<sub>PAC </sub>and ΔCO<sub>AP </sub>was 0.46 (<it>p </it>< 0.01).</p> <p>Conclusion</p> <p>Although the CO<sub>AP </sub>algorithm shows a minimal bias with CO<sub>PAC </sub>over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03) failed to demonstrate an acceptable accuracy in comparison to the clinical standard of cardiac output determination.</p
Patient Acceptance of Noninvasive and Invasive Coronary Angiography
BACKGROUND: Noninvasive angiography using multislice computed tomography (MSCT) is superior to magnetic resonance imaging (MRI) for detection of coronary stenoses. We compared patient acceptance of these two noninvasive diagnostic tests and invasive conventional coronary angiography (Angio). METHODS AND FINDINGS: A total of 111 consecutive patients with suspected coronary artery disease underwent MSCT, MRI, and Angio. Subsequently, patient acceptance of the three tests was evaluated with questionnaires in all patients. The main acceptance variables were preparation and information prior to the test, degree of concern, comfort, degree of helplessness, pain (on visual analog scales), willingness to undergo the test again, and overall satisfaction. Preparation for each test was not rated significantly differently, whereas patients were significantly more concerned about Angio than the two noninvasive tests (p<0.001). No pain during MSCT, MRI, and Angio as assessed on visual analog scales (0 to 100) was reported by 99, 93, and 31 patients, respectively. Among the 82 patients who felt pain during at least one procedure, both CT (0.9±4.5) and MRI (5.2±16.6) were significantly less painful than Angio (24.6±23.4, both p<0.001). MSCT was considered significantly more comfortable (1.49±0.64) than MRI (1.75±0.81, p<0.001). In both the no-revascularization (55 patients) and the revascularization group (56 patients), the majority of the patients (73 and 71%) would prefer MSCT to MRI and Angio for future imaging of the coronary arteries. None of the patients indicated to be unwilling to undergo MSCT again. The major advantages patients attributed to MSCT were its fast, uncomplicated, noninvasive, and painless nature. CONCLUSIONS: Noninvasive coronary angiography with MSCT is considered more comfortable than MRI and both MSCT and MRI are less painful than Angio. Patient preference for MSCT might tip the scales in favor of this test provided that the diagnostic accuracy of MSCT can be shown to be high enough for clinical application
- …