104 research outputs found

    Temperature behavior of radiochromic poly(vinyl-alcohol)–glutaraldehyde Fricke gel dosimeters in practice

    Get PDF
    The use of synthetic gel matrices prepared with poly(vinyl-alcohol) (PVA) cross-linked by glutaraldehyde (GTA) contributed to enhance the interest toward radiochromic Fricke gel (FG) dosimeters. As it occurs in several chemical dosimeters, the response of PVA-GTA Fricke gels could be affected by temperature. Aim of this work is to study the dependence of the dosimetric properties of PVA-GTA Fricke gel dosimeters both on the irradiation temperature and on temperature changes possibly occurring between the irradiation and readout phases. Such effects were investigated by means of magnetic resonance imaging (MRI) and optical absorbance (OA) measurements. The results did not reveal any significant dependence of the sensitivity of the dosimeters on the irradiation temperature in the investigated interval 20\ub0C-35\ub0C. By contrast, auto-oxidation phenomena confirmed to be a critical aspect for FG dosimeters, also in case of use of PVA matrix. The extent such phenomena, that might impair the accuracy of dose estimations, proved to critically depend on the temperature at which FG dosimeters are subjected before and after irradiation, as well as on the duration of possible thermal-stress

    Performance of three model-based iterative reconstruction algorithms using a CT task-based image quality metric

    Full text link
    In this study we evaluated the task-based image quality of a low contrast clinical task for the abdomen protocol (e.g., pancreatic tumour) of three different CT vendors, exploiting three model-based iterative reconstruction (MBIR) levels. We used three CT systems equipped with a full, partial, advanced MBIR algorithms. Acquisitions were performed on a phantom at three dose levels. Acquisitions were reconstructed with a standard kernel, using filtered back projection algorithm (FBP) and three levels of the MBIR. The noise power spectrum (NPS), the normalized one (nNPS) and the task-based transfer function (TTF) were computed following the method proposed by the American Association of Physicists in Medicine task group report-233 (AAPM TG-233). Detectability index (d') of a small lesion (small feature; 100 HU and 5-mm diameter) was calculated using non-prewhitening with eye-filter model observer (NPWE).The nNPS, NPS and TTF changed differently depending on CT system. Higher values of d' were obtained with advanced-MBIR, followed by full-MBIR and partial-MBIR.Task-based image quality was assessed for three CT scanners of different vendors, considering a clinical question. Detectability can be a tool for protocol optimisation and dose reduction since the same dose levels on different scanners correspond to different d' values.Comment: 7 pages, 5 figures, 3 table

    dropwise condensation on superhydrophobic nanostructured surfaces literature review and experimental analysis

    Get PDF
    It is well established that the dropwise condensation (DWC) mode can lead up to significant enhancement in heat transfer coefficients as compared to the filmwise mode (FWC). Typically, hydrophobic surfaces are expected to promote DWC, while hydrophilic ones induce FWC. To this end, superhydrophobic surfaces, where a combination of low surface energy and surface texturing is used to enhance the hydrophobicity, have recently been proposed as a promising approach to promote dropwise condensation. An attractive feature of using superhydrophobic surfaces is to facilitate easy roll-off of the droplets as they form during condensation, thus leading to a significant improvement in the heat transfer associated with the condensation process. High droplet mobility can be obtained acting on the surface chemistry, decreasing the surface energy, and on the surface structure, obtaining a micro- or nano- superficial roughness. The first part of this paper will present a literature review of the most relevant works about DWC on superhydrophobic nanotextured substrates, with particular attention on the fabrication processes. In the second part, experimental data about DWC on superhydrophobic nanotextured samples will be analyzed. Particular attention will be paid to the effect of vapour velocity on the heat transfer. Results clearly highlight the excellent potential of nanostructured surfaces for application in flow condensation applications. However, they highlight the need to perform flow condensation experiments at realistic high temperature and saturation conditions in order to evaluate the efficacy of superhydrophobic surfaces for practically relevant pure vapor condensation applications

    Surfactant status and respiratory outcome in premature infants receiving late surfactant treatment.

    Get PDF
    BACKGROUND:Many premature infants with respiratory failure are deficient in surfactant, but the relationship to occurrence of bronchopulmonary dysplasia (BPD) is uncertain. METHODS:Tracheal aspirates were collected from 209 treated and control infants enrolled at 7-14 days in the Trial of Late Surfactant. The content of phospholipid, surfactant protein B, and total protein were determined in large aggregate (active) surfactant. RESULTS:At 24 h, surfactant treatment transiently increased surfactant protein B content (70%, p < 0.01), but did not affect recovered airway surfactant or total protein/phospholipid. The level of recovered surfactant during dosing was directly associated with content of surfactant protein B (r = 0.50, p < 0.00001) and inversely related to total protein (r = 0.39, p < 0.0001). For all infants, occurrence of BPD was associated with lower levels of recovered large aggregate surfactant, higher protein content, and lower SP-B levels. Tracheal aspirates with lower amounts of recovered surfactant had an increased proportion of small vesicle (inactive) surfactant. CONCLUSIONS:We conclude that many intubated premature infants are deficient in active surfactant, in part due to increased intra-alveolar metabolism, low SP-B content, and protein inhibition, and that the severity of this deficit is predictive of BPD. Late surfactant treatment at the frequency used did not provide a sustained increase in airway surfactant

    Computed tomography use in a large Italian region: trend analysis 2004-2014 of emergency and outpatient CT examinations in children and adults

    Get PDF
    Objectives: To analyse CT use in recent years in a high-density Italian area (\ub110 million inhabitants, including 1 million children), focusing on developing age. Methods: Retrospective analysis of records from HealthCare IT System, covering >400 hospitals and clinics. Description of CT use between 2004\u20132014 in emergency and outpatient care and assessment of radiation exposure trend. Results: Over 9 million scans were performed. Emergency procedures showed a global increase of 230 %, mainly head examinations. In the global outpatient setting, the annual number of CT scans/person increased \ub119 %. A moderate increase in CT examinations was observed in the developing age population, while a remarkable increase in dental, chest and abdominal procedures occurred for the 10- to 30-year age range. The increase in mean annual dose/capita in the global patient pool was approximately 42 %, increasing from 0.72\u20131.03 mSv. The population rate receiving an annual CT radiation dose/capita higher than 1 mSv tripled in the 11-year interval, increasing from 16\u201348 %. Conclusions: The remarkable increase in radiation exposure raises a special concern for teenagers and young adults, whose risk tends to be underestimated. The fivefold increase in dental CTs in the younger age groups requires further investigations. Key Points: \u2022 Literature highlights a remarkable increase in CT use over the last decades.\u2022 The paediatric age had higher exposure to X-ray risk.\u2022 A detailed retrospective analysis of more than 9 million scans was performed.\u2022 Dental, chest, abdominal procedures increased remarkably in 10- to 30-year age range.\u2022 This study raises concern about exposure for teenagers and young adults

    Surfactant phosphatidylcholine half-life and pool size measurements in premature baboons developing bronchopulmonary dysplasia

    Get PDF
    Because minimal information is available about surfactant metabolism in bronchopulmonary dysplasia, we measured half-lives and pool sizes of surfactant phosphatidylcholine in very preterm baboons recovering from respiratory distress syndrome and developing bronchopulmonary dysplasia, using stable isotopes, radioactive isotopes, and direct pool size measurements. Eight ventilated premature baboons received (2)H-DPPC (dipalmitoyl phosphatidylcholine) on d 5 of life, and radioactive (14)C-DPPC with a treatment dose of surfactant on d 8. After 14 d, lung pool sizes of saturated phosphatidylcholine were measured. Half-life of (2)H-DPPC (d 5) in tracheal aspirates was 28 +/- 4 h (mean +/- SEM). Half-life of radioactive DPPC (d 8) was 35 +/- 4 h. Saturated phosphatidylcholine pool size measured with stable isotopes on d 5 was 129 +/- 14 micro mol/kg, and 123 +/- 11 micro mol/kg on d 14 at autopsy. Half-lives were comparable to those obtained at d 0 and d 6 in our previous baboon studies. We conclude that surfactant metabolism does not change during the early development of bronchopulmonary dysplasia, more specifically, the metabolism of exogenous surfactant on d 8 is similar to that on the day of birth. Surfactant pool size is low at birth, increases after surfactant therapy, and is kept constant during the first 2 wk of life by endogenous surfactant synthesis. Measurements with stable isotopes are comparable to measurements with radioactive tracers and measurements at autopsy

    A multicenter evaluation of a deep learning software (LungQuant) for lung parenchyma characterization in COVID-19 pneumonia

    Get PDF
    BackgroundThe role of computed tomography (CT) in the diagnosis and characterization of coronavirus disease 2019 (COVID-19) pneumonia has been widely recognized. We evaluated the performance of a software for quantitative analysis of chest CT, the LungQuant system, by comparing its results with independent visual evaluations by a group of 14 clinical experts. The aim of this work is to evaluate the ability of the automated tool to extract quantitative information from lung CT, relevant for the design of a diagnosis support model.MethodsLungQuant segments both the lungs and lesions associated with COVID-19 pneumonia (ground-glass opacities and consolidations) and computes derived quantities corresponding to qualitative characteristics used to clinically assess COVID-19 lesions. The comparison was carried out on 120 publicly available CT scans of patients affected by COVID-19 pneumonia. Scans were scored for four qualitative metrics: percentage of lung involvement, type of lesion, and two disease distribution scores. We evaluated the agreement between the LungQuant output and the visual assessments through receiver operating characteristics area under the curve (AUC) analysis and by fitting a nonlinear regression model.ResultsDespite the rather large heterogeneity in the qualitative labels assigned by the clinical experts for each metric, we found good agreement on the metrics compared to the LungQuant output. The AUC values obtained for the four qualitative metrics were 0.98, 0.85, 0.90, and 0.81.ConclusionsVisual clinical evaluation could be complemented and supported by computer-aided quantification, whose values match the average evaluation of several independent clinical experts

    Analysis of a multicentre cloud-based CT dosimetric database: preliminary results

    Get PDF
    Background: To manage and analyse dosimetric data provided by computed tomography (CT) scanners from four Italian hospitals. Methods: A radiation dose index monitoring (RDIM) software was used to collect anonymised exams stored in a cloud server. Since hospitals use different names for the same procedure, digital imaging and communications in medicine (DICOM) tags more appropriate to describe exams were selected and associated to study common names (SCNs) from a radiology playbook according to scan region and use of contrast media. Retrospective analysis was carried out to describe population and to evaluate dosimetric indexes and inaccuracies associated with SCNs. Results: More than 400 procedures were clustered into 95 SCNs, but 78% of exams on adults were described with only 10 SCNs. Median values of dose-length product (DLP) and volumetric CT dose index (CTDIvol) for three analysed SCNs were in agreement with those previously published. The percentage of inaccuracies does not heavily affect the dosimetric analysis on the whole cloud, since variations in median values reached at most 8%. Conclusions: Implementation of a cloud-based RDIM software and related issues were described, showing the strength of the chosen playbook-based clustering and its usefulness for homogeneous data analysis. This approach may allow for optimisation actions, accurate assessment of the risk associated with radiation exposure, comparison of different facilities, and, last but not least, collection of information for the implementation of the 2013/59 Euratom Directive

    Brixsino High-Flux Dual X-Ray and THz Radiation Source Based on Energy Recovery Linacs

    Get PDF
    We present the conceptual design of a compact light source named BriXSinO. BriXSinO was born as demonstrator of the Marix project, but it is also a dual high flux radiation source Inverse Compton Source (ICS) of X-ray and Free-Electron Laser of THz spectral range radiation conceived for medical applications and general applied research. The accelerator is a push-pull CW-SC Energy Recovery Linac (ERL) based on superconducting cavities technology and allows to sustain MW-class beam power with almost just one hundred kW active power dissipation/consumption. ICS line produces 33 keV monochromatic X-Rays via Compton scattering of the electron beam with a laser system in Fabry-PĂ©rot cavity at a repetition rate of 100 MHz. The THz FEL oscillator is based on an undulator imbedded in optical cavity and generates THz wavelengths from 15 to 50 micron
    • …
    corecore