78 research outputs found

    Evaluation of Special Event Traffic Management: The Brickyard 400 Case Study

    Get PDF
    This paper reports on the anonymous tracking of Bluetooth enabled consumer electronic devices to measure the travel time, or space mean speed, of travelers. This sampling technique was deployed at six interstate locations and two signalized arterials in the Indianapolis, IN metropolitan area the week of the NASCAR Brickyard 400. The week prior to the race before data was also collected from a subset of those sites. The day of the race, almost 19,000 unique MAC address were captured at the eight locations. From that information real-time travel time estimates were provided to Indiana Department of Transportation (INDOT) mobile data terminals. After the race, the data was processed to obtain travel time plots and origin destination matrixes to provide a quantitative evaluation of race day traffic management operations. Selected reports and charts from that analysis are discussed in the paper

    Preoperative Factors and Three Year Weight Change in the Longitudinal Assessment of Bariatric Surgery (LABS) Consortium

    Get PDF
    BACKGROUND: Limited data guide the prediction of weight loss success or failure following bariatric surgery according to pre-surgery factors. There is significant variation in weight change following bariatric surgery and much interest in identifying pre-operative factors that may contribute to these differences. OBJECTIVE: This report evaluates the associations of a comprehensive set of baseline factors and three-year weight change. SETTING: Ten hospitals in six geographically diverse clinical centers in the United States. METHODS: PARTICIPANTS AND INTERVENTIONS: Adults undergoing a first bariatric surgical procedure as part of clinical care by participating surgeons were recruited between 2006 and 2009. Participants completed research assessments utilizing standardized and detailed data collection on over 100 preoperative and operative parameters for individuals undergoing Roux-en-Y gastric bypass (RYGB) and laparoscopic adjustable gastric banding (LAGB). Weight was measured 3 years following surgery. METHODS: MAIN OUTCOME MEASURES: Percent weight change for RYGB or LAGB from baseline to 3 years was analyzed as both a continuous and dichotomous outcome with cut points at 25% for RYGB and 10% for LAGB. Multivariable linear and logistic regression models were used to identify independent baseline predictors of the continuous and categorical outcomes, respectively. RESULTS: The median weight loss 3 years following surgery for RYGB (n=1513) participants was 31.5% (IQR: 24.6%–38.4%; range, 59.2% loss to 0.9% gain) of baseline weight and 16.0% (IQR: 8.1%–23.1%; range, 56.1% loss to 12.5% gain) for LAGB (n=509) participants. The median age was 46 years for RYGB and 48 years for LAGB; 80% of RYGB participants and 75% of LAGB participants were female; and the median baseline Body Mass Index (BMI) was 46 kg/m(2) for RYGB and 44 kg/m(2) for LAGB. For RYGB, Black participants lost 2.7% less weight compared to Whites and participants with diabetes at baseline had 3.7% less weight loss at year 3 than those without diabetes at baseline. There were small but statistically significant differences in weight change for RYGB in those with abnormal kidney function and current or recent smoking. For LAGB participants, those with a large band had 75% greater odds of experiencing less than 10% weight loss after adjusting for BMI and sex. CONCLUSIONS: Few baseline variables were associated with three year weight change and the effects were small. These results indicate that baseline variables have limited predictive value for an individual’s chance of a successful weight loss outcome following bariatric surgery. TRIAL REGISTRATION: NCT00465829, ClinicalTrials.go

    Book Review

    No full text

    Planned totally extraperitoneal laparoscopic Spigelian hernia repair.

    No full text
    A Spigelian hernia is a congenital defect in the tranversus aponeurosis fascia. Traditionally, an open anterior hernioplasty was used to repair these defects. Recently, laparoscopic approaches have been described. This report describes the first application of the totally extraperitoneal laparoscopic approach to a planned repair of a Spigelian hernia. The patient was a 62-year-old white female with a reducible left lower quadrant anterior abdominal wall bulge consistent with a Spigelian hernia. At the time of surgery, we exposed the posterior rectus fascia and modified our extraperitoneal inguinal hernia technique by passing the balloon dissector in a more lateral orientation. This created a unilateral preperitoneal space with adequate room for dissection and mesh fixation. The Spigelian defect was easily identified. Its preperitoneal fat contents were reduced, and a 5-mm laparoscopic tacking device was used to secure a piece of prolene mesh. The patient was discharged home with no complications. Placement of the mesh in the preperitoneal space avoids direct interaction of the mesh prosthesis and the intraperitoneal viscera. In conclusion, we find that a laparoscopic totally extraperitoneal approach is technically feasible and advantageous when a Spigelian hernia is diagnosed preoperatively

    Laparoscopic lateral L4-L5 disc exposure

    No full text
    Background: The anterior laparoscopic approach requires precarious dissection around the iliac vessels to expose the L4-L5 level. Furthermore, a retroperitoneal endoscopic approach to the L4-L5 level requires a technically demanding dissection to access the L5-S1 disc space. A unique lateral laparoscopic approach to the L4-L5 disc space allows concurrent access to the L5-S1 space while avoiding major dissection around the iliac vessels. This article describes this novel lateral approach and reviews the initial clinical outcomes. Methods: Between January 1999 and April 2000, five patients underwent laparoscopic lateral L4-L5 disc exposure at the Cleveland Clinic Foundation. All charts were reviewed retrospectively. Mean values ± standard deviation were determined for patient demographics and operative characteristics. A standard five-port laparoscopic technique was used. The sigmoid colon was retracted medially with an endoloop. The retroperitoneum was entered and the ureter and left iliac artery were retracted medially, whereas the psoas was retracted laterally. Fluoroscopy delineated the L4-L5 disc space allowing discectomy and cage insertion. Postoperatively, subjective patient satisfaction was obtained and radiologic evidence of fusion was assessed. Results: All five patients were males, with a mean age of 47.4 ± 7 years and a body mass index of 30 ± 6 kg/m2. Four patients had an L4-L5 and L5-S1 fusion and one patient had an L4-L5 and L3-L4 fusion. Mean operative time was 349 ± 32 min, with a mean blood loss of 210 ± 74 cc. There were no intraoperative complications and no conversions, and postoperatively all patients were started on a clear liquid diet on postoperative day 1. The mean length of stay was 3.4 ±0.9 days. Patients returned to work in a mean of 12 ± 7 weeks. All patients had evidence of fusion on their radiologic follow-up. Four patients were pain free, whereas one patient required intermittent narcotics at 1-year follow-up. Conclusions: For multilevel fusions including the L4-L5 disc space, the lateral laparoscopic exposure is a safe and efficacious procedure allowing simultaneous access to multiple disc spaces while avoiding the sympathetic chain, ureter, and major vascular structures. The lateral approach affords excellent exposure for accurate deployment of the appropriate orthopedic hardware
    • …
    corecore