298 research outputs found

    New Physics Signals through CP Violation in B -> rho,pi

    Full text link
    We describe here a method for detecting physics beyond the standard model via CP violation in B->rho,pi decays. Using a Dalitz-plot analysis to obtain alpha, along with an analytical extraction of the various tree (T) and penguin (P) amplitudes, we obtain a criterion for the absence of new physics (NP). This criterion involves the comparison of the measured |P/T| ratio with its value as predicted by QCD factorization. We show that the detection of NP via this method has a good efficiency when compared with the corresponding technique using B->pi,pi decays.Comment: 8 pages, 4 figures, talk given at MRST 2004: From Quarks to Cosmology, Concordia University, Montreal, May 200

    Correlations Between Individuals' Characteristics and Spinal Stiffness in Individuals With and Without Back Pain: A Combined Analysis of Multiple Data Sets.

    Get PDF
    OBJECTIVE: The purpose of this study was to describe the correlations between individual characteristics and spinal stiffness as measured with different spinal stiffness measurement devices in individuals with and without back pain. METHODS: A secondary analysis of 3 adult data sets obtained using 3 different devices, in 2 spinal regions, from a total of 5 separate cross-sectional studies was conducted. Differences in spinal stiffness between men and women and in the strength of correlations among spinal stiffness and age and anthropometric characteristics were evaluated using either the t test for independent samples, Pearson's correlation coefficient, or Kendall's τ rank correlation coefficient. RESULTS: As expected, results varied between data sets; however, few factors had consistent correlations. Specifically, spinal stiffness was significantly lower in women than men in all 3 data sets. Height was positively correlated with spinal stiffness across all data sets. Although weight was correlated with thoracic stiffness, its correlation with lumbar stiffness varied. In 2 data sets, body mass index was inversely associated with lumbar spinal stiffness, whereas results from the thoracic spine region revealed a positive correlation. The results for 1 data set suggest that physiological measurement evaluating body weight distribution may also affect spinal stiffness; however, the specific correlation remains unclear. CONCLUSION: Despite data set differences, significant correlations were observed, indicating that participants' characteristics appear to affect spinal stiffness measurement

    Modeling Rare Species Distribution at the Edge: The Case for the Vulnerable Endemic Pyrenean Desman in France

    Get PDF
    The endemic Pyrenean Desman (Galemys pyrenaicus) is an elusive, rare, and vulnerable species declining over its entire and narrow range (Spain, Portugal, France, and Andorra). The principal set of conservation measures in France is a 5-years National Action Plan based on 25 conservation actions. Priority is given to update its present distribution and develop tools for predictive distribution models. We aim at building the first species distribution model and map for the northern edge of the range of the Desman and confronting the outputs of the model to target conservation efforts in the context of environmental change. Contrasting to former comparable studies, we derive a simpler model emphasizing the importance of factors linked to precipitation and not to the temperature. If temperature is one of the climate change key factors, depicted shrinkage in Desman distribution could be lower or null at the northern (French) edge suggesting thus a major role for this northern population in terms of conservation of the species. Finally, we question the applied issue of temporal and spatial transferability for such environmental favourability models when it is made at the edge of the distribution range

    Clinicians' Ability to Detect a Palpable Difference in Spinal Stiffness Compared With a Mechanical Device.

    Get PDF
    OBJECTIVE: The purpose of this study was to quantify the threshold at which clinicians can detect a difference in spinal stiffness of the thoracic and lumbar spine via palpation and then determine if this detection threshold would affect a clinician's ability to identify changes in spinal stiffness as measured by an objective instrument. METHODS: In this study, the threshold at which a change in spinal stiffness was detected was quantified in 12 experienced clinicians (physical therapists and doctors of chiropractic) by changing the differential stiffness in 2 inflatable targets until the clinician could no longer identify which was stiffer. In the second part of the study, clinicians then were asked to palpate pre-identified pairs of vertebrae in an asymptomatic volunteer and to identify the stiffer of the pair (T7 and L3, T7 and L4, L3 and L4), and the biomechanical stiffness of each vertebral pair was quantified objectively by a validated instrument. RESULTS: The mean stiffness detection threshold for the clinicians was 8%. Objective measurement of the stiffness differential between vertebral pairs was 30% for T7* and L3, 20% for T7* and L4, and 10% for L3* and L4 (*denotes the stiffer of the pair). Ten of 12 clinicians correctly identified T7 as stiffer when compared with L3 and T7 as stiffer than L4. Alternatively, when the differential vertebral pair stiffness was similar to the stiffness detection threshold (~8%), clinicians were less successful in identifying the stiffer vertebra of the pair; 4 of 12 clinicians correctly identified L3 as being stiffer compared with L4. CONCLUSION: These results suggest that the physiological limits of human palpation may limit the ability of clinicians to identify small alterations in spine stiffness

    Spinal mobilization force-time characteristics:A scoping literature review

    Get PDF
    Abstract Background Spinal mobilization (SMob) is often included in the conservative management of spinal pain conditions as a recommended and effective treatment. While some studies quantify the biomechanical (kinetic) parameters of SMob, interpretation of findings is difficult due to poor reporting of methodological details. The aim of this study was to synthesise the literature describing force-time characteristics of manually applied SMob. Methods This study is reported in accordance with the Preferred Reporting Items for Scoping Reviews (PRISMA-ScR) statement. Databases were searched from inception to October 2022: MEDLINE (Ovid), Embase, CINAHL, ICL, PEDro and Cochrane Library. Data were extracted and reported descriptively for the following domains: general study characteristics, number of and characteristics of individuals who delivered/received SMob, region treated, equipment used and force-time characteristics of SMob. Results There were 7,607 records identified and of these, 36 (0.5%) were included in the analysis. SMob was delivered to the cervical spine in 13 (36.1%), the thoracic spine in 3 (8.3%) and the lumbopelvic spine in 18 (50.0%) studies. In 2 (5.6%) studies, spinal region was not specified. For SMob applied to all spinal regions, force-time characteristics were: peak force (0-128N); duration (10-120s); frequency (0.1–4.5Hz); and force amplitude (1-102N). Conclusions This study reports considerable variability of the force-time characteristics of SMob. In studies reporting force-time characteristics, SMob was most frequently delivered to the lumbar and cervical spine of humans and most commonly peak force was reported. Future studies should focus on the detailed reporting of force-time characteristics to facilitate the investigation of clinical dose-response effects

    Distinguishing problematic from nonproblematic postsurgical pain: A pain trajectory analysis after total knee arthroplasty

    Get PDF
    The goal of this study was to follow a cohort of patients undergoing total knee arthroplasty over time to: (1) identify and describe the various pain trajectories beginning preoperatively and for up to 12 months after surgery, (2) identify baseline predictors of trajectory group membership, and (3) identify trajectory groups associated with poor psychosocial outcomes 12 months after surgery. One hundred seventy-three participants (female = 85 [49%]; mean age [years] = 62.9, SD = 6.8) completed pain and psychological questionnaires and functional performance tests preoperatively and 4 days, 6 weeks, and 3 and 12 months after total knee arthroplasty. Using growth mixture modeling, results showed that a 4-group model, with a quadratic slope and baseline pain data predicting trajectory group membership, best fit the data (Akaike information criterion = 2772.27). The first 3 pain trajectories represent various rates of recovery ending with relatively low levels of pain 12 months after surgery. Group 4, the constant high pain group, comprises patients who have a neutral or positive pain slope and do not show improvement in their pain experience over the first year after surgery. This model suggests that preoperative pain levels are predictive of pain trajectory group membership and moderate preoperative pain, as opposed to low or high pain, is a risk factor for a neutral or positive pain trajectory postoperatively. Consistent with previous studies, these results show that postoperative pain is not a homogeneous condition and point to the importance of examining intraindividual pain fluctuations as they relate to pain interventions and prevention strategies.M. G. Page´ is supported by a Canada Graduate Scholarship— Doctoral Award from the Canadian Institutes of Health Research (CIHR) and is a recipient of a Lillian-Wright Maternal-Child Health Scholarship from York University, a trainee member of Pain in Child Health and a CIHR Strategic Training Fellow in Pain: Molecules to Community. J. Katz is supported by a CIHR Canada Research Chair in Health Psychology at York University. H. A. Clarke is supported by a Merit Award from the Department of Anaesthesia at the University of Toronto and also supported by the STAGE Training Program in Genetic Epidemiology from the CIHR. The remaining authors have no conflicts of interest to declare

    Just how much does it cost? A cost study of chronic pain following cardiac surgery

    Get PDF
    Objective: The study objective was to determine use of pain-related health care resources and associated direct and indirect costs over a two-year period in cardiac surgery patients who developed chronic post-surgical pain (CPSP). Methods: This multicentric observational prospective study recruited patients prior to cardiac surgery; these patients completed research assistant-administered questionnaires on pain and psychological characteristics at 6, 12 and 24 months post-operatively. Patients reporting CPSP also completed a one-month pain care record (PCR) (self-report diary) at each follow-up. Data were analyzed using descriptive statistics, multivariable logistic regression models, and generalized linear models with log link and gamma family adjusting for sociodemographic and pain intensity. Results: Out of 1,247 patients, 18%, 13%, and 9% reported experiencing CPSP at 6, 12, and 24 months, respectively. Between 16% and 28% of CPSP patients reported utilizing health care resources for their pain over the follow-up period. Among all CPSP patients, mean monthly pain-related costs were CAN$207 at 6 months and significantly decreased thereafter. More severe pain and greater levels of pain catastrophizing were the most consistent predictors of health care utilization and costs. Discussion: Health care costs associated with early management of CPSP after cardiac surgery seem attributable to a minority of patients and decrease over time for most of them. Results are novel in that they document for the first time the economic burden of CPSP in this population of patients. Longer follow-up time that would capture severe cases of CPSP as well as examination of costs associated with other surgical populations are warranted. Summary: Economic burden of chronic post-surgical pain may be substantial but few patients utilize resources. Health utilization and costs are associated with pain and psychological characteristics

    Investigation of the factors influencing spinal manipulative therapy force transmission through the thorax: A cadaveric study

    Get PDF
    Abstract Spinal manipulative therapy (SMT) clinical effects are believed to be linked to its force–time profile characteristics. Previous studies have revealed that the force measured at the patient-table interface is most commonly greater than the one applied at the clinician-patient interface. The factors explaining this force amplification remains unclear. Objective To determine the difference between the force applied to a cadaveric specimen’s thoracic spine and the resulting force measured by a force-sensing table, as well as to evaluate the relationship between this difference and both the SMT force–time characteristics and the specimens’ characteristics. Methods Twenty-five SMTs with different force–time profiles were delivered by an apparatus at the T7 vertebra of nine human cadaveric specimens lying prone on a treatment table equipped with a force plate. The difference between the force applied by the apparatus and the resulting force measured by the force plate was calculated in absolute force (Fdiff) and as the percentage of the applied force (Fdiff%). Kinematics markers were inserted into T6 to T8 spinous and transverse processes to evaluate vertebral displacements during the SMT thrusts. Mixed-effects linear models were run to evaluate the variance in Fdiff and Fdiff% explained by SMT characteristics (peak force, thrust duration and force application rate), T6 to T8 relative and total displacements, and specimens’ characteristics (BMI, height, weight, kyphosis angle, thoracic thickness). Results Sixty percent of the trials showed lower force measured at the force plate than the one applied at T7. Fdiff¸ was significantly predicted (R2marginal = 0.54) by peak force, thrust duration, thoracic thickness and T6–T7 relative displacement in the z-axis (postero-anterior). Fdiff% was significantly predicted (R2marginal = 0.56) by force application rate, thoracic thickness and total T6 displacements. For both dependant variables, thoracic thickness showed the highest R2marginal out of all predictors. Conclusion Difference in force between the clinician-patient and the patient-table interfaces is influenced by SMT force–time characteristics and by thoracic thickness. How these differences in force are associated with vertebral displacements remains unclear. Although further studies are needed, clinicians should consider thorax thickness as a possible modulator of forces being transmitted through it during prone SMT procedures

    Early quantitative coronary angiography of saphenous vein grafts for coronary artery bypass grafting harvested by means of open versus endoscopic saphenectomy: a prospective randomized trial

    Get PDF
    AbstractObjectiveEndoscopic saphenectomy is associated with a decreased incidence of wound complications without an increase in histologic trauma or endothelial dysfunction in published reports. Concern remains about the patency of saphenous vein grafts harvested endoscopically and the development of early intimal hyperplasia. The purpose of this study was to compare early quantitative coronary analysis of saphenous vein grafts used for coronary artery bypass grafting harvested with the open versus endoscopic techniques.MethodsForty patients undergoing primary coronary artery bypass grafting surgery with at least 1 saphenous vein graft were randomized preoperatively to open versus endoscopic saphenectomy with bipolar cauterization of side branches. Quantitative coronary angiography was performed a mean of 3 months (range, 1-9 months) after the operation.ResultsThere was no statistically significant difference in the patency rates of internal thoracic artery grafts between the open and endoscopic groups and no statistically significant difference in the patency rates of saphenous vein grafts between both groups (85.2% vs 84.4%, P = .991). Quantitative coronary angiography showed no difference in graft stenosis (≥50% of the internal diameter of the graft) in the body of the saphenous vein grafts in the open versus endoscopic saphenectomy groups (3.7% vs 0%, P = .280).ConclusionAngiographic appearance and patency rates of saphenous vein grafts harvested with the endoscopic technique are similar to those of saphenous vein grafts harvested with the open technique. These results support the use of endoscopic saphenectomy because of the known lower incidence of wound and infectious complications and superior functional results
    • …
    corecore