46 research outputs found
Dinosaur egg structure investigated by MRI
<p>In July 1993, the Hunterian Museum of the University of Glasgow was offered a sandstone block with a clutch of intact dinosaur eggs, from Hunan Province, China. Later, a number of single eggs were also acquired.</p>
<p>An inter-disciplinary project began to investigate the structure of these eggs. Investigations carried out included egg shell structure analysis, protein analysis, and a program of imaging including CT|, neutron radiography, and MRI.</p>
In this poster, the results of imaging the eggs in two commercial high field MRI scanners based at Glasgow hospitals, are presented. The MR scanners are Seimens 1.0 T Impact and 1.5 T Magnetom
The influence of MRI scan position on patients with oropharyngeal cancer undergoing radical radiotherapy
<p>Background: The purpose of this study was to demonstrate how magnetic resonance imaging (MRI) patient position protocols influence registration quality in patients with oropharyngeal cancer undergoing radical radiotherapy and the consequences for gross tumour volume (GTV) definition and radiotherapy planning.</p>
<p>Methods and materials: Twenty-two oropharyngeal patients underwent a computed tomography (CT), a diagnostic MRI (MRID) and an MRI in the radiotherapy position within an immobilization mask (MRIRT). Clinicians delineated the GTV on the CT viewing the MRID separately (GTVC); on the CT registered to MRID (GTVD) and on the CT registered to MRIRT (GTVRT). Planning target volumes (PTVs) were denoted similarly. Registration quality was assessed by measuring disparity between structures in the three set-ups. Volumetric modulated arc therapy (VMAT) radiotherapy planning was performed for PTVC, PTVD and PTVRT. To determine the dose received by the reference PTVRT, we optimized for PTVC and PTVD while calculating the dose to PTVRT. Statistical significance was determined using the two-tailed Mann–Whitney or two-tailed paired student t-tests.</p>
<p>Results: A significant improvement in registration accuracy was found between CT and MRIRT versus the MRID measuring distances from the centre of structures (geometric mean error of 2.2 mm versus 6.6 mm). The mean GTVC (44.1 cm3) was significantly larger than GTVD (33.7 cm3, p value = 0.027) or GTVRT (30.5 cm3, p value = 0.014). When optimizing the VMAT plans for PTVC and investigating the mean dose to PTVRT neither the dose to 99% (58.8%) nor 95% of the PTV (84.7%) were found to meet the required clinical dose constraints of 90% and 95% respectively. Similarly, when optimizing for PTVD the mean dose to PTVRT did not meet clinical dose constraints for 99% (14.9%) nor 95% of the PTV (66.2%). Only by optimizing for PTVRT were all clinical dose constraints achieved.</p>
<p>Conclusions: When oropharyngeal patients MRI scans are performed in the radiotherapy position there are significant improvements in CT-MR image registration, target definition and PTV dose coverage.</p>
Assessing the image quality of pelvic MR images acquired with a flat couch for radiotherapy treatment planning
OBJECTIVES: To improve the integration of MRI with radiotherapy treatment planning, our department fabricated a flat couch top for our MR scanner. Setting up using this couch top meant that the patients were physically higher up in the scanner and, posteriorly, a gap was introduced between the patient and radiofrequency coil. METHODS: Phantom measurements were performed to assess the quantitative impact on image quality. A phantom was set up with and without the flat couch insert in place, and measurements of image uniformity and signal to noise were made. To assess clinical impact, six patients with pelvic cancer were recruited and scanned on both couch types. The image quality of pairs of scans was assessed by two consultant radiologists. RESULTS: The use of the flat couch insert led to a drop in image signal to noise of approximately 14%. Uniformity in the anteroposterior direction was affected the most, with little change in right-to-left and feet-to-head directions. All six patients were successfully scanned on the flat couch, although one patient had to be positioned with their arms by their sides. The image quality scores showed no statistically significant change between scans with and without the flat couch in place. CONCLUSION: Although the quantitative performance of the coil is affected by the integration of a flat couch top, there is no discernible deterioration of diagnostic image quality, as assessed by two consultant radiologists. Although the flat couch insert moved patients higher in the bore of the scanner, all patients in the study were successfully scanned
Study of diffusion weighted MRI as a predictive biomarker of response during radiotherapy for high and intermediate risk squamous cell cancer of the oropharynx: The MeRInO study
Introduction and background:
A significant proportion of patients with intermediate and high risk squamous cell cancer of the oropharynx (OPSCC) continue to relapse locally despite radical chemoradiotherapy (CRT). The toxicity of the current combination of intensified dose per fraction radiotherapy and platinum based chemotherapy limits further uniform intensification. If a predictive biomarker for outcomes from CRT can be identified during treatment then individualised and adaptive treatment strategies may be employed.
Methods/design:
The MeRInO study is a prospective observational imaging study of patients with intermediate and high risk, locally advanced OPSCC receiving radical RT or concurrent CRT Patients undergo diffusion weighted MRI prior to treatment (MRI_1) and during the third week of RT (MRI_2). Apparent diffusion coefficient (ADC) measurements will be made on each scan for previously specified target lesions (primary and lymph nodes) and change in ADC calculated. Patients will be followed up and disease status for each target lesion noted. The primary aim of the MeRInO study is to determine the threshold change in ADC from baseline to week 3 of RT that may identify the sub-group of non-responders during treatment.
Discussion:
The use of DW-MRI as a predictive biomarker during RT for SCC H&N is in its infancy but studies to date have found that response to treatment may indeed be predicted by comparison of DW-MRI carried out before and during treatment. However, previous studies have included all sub-sites and biological sub-types. Establishing ADC thresholds that predict for local failure is an essential step towards using DW-MRI to improve the therapeutic ratio in treating SCC H&N. This would be done most robustly in a specific H&N sub-site and in sub-types with similar biological behaviour. The MeRInO study will help establish these thresholds in OPSCC
EP-1137 DW MRI as biomarker of response during RT for intermed/high risk SCC oropharynx : a feasibility study
Despite radical chemo-radiotherapy (CRT), many patients with intermediate and high risk SCC oropharynx (OPSCC) relapse. Treatment related toxicity limits further uniform intensification across the patient group. If a predictive biomarker for outcomes from CRT can be identified during treatment, individualised and adaptive treatment strategies may be employed for the non-responders. This is the 1st study to use DW MRI for early response assessment in a specific H&N sub-site with sub-type of similar biological behaviour
fMRI scanner noise interaction with affective neural processes
The purpose of the present study was the investigation of interaction effects between functional MRI scanner noise and affective neural processes. Stimuli comprised of psychoacoustically balanced musical pieces, expressing three different emotions (fear, neutral, joy). Participants (N=34, 19 female) were split into two groups, one subjected to continuous scanning and another subjected to sparse temporal scanning that features decreased scanner noise. Tests for interaction effects between scanning group (sparse/quieter vs continuous/noisier) and emotion (fear, neutral, joy) were performed. Results revealed interactions between the affective expression of stimuli and scanning group localized in bilateral auditory cortex, insula and visual cortex (calcarine sulcus). Post-hoc comparisons revealed that during sparse scanning, but not during continuous scanning, BOLD signals were significantly stronger for joy than for fear, as well as stronger for fear than for neutral in bilateral auditory cortex. During continuous scanning, but not during sparse scanning, BOLD signals were significantly stronger for joy than for neutral in the left auditory cortex and for joy than for fear in the calcarine sulcus. To the authors' knowledge, this is the first study to show a statistical interaction effect between scanner noise and affective processes and extends evidence suggesting scanner noise to be an important factor in functional MRI research that can affect and distort affective brain processes
NMR microscopy at 500MHz
SIGLEAvailable from British Library Document Supply Centre- DSC:D96392 / BLDSC - British Library Document Supply CentreGBUnited Kingdo