319 research outputs found

    Atypical gaze-following behaviour in infants with congenital heart disease

    Full text link
    BACKGROUND Neurodevelopmental impairments are the most prevalent non-cardiac long-term sequelae in children with complex congenital heart disease (CHD). Deficits include the social-emotional and social-cognitive domains. Little is known about the predecessors of social-cognitive development in infants with CHD during the first year of life. Gaze-following behaviour can be used to measure early social-cognitive abilities. AIMS To assess gaze-following development in infants with CHD compared to healthy controls. STUDY DESIGN Prospective cohort study. PARTICIPANTS Twenty-three infants who underwent neonatal correction for CHD and 84 healthy controls. OUTCOME MEASURES Gaze-following behaviour was assessed by eye tracking at 6 and 12 months. Difference scores for first fixation, fixation frequency and fixation duration towards the gaze-cued object were calculated across 6 trials and compared between groups at both testing time points while adjusting for known confounders. Linear mixed models were calculated to assess the longitudinal trajectory of gaze-following development while accounting for the nested and dependent data structure. RESULTS At 6 months, no difference in gaze-following behaviour between CHD and healthy controls was found. At 12 months, fixation frequency towards the gaze-cued was lower and looking duration was shorter in CHD compared to controls (p = 0.0077; p = 0.0068). Infants with CHD showed less increase with age in the fixation frequency towards the congruent object (p = 0.041) compared to controls. CONCLUSION During the first year of life, gaze-following development diverges in infants with CHD compared to healthy controls. Further research is needed to investigate the clinical relevance of these findings and the association with later social-cognitive development

    Perioperative Course and Socioeconomic Status Predict Long-Term Neurodevelopment Better Than Perioperative Conventional Neuroimaging in Children with Congenital Heart Disease.

    Get PDF
    The objective of the study was to compare the use of neonatal conventional brain magnetic resonance imaging (MRI) with that of clinical factors and socioeconomic status (SES) to predict long-term neurodevelopment in children with severe congenital heart disease (CHD). In this prospective cohort study, perioperative MRIs were acquired in 57 term-born infants with CHD undergoing cardiopulmonary bypass surgery during their first year of life. Total brain volume (TBV) was measured using an automated method. Brain injury severity (BIS) was assessed by an established scoring system. The neurodevelopmental outcome was assessed at 6 years using standardized test batteries. A multiple linear regression model was used for cognitive and motor outcomes with postoperative TBV, perioperative BIS, CHD complexity, length of hospital stay, and SES as covariates. CHD diagnoses included univentricular heart defect (n = 15), transposition of the great arteries (n = 33), and acyanotic CHD (n = 9). Perioperative moderate-to-severe brain injury was detected in 15 (26%) patients. The total IQ was similar to test norms (P = .11), whereas the total motor score (P < .001) was lower. Neither postoperative TBV nor perioperative BIS predicted the total IQ, but SES (P < .001) and longer hospital stay (P = .004) did. No factor predicted the motor outcome. Although the predictive value of neonatal conventional MRIs for long-term neurodevelopment is low, duration of hospital stay and SES better predict the outcome in this CHD sample. These findings should be considered in initiating early therapeutic support

    Cardiac output measurement in children: comparison of AesculonÂź cardiac output monitor and thermodilution

    Get PDF
    Background We compared cardiac output (CO) measurements by the non-invasive electrical velocimetry (Aesculon¼) monitor with the pulmonary artery catheter (PAC) thermodilution method in children. Methods CO values using the Aesculon¼ monitor and PAC thermodilution were simultaneously recorded during cardiac catheterization in children. Measurements were performed under general anaesthesia. To compare, three consecutive measurements for each patient within 3 min were obtained. The means of the three values were compared using simple regression and Bland-Altman analysis. Data were presented as mean (sd). A mean percentage of <30% was defined to indicate clinical useful reliability of the Aesculon¼ monitor. Results A total of 50 patients with a median (range) age of 7.5 (0.5-16.5) yr were enrolled in the study. Mean CO values were 3.7 (1.5) litre min−1 (PAC thermodilution) and 3.1 (1.7) litre min−1 (Aesculon¼ monitor). Analysis for CO measurement showed a good correlation between the two methods (r=0.894; P<0.0001). The bias between the two methods was 0.66 litre min−1 with a precision of 1.49 litre min−1. The mean percentage error for CO measurements was 48.9% for the Aesculon¼ monitor when compared with PAC thermodilution. Conclusions Electrical velocimetry using the Aesculon¼ monitor did not provide reliable CO values when compared with PAC thermodilution. Whether the Aesculon¼ monitor can be used as a CO trend monitor has to be assessed by further investigations in patients with changing haemodynamic

    Tracheal tube-tip displacement in children during head-neck movement—a radiological assessment

    Get PDF
    Background. Aims of this study were to assess the maximum displacement of tracheal tube tip during head-neck movement in children, and to evaluate the appropriateness of the intubation depth marks on the Microcuff Paediatric Endotracheal Tube regarding the risk of inadvertent extubation and endobronchial intubation. Methods. We studied children, aged from birth to adolescence, undergoing cardiac catheterization. The patients' tracheas were orally intubated and the tracheal tubes positioned with the intubation depth mark at the level of the vocal cords. The tracheal tube tip-to-carina distances were fluoroscopically assessed with the patient supine and the head-neck in 30° flexion, 0° neutral position and 30° extension. Results. One hundred children aged between 0.02 and 16.4 yr (median 5.1 yr) were studied. Maximum tracheal tube-tip displacement after head-neck 30° extension and 30° flexion demonstrated a linear relationship to age [maximal upward tube movement (mm)=0 0.71×age (yr)+9.9 (R2=0.893); maximal downward tube movement (mm)=0.83×age (yr)+9.3 (R2=0.949)]. Maximal tracheal tube-tip downward displacement because of head-neck flexion was more pronounced than upward displacement because of head-neck extension. Conclusions. The intubation depth marks were appropriate to avoid inadvertent tracheal extubation and endobronchial intubation during head-neck movement in all patients. However, during head-neck extension the tracheal tube cuff may become positioned in the subglottic region and should be re-adjusted when the patient remains in this position for a longer tim

    The development of a new blood substitute

    Get PDF
    Trattasi di un sommario pubblicato online nel sito dell'Agenzia di divulgazione scientifica Atlas of Science, AoS Nordic AB, Moscow, Russia, riguardante l'impiego di nuovi sostituti del sangu

    Establishing a pre-clinical growing animal model to test a tissue engineered valved pulmonary conduit

    Get PDF
    Background: Many valvular pathologies of the heart may be only sufficiently treated by replacement of the valve if a reconstruction is not feasible. However, structural deterioration, thrombosis with thromboembolic events and infective endocarditis are commonly encountered complications over time and often demand a re-operation. In congenital heart disease the lack of small diameter valves with the potential to grow poses additional challenges and limits treatment options to homo- or xenograft implants. Methods: In this study, a chronic sheep model (24 months follow-up), a self-constructed valved conduit was created out of a tissue engineered (TE) patch (CorMatrixÂź Cardiovascular, Inc, USA) and implanted in orthotopic right ventricular (RV)-pulmonary artery (PA) position. Thereafter, the sheep were regularly monitored by clinical, laboratory and echocardiographic examinations to evaluate cardiac function and the implanted RV-PA-conduit. Discussion: Here, we summarize the study protocol and our experiences during the perioperative phase and the follow up period and explain how we constructed a valved conduit out of a commercially available TE patch. Trial registration: License number: ZH 284/14

    Phytochemical investigations of three Rhodocodon (Hyacinthaceae Sensu APG II) species

    Get PDF
    The genus Rhodocodon (Hyacinthaceae sensu APG II) is endemic to Madagascar and its phytochemistry has not been described previously. The phytochemistry of three species in this genus has been investigated and eight compounds, including three bufadienolides (compounds 1, 4, and 5), a norlignan (2), and four homoisoflavonoids (compounds 3 and 6-8) have been isolated and identified. Compounds 1-3 and 6-8 have not been described previously. The COX-2 inhibitory activity of compound 6 and compound 7 acetate (compound 7A) were investigated on isolated colorectal cancer cells. Compounds 6 and 7A inhibited COX-2 by 10% and 8%, respectively, at a concentration of 12.5 M compared to 12% for 1 mM aspirin (the positive control)
    • 

    corecore