720 research outputs found
High-Resolution spectroscopy of the low-mass X-ray binary EXO 0748-67
We present initial results from observations of the low-mass X-ray binary EXO
0748-67 with the Reflection Grating Spectrometer on board the XMM-Newton
Observatory. The spectra exhibit discrete structure due to absorption and
emission from ionized neon, oxygen, and nitrogen. We use the quantitative
constraints imposed by the spectral features to develop an empirical model of
the circumsource material. This consists of a thickened accretion disk with
emission and absorption in the plasma orbiting high above the binary plane.
This model presents challenges to current theories of accretion in X-ray binary
systems.Comment: 5 pages, 4 figures, accepted by A&A letters, XMM special issu
On the Putative Detection of z>0 X-ray Absorption Features in the Spectrum of Markarian 421
In a series of papers, Nicastro et al. have reported the detection of z>0
OVII absorption features in the spectrum of Mrk421 obtained with the Chandra
Low Energy Transmission Grating Spectrometer (LETGS). We evaluate this result
in the context of a high quality spectrum of the same source obtained with the
Reflection Grating Spectrometer (RGS) on XMM-Newton. The data comprise over
955ks of usable exposure time and more than 26000 counts per 50 milliAngstrom
at 21.6 Angstroms. We concentrate on the spectrally clean region (21.3 < lambda
< 22.5 Angstroms) where sharp features due to the astrophysically abundant OVII
may reveal an intervening, warm--hot intergalactic medium (WHIM). We do not
confirm detection of any of the intervening systems claimed to date. Rather, we
detect only three unsurprising, astrophysically expected features down to the
Log(N_i)~14.6 (3 sigma) sensitivity level. Each of the two purported WHIM
features is rejected with a statistical confidence that exceeds that reported
for its initial detection. While we can not rule out the existence of fainter,
WHIM related features in these spectra, we suggest that previous discovery
claims were premature. A more recent paper by Williams et al. claims to have
demonstrated that the RGS data we analyze here do not have the resolution or
statistical quality required to confirm or deny the LETGS detections. We show
that our careful analysis resolves the issues encountered by Williams et al.
and recovers the full resolution and statistical quality of the RGS data. We
highlight the differences between our analysis and those published by Williams
et al. as this may explain our disparate conclusions.Comment: 19 pages/7 figures/4 tables. 060424 submitted to ApJ 060522
re-submitted following ApJ reques
A New Comprehensive 2-D Model of the Point Spread Functions of the XMM-Newton EPIC Telescopes : Spurious Source Suppression and Improved Positional Accuracy
We describe here a new full 2-D parameterization of the PSFs of the three
XMM-Newton EPIC telescopes as a function of instrument, energy, off-axis angle
and azimuthal angle, covering the whole field-of-view of the three EPIC
detectors. It models the general PSF envelopes, the primary and secondary
spokes, their radial dependencies, and the large-scale azimuthal variations.
This PSF model has been constructed via the stacking and centering of a large
number of bright, but not significantly piled-up point sources from the full
field-of-view of each EPIC detector, and azimuthally filtering the resultant
PSF envelopes to form the spoke structures and the gross azimuthal shapes
observed. This PSF model is available for use within the XMM-Newton Science
Analysis System via the usage of Current Calibration Files XRTi_XPSF_0011.CCF
and later versions. Initial source-searching tests showed substantial
reductions in the numbers of spurious sources being detected in the wings of
bright point sources. Furthermore, we have uncovered a systematic error in the
previous PSF system, affecting the entire mission to date, whereby returned
source RA and Dec values are seen to vary sinusoidally about the true position
(amplitude ~0.8") with source azimuthal position. The new PSF system is now
available and is seen as a major improvement with regard to the detection of
spurious sources. The new PSF also largely removes the discovered astrometry
error and is seen to improve the positional accuracy of EPIC. The modular
nature of the PSF system allows for further refinements in the future.Comment: Accepted for publication in A&A. 15 pages, 13 figures (some of
reduced quality). A full-resolution version is available at
http://www.star.le.ac.uk/~amr30/amr_PSFpaper.pd
- …