1,365 research outputs found

    Domestic UK retrofit challenge: Barriers, incentives and current performance leading into the green deal

    Get PDF
    Copyright @ 2012 Elsevier - The official published version can be accessed from the link below.This paper reviews the thermal performance of the existing UK housing stock, the main fabric efficiency incentive schemes and the barriers to obtaining deep energy and CO2 savings throughout the stock. The UK faces a major challenge to improve the thermal performance of its existing housing stock. Millions of dwellings possess ‘hard-to-treat’ solid walls and have glazing which is not cost effective to improve. A range of fabric efficiency incentive schemes exist, but many do not target the full range of private and social housing. From now on, the Green Deal will be the UK's key energy efficiency policy. However, the scheme is forecasted to have low consumer appeal and low incentives for investors. Moreover, calculated Green Deal loan repayments will be reliant upon estimated energy savings, yet it is claimed that retrofit measures may only be half as effective as anticipated due to a lack of monitoring, poor quality installation and the increased use of heating following refurbishment. Looking to Germany, there has been success through the Passivhaus standard, but the UK currently lacks appropriate skills and cost effective components to replicate this approach. In addition, the embodied energy in retrofit products and materials threatens to counter operational savings.This study is funded by the EPSRC, Brunel University and Buro Happold Ltd

    National Evaluation of the Capacity Building Programme in English Local Government: Annex 4: Follow On Study of Progress in Seven Case Study Improvement Partnerships

    Get PDF
    This report is one of a series of outputs from the national evaluation of the Capacity Building Programme for local government in England (CBP), being undertaken by a team of researchers at the Policy Research Institute (PRI) at Leeds Metropolitan University and the Cities Research Unit at the University of West of England. This report summarises the findings from the second phase of fieldwork with regional and sub-regional Improvement Partnerships, established to facilitate capacity building and improvement activity in local authorities. The research underpinning this report was undertaken in seven case study Improvement Partnerships (see Section 2) in October and November 2006 and follows a similar – baseline – exercise undertaken during the same period during 2005. It thus both draws on the earlier research (see Section 3) and identifies evidence of progress and impact (see Section 10) since the baseline phase

    Removal processes for tributyltin during municipal wastewater treatment

    Get PDF
    This is the author's accepted manuscript. The final published article is available from the link below. Copyright @ 2013 Springer.The fate and behaviour of tributyltin (TBT) at two wastewater treatment works was examined. Both sites had two inlet streams, and each utilised high rate biological filters (biofilters) on one the streams, before treatment of the combined flows on trickling filters, with one having additional tertiary processes, installed to remove ammonia and solids. The study was designed to determine if these processes enhanced the removal of TBT. Degradation of TBT was observed in one of the biofilters, possibly as a result of temperature and hydraulic loading. At the treatment works with tertiary processes, the mass flux showed the overall removal of TBT was 68 %, predominantly due to removal with solids in the primary settlement processes. However, overall removal of 95 % was observed in the conventional trickling filter works with 94 % of this due to biodegradation in the trickling filter. The two works both removed TBT, but at different treatment stages and by different processes. Differences in the form (solubility) of TBT in the influent may have attributed to this, although further understanding of factors controlling degradation would allow for a more complete assessment of the potential of biological processes to remove hazardous compounds from wastewaters.United Utilities PL

    Non-Newtonian Mixed Thermo-Elastohydrodynamics of Hypoid Gear Pairs

    Get PDF
    Transmission efficiency is the main objective in the development of vehicular differential systems, comprising hypoid gear pairs. The overall aim is to contribute to improved vehicle fuel efficiency and thus levels of harmful emissions for modern desired eco-drive axles. Detailed predictive analysis plays an important role in this quest, particularly under realistic operating conditions, comprising high contact loads and shear rates. Under these conditions, the hypoid gear pairs are subject to mixed non-Newtonian thermo-elastohydrodynamic conditions, which is the approach undertaken in this paper. Such an approach for hypoid gear pair has not hitherto been reported in the literature

    The Effect of Microseparation on Corrosion Rates of Metal-on-Metal Total Hip Replacements

    Get PDF
    The poor performance of Metal-on-Metal (MoM) bearings has to date been blamed on “adverse loading” conditions. Studies have focused on the effect of cup inclination and microseparation on gravimetric wear rates and highlighted the importance of surgical technique when implanting such devices. Up to four fold increase in the wear rates of MoM bearings subjected to microseparation has been reported during the bedding-in period. The contribution of corrosive processes to overall material degradation during adverse loading has not previously been investigated. In the present study 28 mm HC CoCrMo alloy Total Hip Replacements were tested to 1 Mcycles under standard gait and severe microseparation conditions in an electrochemically instrumented hip simulator. An order of magnitude increase in material lost as a result of oxidation was noted (0.234 to 2.044 mm3/Mcycle) during microseparation. Corrosive degradation may therefore be a much more significant contribution to poor bearing performance under adverse loading than previously considered

    Tribocorrosion of hard-on-hard total hip replacements with metal and ceramic counterfaces under standard and adverse loading conditions

    Get PDF
    28 mm Metal-on-Metal (MoM) and Metal-on-Ceramic (MoC) Total Hip Replacements were articulated to 1 million cycles under both Standard Gait and Microseparation conditions. The hip simulator was fully instrumented with a three-electrode electrochemical cell to facilitate monitoring of corrosive degradation. The estimated volume loss from corrosion at the bearing surface was seen to increase by nearly an order of magnitude for both devices, representing as much as 17% of total degradation. Anodic current transients also displayed near order of magnitude increases in the peak current for both bearing couples. An adverse loading scenario could cause as much as an order of magnitude increase in the metallic ions released into the joint capsule as well as an increased volume of wear debris

    National Evaluation of the Capacity Building Programme in English Local Government: Evaluation of the National Programmes: Annex 2: Evaluation of the National Programmes

    Get PDF
    The report is one of a series of outputs from the national evaluation of the CBP, being undertaken by a team of researchers at the Policy Research Institute (PRI) at Leeds Metropolitan University and the Cities Research Unit at the University of West of England. The Capacity Building Programme for local government was launched in 2003 as a joint Department for Communities and Local Government (DCLG) / Local Government Association (LGA) initiative to support capacity building and improvement activities within local authorities in England. The evaluation of the Capacity Building Programme has been underway since late 2004. A scoping phase was conducted until May 2005, including a short evaluation of the Pilot Programmes. The main phase of the evaluation commenced in September 2005 and encompassed four main phases (see Section 1.3: p10)

    Trombe walls with nanoporous aerogel insulation applied to UK housing refurbishments

    Get PDF
    There is an opportunity to improve the efficiency of passive Trombe walls and active solar air collectors by replacing their conventional glass covers with lightweight polycarbonate panels filled with nanoporous aerogel insulation. This study investigates the thermal performance, energy savings, and financial payback period of passive Aerogel Trombe walls applied to the existing UK housing stock. Using parametric modeling, a series of design guidance tables have been generated, providing estimates of the energy savings and overheating risk associated with applying areas of Trombe wall to four different house types across the UK built to six notional construction standards. Calculated energy savings range from 183 kWh/m2/year for an 8 m2 system retrofitted to a solid walled detached house to 62 kWh/m2/year for a 32 m2 system retrofitted to a super insulated flat. Predicted energy savings from Trombe walls up to 24 m2 are found to exceed the energy savings from external insulation across all house types and constructions. Small areas of Trombe wall can provide a useful energy contribution without creating a significant overheating risk. If larger areas are to be installed, then detailed calculations would be recommended to assess and mitigate potential overheating issues.The EPSRC, Brunel University, and Buro Happold Lt
    corecore