1,195 research outputs found

    Design and Analysis of Novel Ge-GeTe PN Junction for Photovoltaics

    Get PDF
    The continuing rise in demand for energy places a similarly increasing demand to improve power production methods and efficiency. In regards to solar power generation, one major limiting factor with existing photovoltaic (PV) systems is the management of heat produced and photon interactions with the PV device. Typical devices operate within the 300-1000 nm range of the solar spectrum, greatly limiting the range of photons used for power generation. Furthermore, since infrared light

    Engineered surfaces to control secondary electron emission for multipactor suppression

    Get PDF
    A significant problem for space-based systems is multipactor - an avalanche of electrons caused by repeated secondary electron emission (SEE). The consequences of multipactor range from altering the operation of radio frequency (RF) devices to permanent device damage. Existing efforts to suppress multipactor rely heavily on limiting power levels below a multipactor threshold [1]. This research applies surface micromachining techniques to create porous surfaces to control the secondary electron yield (SEY) of a material for multipactor suppression. Surface characteristics of interest include pore aspect ratio and density. A discussion is provided on the advantage of using electroplating (vice etching) to create porous surfaces for studying the relationships between SEY and pore aspect ratio & density (i.e. porosity). Preventing multipactor through SEY reduction will allow power level restrictions to be eased, leading to more powerful and capable space-based systems

    The Sensitivity of the IceCube Neutrino Detector to Dark Matter Annihilating in Dwarf Galaxies

    Get PDF
    In this paper, we compare the relative sensitivities of gamma-ray and neutrino observations to the dark matter annihilation cross section in leptophilic models such as have been designed to explain PAMELA data. We investigate whether the high energy neutrino telescope IceCube will be competitive with current and upcoming searches by gamma-ray telescopes, such as the Atmospheric Cerenkov Telescopes (ACTs) (HESS, VERITAS and MAGIC), or the Fermi Gamma Ray Space Telescope, in detecting or constraining dark matter particles annihilating in dwarf spheroidal galaxies. We find that after ten years of observation of the most promising nearby dwarfs, IceCube will have sensitivity comparable to the current sensitivity of gamma-ray telescopes only for very heavy (m_X > 7 TeV) or relatively light (m_X < 200 GeV) dark matter particles which annihilate primarily to mu+mu-. If dark matter particles annihilate primarily to tau+tau-, IceCube will have superior sensitivity only for dark matter particle masses below the 200 GeV threshold of current ACTs. If dark matter annihilations proceed directly to neutrino-antineutrino pairs a substantial fraction of the time, IceCube will be competitive with gamma-ray telescopes for a much wider range of dark matter masses.Comment: 7 pages, 3 figures. v2: references added and minor revisions. v3: as published in PRD

    Measurement and Modeling of Infrared Nonlinear Absorption Coefficients and Laser-induced Damage Thresholds in Ge and GaSb

    Get PDF
    Using a simultaneous fitting technique to extract nonlinear absorption coefficients from data at two pulse widths, we measure two-photon and free-carrier absorption coefficients for Ge and GaSb at 2.05 and 2.5 μm for the first time, to our knowledge. Results agreed well with published theory. Single-shot damage thresholds were also measured at 2.5 μm and agreed well with modeled thresholds using experimentally determined parameters including nonlinear absorption coefficients and temperature dependent linear absorption. The damage threshold for a single-layer Al2O3 anti-reflective coating on Ge was 55% or 35% lower than the uncoated threshold for picosecond or nanosecond pulses, respectively

    Surface Feature Engineering through Nanosphere Lithography

    Get PDF
    How surface geometries can be selectively manipulated through nanosphere lithography (NSL) is discussed. Self-assembled monolayers and multilayers of nanospheres have been studied for decades and have been applied to lithography for almost as long. When compared to the most modern, state-of-the-art techniques, NSL offers comparable feature resolution with many advantages over competing technologies

    Searching for Dark Matter with Future Cosmic Positron Experiments

    Full text link
    Dark matter particles annihilating in the Galactic halo can provide a flux of positrons potentially observable in upcoming experiments, such as PAMELA and AMS-02. We discuss the spectral features which may be associated with dark matter annihilation in the positron spectrum and assess the prospects for observing such features in future experiments. Although we focus on some specific dark matter candidates, neutralinos and Kaluza-Klein states, we carry out our study in a model independent fashion. We also revisit the positron spectrum observed by HEAT.Comment: 19 pages, 33 figure

    Modeling Micro-Porous Surfaces for Secondary Electron Emission Control to Suppress Multipactor

    Get PDF
    This work seeks to understand how the topography of a surface can be engineered to control secondary electron emission (SEE) for multipactor suppression. Two unique, semi-empirical models for the secondary electron yield (SEY) of a micro-porous surface are derived and compared. The first model is based on a two-dimensional (2D) pore geometry. The second model is based on a three-dimensional (3D) pore geometry. The SEY of both models is shown to depend on two categories of surface parameters: chemistry and topography. An important parameter in these models is the probability of electron emissions to escape the surface pores. This probability is shown by both models to depend exclusively on the aspect ratio of the pore (the ratio of the pore height to the pore diameter). The increased accuracy of the 3D model (compared to the 2D model) results in lower electron escape probabilities with the greatest reductions occurring for aspect ratios less than two. In order to validate these models, a variety of micro-porous gold surfaces were designed and fabricated using photolithography and electroplating processes. The use of an additive metal-deposition process (instead of the more commonly used subtractive metal-etch process) provided geometrically ideal pores which were necessary to accurately assess the 2D and 3D models. Comparison of the experimentally measured SEY data with model predictions from both the 2D and 3D models illustrates the improved accuracy of the 3D model. For a micro-porous gold surface consisting of pores with aspect ratios of two and a 50% pore density, the 3D model predicts that the maximum total SEY will be one. This provides optimal engineered surface design objectives to pursue for multipactor suppression using gold surfaces

    New Measurement of the Cosmic-Ray Positron Fraction from 5 to 15 GeV

    Get PDF
    We present a new measurement of the cosmic-ray positron fraction at energies between 5 and 15 GeV with the balloon-borne HEAT-pbar instrument in the spring of 2000. The data presented here are compatible with our previous measurements, obtained with a different instrument. The combined data from the three HEAT flights indicate a small positron flux of non-standard origin above 5 GeV. We compare the new measurement with earlier data obtained with the HEAT-e+- instrument, during the opposite epoch of the solar cycle, and conclude that our measurements do not support predictions of charge sign dependent solar modulation of the positron abundance at 5 GeV.Comment: accepted for publication in PR

    Modeling Micro-porous Surfaces for Secondary Electron Emission Control to Suppress Multipactor

    Get PDF
    This work seeks to understand how the topography of a surface can be engineered to control secondary electron emission (SEE) for multipactor suppression. Two unique, semi-empirical models for the secondary electron yield (SEY) of a micro-porous surface are derived and compared. The first model is based on a two-dimensional (2D) pore geometry. The second model is based on a three-dimensional (3D) pore geometry. The SEY of both models is shown to depend on two categories of surface parameters: chemistry and topography. An important parameter in these models is the probability of electron emissions to escape the surface pores. This probability is shown by both models to depend exclusively on the aspect ratio of the pore (the ratio of the pore height to the pore diameter). The increased accuracy of the 3D model (compared to the 2D model) results in lower electron escape probabilities with the greatest reductions occurring for aspect ratios less than two. In order to validate these models, a variety of micro-porous gold surfaces were designed and fabricated using photolithography and electroplating processes. The use of an additive metal-deposition process (instead of the more commonly used subtractive metal-etch process) provided geometrically ideal pores which were necessary to accurately assess the 2D and 3D models. Comparison of the experimentally measured SEY data with model predictions from both the 2D and 3D models illustrates the improved accuracy of the 3D model. For a micro-porous gold surface consisting of pores with aspect ratios of two and a 50% pore density, the 3D model predicts that the maximum total SEY will be one. This provides optimal engineered surface design objectives to pursue for multipactor suppression using gold surfaces. © 2017 Author(s)

    Indirect Detection of Kaluza-Klein Dark Matter from Latticized Universal Dimensions

    Full text link
    We consider Kaluza-Klein dark matter from latticized universal dimensions. We motivate and investigate two different lattice models, where the models differ in the choice of boundary conditions. The models reproduce relevant features of the continuum model for Kaluza-Klein dark matter. For the model with simple boundary conditions, this is the case even for a model with only a few lattice sites. We study the effects of the latticization on the differential flux of positrons from Kaluza-Klein dark matter annihilation in the galactic halo. We find that for different choices of the compactification radius, the differential positron flux rapidly converges to the continuum model results as a function of the number of lattice sites. In addition, we consider the prospects for upcoming space-based experiments such as PAMELA and AMS-02 to probe the latticization effect.Comment: 25 pages, 9 figures, LaTeX. Final version published in JCA
    • …
    corecore