23 research outputs found
The ENTSO-E Transparency Platform. An assessment of Europe’s most ambitious electricity data platform
Applied power system research is data intensive, often requiring hour-by-hour data on electricity consumption and generation as well as detailed information about technical and cost parameters of power stations. The European Union obliges firms to publish much of this information on a common website, the “ENTSO-E Transparency Platform” operated by the association of transmission system operators. It is possibly the most ambitious platform for power system data globally. However, anecdotal evidence from users indicates significant shortcomings regarding data quality and usability. This paper provides an introduction to and an assessment of the Transparency Platform, helping researchers to use it more efficiently and to judge data quality more rigorously
Real-time intravital multiphoton microscopy to visualize focused ultrasound and microbubble treatments to increase blood-brain barrier permeability
The blood-brain barrier (BBB) is a key challenge for the successful delivery of drugs to the brain. Ultrasound exposure in the presence of microbubbles has emerged as an effective method to transiently and locally increase the permeability of the BBB, facilitating para- and transcellular transport of drugs across the BBB. Imaging the vasculature during ultrasound-microbubble treatment will provide valuable and novel insights on the mechanisms and dynamics of ultrasound-microbubble treatments in the brain.
Here, we present an experimental procedure for intravital multiphoton microscopy using a cranial window aligned with a ring transducer and a 20x objective lens. This set-up enables high spatial and temporal resolution imaging of the brain during ultrasound-microbubble treatments. Optical access to the brain is obtained via an open-skull cranial window. Briefly, a 3-4 mm diameter piece of the skull is removed, and the exposed area of the brain is sealed with a glass coverslip. A 0.82 MHz ring transducer, which is attached to a second glass coverslip, is mounted on top. Agarose (1% w/v) is used between the coverslip of the transducer and the coverslip covering the cranial window to prevent air bubbles, which impede ultrasound propagation. When sterile surgery procedures and anti-inflammatory measures are taken, ultrasound-microbubble treatments and imaging sessions can be performed repeatedly over several weeks. Fluorescent dextran conjugates are injected intravenously to visualize the vasculature and quantify ultrasound-microbubble induced effects (e.g., leakage kinetics, vascular changes). This paper describes the cranial window placement, ring transducer placement, imaging procedure, common troubleshooting steps, as well as advantages and limitations of the method.publishedVersio
Ultrafast Microscopy Imaging of Acoustic Cluster Therapy Bubbles: Activation and Oscillation
Acoustic Cluster Therapy (ACT®) is a platform for improving drug delivery and has had promising pre-clinical results. A clinical trial is ongoing. ACT® is based on microclusters of microbubbles–microdroplets that, when sonicated, form a large ACT® bubble. The aim of this study was to obtain new knowledge on the dynamic formation and oscillations of ACT® bubbles by ultrafast optical imaging in a microchannel. The high-speed recordings revealed the microbubble–microdroplet fusion, and the gas in the microbubble acted as a vaporization seed for the microdroplet. Subsequently, the bubble grew by gas diffusion from the surrounding medium and became a large ACT® bubble with a diameter of 5–50 μm. A second ultrasound exposure at lower frequency caused the ACT® bubble to oscillate. The recorded oscillations were compared with simulations using the modified Rayleigh–Plesset equation. A term accounting for the physical boundary imposed by the microchannel wall was included. The recorded oscillation amplitudes were approximately 1–2 µm, hence similar to oscillations of smaller contrast agent microbubbles. These findings, together with our previously reported promising pre-clinical therapeutic results, suggest that these oscillations covering a large part of the vessel wall because of the large bubble volume can substantially improve therapeutic outcome.publishedVersio
Open Power System Data - Frictionless data for electricity system modelling
The quality of electricity system modelling heavily depends on the input data
used. Although a lot of data is publicly available, it is often dispersed,
tedious to process and partly contains errors. We argue that a central
provision of input data for modelling has the character of a public good: it
reduces overall societal costs for quantitative energy research as redundant
work is avoided, and it improves transparency and reproducibility in
electricity system modelling. This paper describes the Open Power System Data
platform that aims at realising the efficiency and quality gains of centralised
data provision by collecting, checking, processing, aggregating, documenting
and publishing data required by most modellers. We conclude that the platform
can provide substantial benefits to energy system analysis by raising
efficiency of data pre-processing, providing a method for making data
pre-processing for energy system modelling traceable, flexible and reproducible
and improving the quality of original data published by data providers.Comment: This is the postprint version of the articl
Real-time intravital multiphoton microscopy to visualize focused ultrasound and microbubble treatments to increase blood-brain barrier permeability
The blood-brain barrier (BBB) is a key challenge for the successful delivery of drugs to the brain. Ultrasound exposure in the presence of microbubbles has emerged as an effective method to transiently and locally increase the permeability of the BBB, facilitating para- and transcellular transport of drugs across the BBB. Imaging the vasculature during ultrasound-microbubble treatment will provide valuable and novel insights on the mechanisms and dynamics of ultrasound-microbubble treatments in the brain.
Here, we present an experimental procedure for intravital multiphoton microscopy using a cranial window aligned with a ring transducer and a 20x objective lens. This set-up enables high spatial and temporal resolution imaging of the brain during ultrasound-microbubble treatments. Optical access to the brain is obtained via an open-skull cranial window. Briefly, a 3-4 mm diameter piece of the skull is removed, and the exposed area of the brain is sealed with a glass coverslip. A 0.82 MHz ring transducer, which is attached to a second glass coverslip, is mounted on top. Agarose (1% w/v) is used between the coverslip of the transducer and the coverslip covering the cranial window to prevent air bubbles, which impede ultrasound propagation. When sterile surgery procedures and anti-inflammatory measures are taken, ultrasound-microbubble treatments and imaging sessions can be performed repeatedly over several weeks. Fluorescent dextran conjugates are injected intravenously to visualize the vasculature and quantify ultrasound-microbubble induced effects (e.g., leakage kinetics, vascular changes). This paper describes the cranial window placement, ring transducer placement, imaging procedure, common troubleshooting steps, as well as advantages and limitations of the method
Ultrafast Microscopy Imaging of Acoustic Cluster Therapy Bubbles: Activation and Oscillation
Acoustic Cluster Therapy (ACT®) is a platform for improving drug delivery and has had promising pre-clinical results. A clinical trial is ongoing. ACT® is based on microclusters of microbubbles–microdroplets that, when sonicated, form a large ACT® bubble. The aim of this study was to obtain new knowledge on the dynamic formation and oscillations of ACT® bubbles by ultrafast optical imaging in a microchannel. The high-speed recordings revealed the microbubble–microdroplet fusion, and the gas in the microbubble acted as a vaporization seed for the microdroplet. Subsequently, the bubble grew by gas diffusion from the surrounding medium and became a large ACT® bubble with a diameter of 5–50 μm. A second ultrasound exposure at lower frequency caused the ACT® bubble to oscillate. The recorded oscillations were compared with simulations using the modified Rayleigh–Plesset equation. A term accounting for the physical boundary imposed by the microchannel wall was included. The recorded oscillation amplitudes were approximately 1–2 µm, hence similar to oscillations of smaller contrast agent microbubbles. These findings, together with our previously reported promising pre-clinical therapeutic results, suggest that these oscillations covering a large part of the vessel wall because of the large bubble volume can substantially improve therapeutic outcome
Focused ultrasound and microbubble treatment increases delivery of transferrin receptor-targeting liposomes to the brain
The blood-brain barrier (BBB) is a major obstacle to treating several brain disorders. Focused ultrasound (FUS) in combination with intravascular microbubbles increases BBB permeability by opening tight junctions, creating endothelial cell openings, improving endocytosis and increasing transcytosis. Here we investigated whether combining FUS and microbubbles with transferrin receptor-targeting liposomes would result in enhanced delivery to the brain of post-natal rats compared with liposomes lacking the BBB-targeting moiety. For all animals, increased BBB permeability was observed after FUS treatment. A 40% increase in accumulation of transferrin receptor-targeting liposomes was observed in the FUS-treated hemisphere, whereas the isotype immunoglobulin G liposomes showed no increased accumulation. Confocal laser scanning microscopy of brain sections revealed that both types of liposomes were mainly observed in endothelial cells in the FUS-treated hemisphere. The results demonstrate that FUS and microbubble treatment combined with BBB-targeting liposomes could be a promising approach to enhance drug delivery to the brain. (E-mail: marieke.olsman@ntnu. no
Ultrafast Microscopy Imaging of Acoustic Cluster Therapy Bubbles: Activation and Oscillation
Acoustic Cluster Therapy (ACT®) is a platform for improving drug delivery and has had promising pre-clinical results. A clinical trial is ongoing. ACT® is based on microclusters of microbubbles–microdroplets that, when sonicated, form a large ACT® bubble. The aim of this study was to obtain new knowledge on the dynamic formation and oscillations of ACT® bubbles by ultrafast optical imaging in a microchannel. The high-speed recordings revealed the microbubble–microdroplet fusion, and the gas in the microbubble acted as a vaporization seed for the microdroplet. Subsequently, the bubble grew by gas diffusion from the surrounding medium and became a large ACT® bubble with a diameter of 5–50 μm. A second ultrasound exposure at lower frequency caused the ACT® bubble to oscillate. The recorded oscillations were compared with simulations using the modified Rayleigh–Plesset equation. A term accounting for the physical boundary imposed by the microchannel wall was included. The recorded oscillation amplitudes were approximately 1–2 µm, hence similar to oscillations of smaller contrast agent microbubbles. These findings, together with our previously reported promising pre-clinical therapeutic results, suggest that these oscillations covering a large part of the vessel wall because of the large bubble volume can substantially improve therapeutic outcome