48 research outputs found
Visco-Node-Pore Sensing: A Microfluidic Rheology Platform to Characterize Viscoelastic Properties of Epithelial Cells.
Viscoelastic properties of cells provide valuable information regarding biological or clinically relevant cellular characteristics. Here, we introduce a new, electronic-based, microfluidic platform-visco-node-pore sensing (visco-NPS)-which quantifies cellular viscoelastic properties under periodic deformation. We measure the storage (G) and loss (G″) moduli (i.e., elasticity and viscosity, respectively) of cells. By applying a wide range of deformation frequencies, our platform quantifies the frequency dependence of viscoelastic properties. G and G″ measurements show that the viscoelastic properties of malignant breast epithelial cells (MCF-7) are distinctly different from those of non-malignant breast epithelial cells (MCF-10A). With its sensitivity, visco-NPS can dissect the individual contributions of different cytoskeletal components to whole-cell mechanical properties. Moreover, visco-NPS can quantify the mechanical transitions of cells as they traverse the cell cycle or are initiated into an epithelial-mesenchymal transition. Visco-NPS identifies viscoelastic characteristics of cell populations, providing a biophysical understanding of cellular behavior and a potential for clinical applications
Recommended from our members
Probing Interactions at the Nanoscale: Sensing Protein Molecules
Introduction We have developed a high-frequency electronic biosensor of parallel-plate geometry that is embedded within a microfluidic device. This novel biosensor allows us to perform dielectric spectroscopy on a variety of biological samples—from cells to molecules—in solution. Because it is purely electronic, the sensor allows for rapid characterization with no sample preparation or chemical alteration. In addition, it is capable of probing length scales from millimeters to microns over a frequency range 50 MHz to 40 GHz, and sample volumes as small as picoliters [1,2]. Our high-frequency biosensor has evolved from previous device designs based on a coplanar waveguide (CPW) geometry [2]. For our current device, we employ microfluidic tectonics (µFT) [3] to embed two microstrip conductors within a microfluidic channel. The electronic coupling between the two conductors is greater than in our previous CPW design and more importantly, leads to an enhanced sensitivity. Our utilization of µFT allows us to incorporate easily this high-frequency electronic biosensor with a variety of lab-on-a-chip architectures. Device Description Figure 1 is a schematic of our high-frequency electronic biosensor. We fabricate this sensor by first depositing a 500 Å seed layer of gold onto two glass microscope slides. We then use photolithography to pattern the gold that is subsequently electroplated to a thickness of 4-6 µm. After reactive-ion etching the photoresist and removing the unplated gold with a standard iodine-based gold etchant, we align the two slides under a microscope such that the microstrip conductors overlap one another in a parallel-plate geometry (80 µm x 500 µm). We control the separation between the microstrip conductors using gold foil spacers 3–25 µm thick. The foil additionally ensures coupling between the grounds on each slide. Following alignment, we employ µFT to bond the two glass slides together and to create a microfluidic channel running perpendicular to the microstrip conductors (see Figure 1). We complete the device by inserting 0.02” ID vinyl tubing through predrilled input and output holes of the device [3]. All of our devices are designed to have a 50 Ω matched impedance and minimal insertion loss for 0.05 – 40 GHz. With these characteristics, we expect a sensitivity of 0.05 dB. Results By accessing frequencies > 20 GHz with our device, we can probe unique low-frequency vibrational or rotational modes of bio-macromolecules, since at these frequencies the counterions have fully relaxed, the dipole moment of water is rapidly decreasing, and the macroscopic distortions of macromolecules become important and are reflected in the obtained spectra. As a first demonstration, we have measured PCR products. We are able to distinguish between non-reacted primers for PCR amplification and reacted PCR products (24 amplification cycles). Figure 2 shows representative spectra of the two different DNA solutions obtained from a single device and scaled to DI water. We have obtained similar spectral features from additional devices and are currently developing a quantitative model to explain our results. This initial demonstration of molecular differentiation using a high-frequency electronic biosensor shows the great promise of electronic biosensing
Personalized Exposure Assessment: Promising Approaches for Human Environmental Health Research
New technologies and methods for assessing human exposure to chemicals, dietary and lifestyle factors, infectious agents, and other stressors provide an opportunity to extend the range of human health investigations and advance our understanding of the relationship between environmental exposure and disease. An ad hoc Committee on Environmental Exposure Technology Development was convened to identify new technologies and methods for deriving personalized exposure measurements for application to environmental health studies. The committee identified a “toolbox” of methods for measuring external (environmental) and internal (biologic) exposure and assessing human behaviors that influence the likelihood of exposure to environmental agents. The methods use environmental sensors, geographic information systems, biologic sensors, toxicogenomics, and body burden (biologic) measurements. We discuss each of the methods in relation to current use in human health research; specific gaps in the development, validation, and application of the methods are highlighted. We also present a conceptual framework for moving these technologies into use and acceptance by the scientific community. The framework focuses on understanding complex human diseases using an integrated approach to exposure assessment to define particular exposure–disease relationships and the interaction of genetic and environmental factors in disease occurrence. Improved methods for exposure assessment will result in better means of monitoring and targeting intervention and prevention programs
Tuberculosis in Pediatric Antiretroviral Therapy Programs in Low- and Middle-Income Countries: Diagnosis and Screening Practices
Background The global burden of childhood tuberculosis (TB) is estimated to be 0.5 million new cases per year. Human immunodeficiency virus (HIV)-infected children are at high risk for TB. Diagnosis of TB in HIV-infected children remains a major challenge. Methods We describe TB diagnosis and screening practices of pediatric antiretroviral treatment (ART) programs in Africa, Asia, the Caribbean, and Central and South America. We used web-based questionnaires to collect data on ART programs and patients seen from March to July 2012. Forty-three ART programs treating children in 23 countries participated in the study. Results Sputum microscopy and chest Radiograph were available at all programs, mycobacterial culture in 40 (93%) sites, gastric aspiration in 27 (63%), induced sputum in 23 (54%), and Xpert MTB/RIF in 16 (37%) sites. Screening practices to exclude active TB before starting ART included contact history in 41 sites (84%), symptom screening in 38 (88%), and chest Radiograph in 34 sites (79%). The use of diagnostic tools was examined among 146 children diagnosed with TB during the study period. Chest Radiograph was used in 125 (86%) children, sputum microscopy in 76 (52%), induced sputum microscopy in 38 (26%), gastric aspirate microscopy in 35 (24%), culture in 25 (17%), and Xpert MTB/RIF in 11 (8%) children. Conclusions Induced sputum and Xpert MTB/RIF were infrequently available to diagnose childhood TB, and screening was largely based on symptom identification. There is an urgent need to improve the capacity of ART programs in low- and middle-income countries to exclude and diagnose TB in HIV-infected childre
Graphic loans: East Asia and beyond
The national languages of East Asia (Chinese, Japanese, Korean and Vietnamese) have made extensive use of a type of linguistic borrowing sometimes referred to as a 'graphic loan'. Such loans have no place in the conventional classification of loans based on Haugen (1950) or Weinreich (1953), and research on loan word theory and phonology generally overlooks them. The classic East Asian phenomenon is discussed and a framework is proposed to describe its mechanism. It is argued that graphic loans are more than just 'spelling pronunciations', because they are a systematic and widespread process, independent of but not inferior to phonological borrowing. The framework is then expanded to cover a range of other cases of borrowing between languages to show that graphic loans are not a uniquely East Asian phenomenon, and therefore need to be considered as a major category of loan
The promise of single-cell mechanophenotyping for clinical applications.
Cancer is the second leading cause of death worldwide. Despite the immense research focused in this area, one is still not able to predict disease trajectory. To overcome shortcomings in cancer disease study and monitoring, we describe an exciting research direction: cellular mechanophenotyping. Cancer cells must overcome many challenges involving external forces from neighboring cells, the extracellular matrix, and the vasculature to survive and thrive. Identifying and understanding their mechanical behavior in response to these forces would advance our understanding of cancer. Moreover, used alongside traditional methods of immunostaining and genetic analysis, mechanophenotyping could provide a comprehensive view of a heterogeneous tumor. In this perspective, we focus on new technologies that enable single-cell mechanophenotyping. Single-cell analysis is vitally important, as mechanical stimuli from the environment may obscure the inherent mechanical properties of a cell that can change over time. Moreover, bulk studies mask the heterogeneity in mechanical properties of single cells, especially those rare subpopulations that aggressively lead to cancer progression or therapeutic resistance. The technologies on which we focus include atomic force microscopy, suspended microchannel resonators, hydrodynamic and optical stretching, and mechano-node pore sensing. These technologies are poised to contribute to our understanding of disease progression as well as present clinical opportunities
Recommended from our members
Metal-pad-enhanced resistive pulse sensor reveals complex-valued Braess paradox.
A resistive pulse sensor measures the electrical impedance of an electrolyte-filled channel as particles flow through it. Ordinarily, the presence of a nonconductive particle increases the impedance of the channel. Here we report a surprising experimental result in which a microfluidic resistive pulse sensor experiences the opposite effect: The presence of a nonconductive particle decreases the channel impedance. We explain the counterintuitive phenomenon by relating to the Braess paradox from traffic network theory, and we call it the complex-valued Braess paradox (CVBP). We develop theoretical models to study the CVBP and corroborate the experimental data using finite element simulations and lumped-element circuit modeling. We then discuss implications and potential applications of the CVBP in resistive pulse sensing and beyond
Recommended from our members
Node-Pore Sensing for Characterizing Cells and Extracellular Vesicles.
Node-Pore Sensing, NPS, is an extremely versatile and powerful technique for the analysis of cells and the detection of extracellular vesicles (EVs). NPS involves measuring the modulated current pulse caused by a cell transiting a microfluidic channel that has been segmented by a series of inserted nodes. As the current pulse reflects the number of nodes and segments of the channel, NPS can achieve exquisite sensitivity. Thus, when used as a Coulter counter, NPS can measure the sub-micron size increase of antibody-coated colloids to which EVs are specifically bound. By simply inserting between two nodes a contraction channel through which cells can squeeze, one can mechanically phenotype cells. We discuss the details of performing these two NPS applications
DNA-Directed Patterning for Versatile Validation and Characterization of a Lipid-Based Nanoparticle Model of SARS-CoV-2
Lipid-based nanoparticles
have risen to the forefront of the COVID-19 pandemic—from encapsulation of
vaccine components to modeling the virus, itself. Their rapid development in
the face of the volatile nature of the pandemic requires high-throughput,
highly flexible methods for characterization. DNA-directed patterning is a
versatile method to immobilize and segregate lipid-based nanoparticles for subsequent
analysis. DNA-directed patterning selectively conjugates oligonucleotides onto
a glass substrate and then hybridizes them to complementary oligonucleotides
tagged to the liposomes, thereby patterning them with great control and
precision. The power of this method is demonstrated by characterizing a novel
recapitulative lipid-based nanoparticle model of SARS-CoV-2 —S-liposomes— which
present the SARS-CoV-2 spike (S) protein on their surfaces. Patterning of a
mixture of S-liposomes and liposomes that display the tetraspanin CD63 into discrete
regions of a substrate is used to show that ACE2 specifically binds to
S-liposomes. Importantly, DNA-directed patterning of S-liposomes is used to
verify the performance of a commercially available neutralizing antibody
against the S protein. Ultimately, the introduction of S-liposomes to
ACE2-expressing cells demonstrates the biological relevance of DNA-directed
patterning. Overall, DNA-directed patterning enables a wide variety of custom
assays for the characterization of any lipid-based nanoparticle