7 research outputs found

    Collateral Status on Baseline Computed Tomographic Angiography and Intra-Arterial Treatment Effect in Patients With Proximal Anterior Circulation Stroke

    Get PDF
    Item does not contain fulltextBACKGROUND AND PURPOSE: Recent randomized trials have proven the benefit of intra-arterial treatment (IAT) with retrievable stents in acute ischemic stroke. Patients with poor or absent collaterals (preexistent anastomoses to maintain blood flow in case of a primary vessel occlusion) may gain less clinical benefit from IAT. In this post hoc analysis, we aimed to assess whether the effect of IAT was modified by collateral status on baseline computed tomographic angiography in the Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke in the Netherlands (MR CLEAN). METHODS: MR CLEAN was a multicenter, randomized trial of IAT versus no IAT. Primary outcome was the modified Rankin Scale at 90 days. The primary effect parameter was the adjusted common odds ratio for a shift in direction of a better outcome on the modified Rankin Scale. Collaterals were graded from 0 (absent) to 3 (good). We used multivariable ordinal logistic regression analysis with interaction terms to estimate treatment effect modification by collateral status. RESULTS: We found a significant modification of treatment effect by collaterals (P=0.038). The strongest benefit (adjusted common odds ratio 3.2 [95% confidence intervals 1.7-6.2]) was found in patients with good collaterals (grade 3). The adjusted common odds ratio was 1.6 [95% confidence intervals 1.0-2.7] for moderate collaterals (grade 2), 1.2 [95% confidence intervals 0.7-2.3] for poor collaterals (grade 1), and 1.0 [95% confidence intervals 0.1-8.7] for patients with absent collaterals (grade 0). CONCLUSIONS: In MR CLEAN, baseline computed tomographic angiography collateral status modified the treatment effect. The benefit of IAT was greatest in patients with good collaterals on baseline computed tomographic angiography. Treatment benefit appeared less and may be absent in patients with absent or poor collaterals. CLINICAL TRIAL REGISTRATION: URL: http://www.trialregister.nl and http://www.controlled-trials.com. Unique identifier: (NTR)1804 and ISRCTN10888758, respectively

    Supplementary Material for: The Prognostic Value of CT Angiography and CT Perfusion in Acute Ischemic Stroke

    No full text
    <br><strong><em>Background:</em></strong> CT angiography (CTA) and CT perfusion (CTP) are important diagnostic tools in acute ischemic stroke. We investigated the prognostic value of CTA and CTP for clinical outcome and determined whether they have additional prognostic value over patient characteristics and non-contrast CT (NCCT). <b><i>Methods:</i></b> We included 1,374 patients with suspected acute ischemic stroke in the prospective multicenter Dutch acute stroke study. Sixty percent of the cohort was used for deriving the predictors and the remaining 40% for validating them. We calculated the predictive values of CTA and CTP predictors for poor clinical outcome (modified Rankin Scale score 3-6). Associations between CTA and CTP predictors and poor clinical outcome were assessed with odds ratios (OR). Multivariable logistic regression models were developed based on patient characteristics and NCCT predictors, and subsequently CTA and CTP predictors were added. The increase in area under the curve (AUC) value was determined to assess the additional prognostic value of CTA and CTP. Model validation was performed by assessing discrimination and calibration. <b><i>Results:</i></b> Poor outcome occurred in 501 patients (36.5%). Each of the evaluated CTA measures strongly predicted outcome in univariable analyses: the positive predictive value (PPV) was 59% for Alberta Stroke Program Early CT Score (ASPECTS) ≤7 on CTA source images (OR 3.3; 95% CI 2.3-4.8), 63% for presence of a proximal intracranial occlusion (OR 5.1; 95% CI 3.7-7.1), 66% for poor leptomeningeal collaterals (OR 4.3; 95% CI 2.8-6.6), and 58% for a >70% carotid or vertebrobasilar stenosis/occlusion (OR 3.2; 95% CI 2.2-4.6). The same applied to the CTP measures, as the PPVs were 65% for ASPECTS ≤7 on cerebral blood volume maps (OR 5.1; 95% CI 3.7-7.2) and 53% for ASPECTS ≤7 on mean transit time maps (OR 3.9; 95% CI 2.9-5.3). The prognostic model based on patient characteristics and NCCT measures was highly predictive for poor clinical outcome (AUC 0.84; 95% CI 0.81-0.86). Adding CTA and CTP predictors to this model did not improve the predictive value (AUC 0.85; 95% CI 0.83-0.88). In the validation cohort, the AUC values were 0.78 (95% CI 0.73-0.82) and 0.79 (95% CI 0.75-0.83), respectively. Calibration of the models was satisfactory. <b><i>Conclusions:</i></b> In patients with suspected acute ischemic stroke, admission CTA and CTP parameters are strong predictors of poor outcome and can be used to predict long-term clinical outcome. In multivariable prediction models, however, their additional prognostic value over patient characteristics and NCCT is limited in an unselected stroke population

    Improvements in Endovascular Treatment for Acute Ischemic Stroke:A Longitudinal Study in the MR CLEAN Registry

    Get PDF
    BACKGROUND: We evaluated data from all patients in the Netherlands who underwent endovascular treatment for acute ischemic stroke in the past 3.5 years, to identify nationwide trends in time to treatment and procedural success, and assess their effect on clinical outcomes. METHODS: We included patients with proximal occlusions of the anterior circulation from the second and first cohorts of the MR CLEAN (Multicenter Randomized Clinical trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) Registry (March 2014 to June 2016; June 2016 to November 2017, respectively). We compared workflow times and rates of successful reperfusion (defined as an extended thrombolysis in cerebral infarction score of 2B-3) between cohorts and chronological quartiles (all included patients stratified in chronological quartiles of intervention dates to create equally sized groups over the study period). Multivariable ordinal logistic regression was used to assess differences in the primary outcome (ordinal modified Rankin Scale at 90 days). RESULTS: Baseline characteristics were similar between cohorts (second cohort n=1692, first cohort n=1488) except for higher age, poorer collaterals, and less signs of early ischemia on computed tomography in the second cohort. Time from stroke onset to groin puncture and reperfusion were shorter in the second cohort (median 185 versus 210 minutes; P<0.001 and 236 versus 270 minutes; P<0.001, respectively). Successful reperfusion was achieved more often in the second than in the first cohort (72% versus 66%; P<0.001). Functional outcome significantly improved (adjusted common odds ratio 1.23 [95% CI, 1.07-1.40]). This effect was attenuated by adjustment for time from onset to reperfusion (adjusted common odds ratio, 1.12 [95% CI, 0.98-1.28]) and successful reperfusion (adjusted common odds ratio, 1.13 [95% CI, 0.99-1.30]). Outcomes were consistent in the analysis per chronological quartile. CONCLUSIONS: Clinical outcomes after endovascular treatment for acute ischemic stroke in routine clinical practice have improved over the past years, likely resulting from improved workflow times and higher successful reperfusion rates

    Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

    No full text
    Background: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment. Methods: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio >1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes. Results: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04). Conclusions: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome

    Prognostic Value of Thrombus Volume and Interaction With First-Line Endovascular Treatment Device Choice

    Get PDF
    BACKGROUND: A larger thrombus in patients with acute ischemic stroke might result in more complex endovascular treatment procedures, resulting in poorer patient outcomes. Current evidence on thrombus volume and length related to procedural and functional outcomes remains contradicting. This study aimed to assess the prognostic value of thrombus volume and thrombus length and whether this relationship differs between first-line stent retrievers and aspiration devices for endovascular treatment.METHODS: In this multicenter retrospective cohort study, 670 of 3279 patients from the MR CLEAN Registry (Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands) for endovascularly treated large vessel occlusions were included. Thrombus volume (0.1 mL) and length (0.1 mm) based on manual segmentations and measurements were related to reperfusion grade (expanded Treatment in Cerebral Infarction score) after endovascular treatment, the number of retrieval attempts, symptomatic intracranial hemorrhage, and a shift for functional outcome at 90 days measured with the reverted ordinal modified Rankin Scale (odds ratio &gt;1 implies a favorable outcome). Univariable and multivariable linear and logistic regression were used to report common odds ratios (cORs)/adjusted cOR and regression coefficients (B/aB) with 95% CIs. Furthermore, a multiplicative interaction term was used to analyze the relationship between first-line device choice, stent retrievers versus aspiration device, thrombus volume, and outcomes.RESULTS: Thrombus volume was associated with functional outcome (adjusted cOR, 0.83 [95% CI, 0.71-0.97]) and number of retrieval attempts (aB, 0.16 [95% CI, 0.16-0.28]) but not with the other outcome measures. Thrombus length was only associated with functional independence (adjusted cOR, 0.45 [95% CI, 0.24-0.85]). Patients with more voluminous thrombi had worse functional outcomes if endovascular treatment was based on first-line stent retrievers (interaction cOR, 0.67 [95% CI, 0.50-0.89]; P=0.005; adjusted cOR, 0.74 [95% CI, 0.55-1.0]; P=0.04). CONCLUSIONS: In this study, patients with a more voluminous thrombus required more endovascular thrombus retrieval attempts and had a worse functional outcome. Patients with a lengthier thrombus were less likely to achieve functional independence at 90 days. For more voluminous thrombi, first-line stent retrieval compared with first-line aspiration might be associated with worse functional outcome.</p
    corecore