10 research outputs found

    The ‘ins and outs’ of colonoscopy at Wits Donald Gordon Medical Centre, South Africa: A practice audit of the outpatient endoscopy unit

    Get PDF
    Background. In South Africa, there are no national guidelines for the conduct or quality assessment of colonoscopy, the gold standard for investigation and diagnosis of bowel pathology.Objectives. To describe the clinical profile of patients and evaluate the practice of colonoscopy using procedural quality indicators at the Wits Donald Gordon Medical Centre (WDGMC) outpatient endoscopy unit (OEU).Methods. We conducted a prospective, clinical practice audit of colonoscopies performed on adults (≥18 years of age). A total of 1 643 patients were included in the study and variables that were collected enabled the assessment of adequacy of bowel preparation, length of withdrawal time and calculation of caecal intubation rate (CIR), polyp detection rate (PDR) and adenoma detection rate (ADR). We stratified PDR and ADR by sex, age, population group, withdrawal time and bowel preparation. CIR, PDR and ADR estimates were compared between patient groups by the χ2 test; Fisher’s exact test was used for 2 × 2 tables. A p-value <0.05 was used. Benchmark recommendations by the American Society for Gastrointestinal Endoscopy (ASGE)/American College of Gastroenterology (ACG) Task Force on Colorectal Cancer (CRC) were used in this audit to assess individual endoscopist performance and that of the endoscopy unit as a whole.Results. The mean age of patients was 55.7 (standard deviation (SD) 14.4; range 18 - 91) years, ~60% were female, and the majority (75.5%) were white. Of the outpatients, 77.6% had adequate bowel preparation (ASGE/ACG benchmark ≥85%). The CIR was 97.0% overall, and screening colonoscopy was 96.3% (ASGE/ACG benchmark ≥90% overall and ≥95% for screening colonoscopies). The median withdrawal time for negative-result screening colonoscopies was 5.7 minutes (interquartile range (IQR) 4.2 - 9.3; range 1.1 - 20.6) (ASGE/ACG benchmark ≥ 6minutes), and PDR and ADR were 27.6% and 15.6%, respectively (ASGE/ACG benchmark ADR ≥25%). We demonstrated a 23.7% increase in PDR and 14.1% increase in ADR between scopes that had mean withdrawal times of ≥6 minutes and <6 minutes, respectively. Although the number of black Africans in the study was relatively small, our results showed that they have similar ADRs and PDRs to the white population group, contradicting popular belief.Conclusions. The WDGMC OEU performed reasonably well against the international guidelines, despite some inadequacy in bowel preparation and lower than recommended median withdrawal times on negative-result colonoscopy. Annual auditing of clinical practice and availability of these data in the public domain will become standard of care, making this audit a baseline for longitudinal observation, assessing the impact of interventions, and contributing to the development of local guidelines

    Complications of the Treatment of Childhood Cancer

    No full text

    Carbon Dioxide Embolism Associated with Transanal Total Mesorectal Excision Surgery: A Report From the International Registries

    No full text
    BACKGROUND: Carbon dioxide embolus has been reported as a rare but clinically important risk associated with transanal total mesorectal excision surgery. To date, there exists limited data describing the incidence, risk factors, and management of carbon dioxide embolus in transanal total mesorectal excision. OBJECTIVE: This study aimed to obtain data from the transanal total mesorectal excision registries to identify trends and potential risk factors for carbon dioxide embolus specific to this surgical technique. DESIGN: Contributors to both the LOREC and OSTRiCh transanal total mesorectal excision registries were invited to report their incidence of carbon dioxide embolus. Case report forms were collected detailing the patient-specific and technical factors of each event. SETTINGS: The study was conducted at the collaborating centers from the international transanal total mesorectal excision registries. MAIN OUTCOME MEASURES: Characteristics and outcomes of patients with carbon dioxide embolus associated with transanal mesorectal excision were measured. RESULTS: Twenty-five cases were reported. The incidence of carbon dioxide embolus during transanal total mesorectal excision is estimated to be 480.4% (25/6375 cases). A fall in end tidal carbon dioxide was noted as the initial feature in 22 cases, with 13 (52%) developing signs of hemodynamic compromise. All of the events occurred in the transanal component of dissection, with mean (range) insufflation pressures of 15mm Hg (12\u201320mm Hg). Patients were predominantly (68%) in a Trendelenburg position, between 30\ub0 and 45\ub0. Venous bleeding was reported in 20 cases at the time of carbon dioxide embolus, with periprostatic veins documented as the most common site (40%). After carbon dioxide embolus, 84% of cases were completed after hemodynamic stabilization. Two patients required cardiopulmonary resuscitation because of cardiovascular collapse. There were no deaths. LIMITATIONS: This is a retrospective study surveying reported outcomes by surgeons and anesthetists. CONCLUSIONS: Surgeons undertaking transanal total mesorectal excision must be aware of the possibility of carbon dioxide embolus and its potential risk factors, including venous bleeding (wrong plane surgery), high insufflation pressures, and patient positioning. Prompt recognition and management can limit the clinical impact of such events. See Video Abstract at http://links. lww.com/DCR/A961
    corecore