16 research outputs found

    Percutaneous posterolateral approach for the simulation of a far-lateral disc herniation in an ovine model

    Get PDF
    This work describes a minimally invasive damage model for ovine lumbar discs via partial nucleotomy using a posterolateral approach. Two cadavers were dissected to analyze the percutaneous corridor. Subsequently, 28 ovine had their annulus fibrosus punctured via awl penetration under fluoroscopic control and nucleus pulposus tissue removed via rongeur. Efficacy was assessed by animal morbidity, ease of access to T12-S1 disc spaces, and production of a mechanical injury as verified by discography, radiography, and histology. T12-S1 were accessible with minimal nerve damage morbidity. Scar tissue sealed the disc puncture site in all animals within 6 weeks, withstanding 1 MP of intradiscal pressure. Partial nucleotomy led to a significant reduction in intervertebral disk height and an increased histological degeneration score. Inducing a reproducible injury pattern of disc degeneration required minimal time, effort, and equipment. The posterolateral approach allows operation on several discs within a single surgery and multiple animal surgeries within a single day.Peer reviewe

    Micro-computed tomography, scanning electron microscopy and energy X-ray spectroscopy studies of facet joint degeneration : A comparison to clinical imaging

    Get PDF
    Segmental degeneration in the human lumbar spine affects both the intervertebral discs and facet joints. Facet joint degeneration not only affects the cartilage surface, but also alters the cellular properties of the cartilage tissue and the structure of the subchondral bone. The primary focus of this study is the investigation of these microstructural changes that are caused by facet joint degeneration. Microstructural analyses of degenerated facet joint samples, obtained from patients following operative lumbar interbody fusion, have not previously been extensively investigated. This study analyzes human facet joint samples from the inferior articular process using scanning electron microscopy, micro-computed tomography, and energy dispersive X-ray spectroscopy to evaluate parameters of interest in facet joint degeneration such as elemental composition, cartilage layer thickness and cell density, calcification zone thickness, subchondral bone portion, and trabecular bone porosity. These microstructural analyses demonstrate fragmentation, cracking, and destruction of the cartilage layer, a thickened calcification zone, localized calcification areas, and cell cluster formation as pathological manifestations of facet joint degeneration. The detailed description of these microstructural changes is critical for a comprehensive understanding of the pathology of facet joint degeneration, as well as the subsequent development and efficacy analysis of regenerative treatment strategies.Peer reviewe

    Microstructure analysis method for evaluating degenerated intervertebral disc tissue

    Get PDF
    Degeneration of intervertebral disc (IVD) tissue is characterized by several structural changes that result in variations in disc physiology and loss of biomechanical function. The complex process of degeneration exhibits highly intercorrelated biomechanical, biochemical, and cellular interactions. There is currently some understanding of the cellular changes in degenerated intervertebral disc tissue, but microstructural changes and deterioration of the tissue matrix has previously been rarely explored. In this work, sequestered IVD tissue was successfully characterized using histology, light microscopy, and scanning electron microscopy (SEM) to quantitatively evaluate parameters of interest for intervertebral disc degeneration (IDD) such as delamination of the collagenous matrix, cell density, cell size, and extra cellular matrix (ECM) thickness. Additional qualitative parameters investigated included matrix fibration and irregularity, neovascularization of the IVD, granular inclusions in the matrix, and cell cluster formation. The results of this study corroborated several previously published findings, including those positively correlating female gender and IVD cell density, age and cell size, and female gender and ECM thickness. Additionally, an array of quantitative and qualitative investigations of IVD degeneration could be successfully evaluated using the given methodology, resin-embedded SEM in particular. SEM is especially practical for studying micromorphological changes in tissue, as other microscopy methods can cause artificial tissue damage due to the preparation method. Investigation of the microstructural changes occurring in degenerated tissue provides a greater understanding of the complex process of disc degeneration as a whole. Developing a more complete picture of the degenerative changes taking place in the intervertebral disc is crucial for the advancement and application of regenerative therapies based on the pathology of intervertebral disc degeneration. (C) 2016 Elsevier Ltd. All rights reserved.Peer reviewe

    Micro-CT evaluation of asymmetrical ovine intervertebral disc height loss from surgical approach

    Get PDF
    The primary goal of this study is to clearly define and evaluate new intervertebral disc height parameters in analysing the morphological pathology of disc degeneration for application in damage model and regeneration therapy development, as well as applying traditional variables to 3-D characterization methods. A posterolateral surgical approach was used to induce disc degeneration in an ovine model. At 12-months post-operation, sheep vertebral segments were removed and characterized using micro-CT to evaluate disc height parameters in regard to injury localization. Statistically significant differences between the disc height loss of the left and right side of the disc, consistent with the lateral surgical approach used were seen using the modified average disc height method by Dabbs et al. However, convexity index and the newly proposed Cross Tilt Index did not conclusively demonstrate a difference. Two-dimensional morphological evaluations can be applied in 3-D to provide a more complete picture of disc height loss for injury models. New 3-D parameters that are tailored to the type of surgical approach used should be investigated, with the 9-point system described herein providing a useful basis for derived values. Additionally, the surgical approach chosen when artificially injuring the disc can result in asymmetrical degeneration, as indicated by uneven disc height loss.Peer reviewe

    The influence of oral cavity physiological parameters: temperature, pH, and swelling on the performance of denture adhesives - in vitro study

    No full text
    Abstract Background The various physical and chemical conditions within the oral cavity are hypothesized to have a significant influence on the behavior of denture adhesives and therefore the overall comfort of denture wearers. As such, this study aims to understand the influence of oral cavity physiological parameters such as temperature (17 to 52 °C), pH (2, 7, 10), and denture adhesive swelling due to saliva (20–120%) on the behavior of denture adhesives. This study further aims to emphasize the need for a collective approach to modelling the in-situ behavior of denture adhesives. Methods Rheological measurements were carried out using the Super Polygrip Ultra fresh brand denture adhesive cream to evaluate its storage modulus (G´) and loss modulus (G´´) values at a range of physiologically relevant temperatures, pH values, and degrees of swelling, to represent and characterize the wide variety of conditions that occur within the oral cavity. Results Rheological data was recorded with respect to variation of temperature, pH, and swelling. Overall, it can be seen that the physiological conditions of the oral cavity have an influence on the rheological properties of the denture adhesive cream. Specifically, our data indicates that the adhesive’s mechanical properties are weakly influenced by pH, but do change with respect to the temperature in the oral cavity and the swelling rate of the adhesive. Conclusions Our results suggest that the collective inter-play of the parameters pH, temperature and swelling ratio have an influence on the behavior of the denture adhesive. The results clearly highlight the need for developing a multi-parameter viscoelastic material model to understand the collective influence of physiological parameters on the performance of denture adhesives. Multi-parameter models can also potentially be utilized in numerically simulating denture adhesives using finite element simulations
    corecore