20 research outputs found

    Polymerization shrinkage stress of composites photoactivated by different light sources

    Get PDF
    The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5%). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.Este estudo comparou a contração de polimerização de resinas compostas fotoativadas por luz halógena (QTH) e diodo emissor de luz (LED). Foram confeccionados bastões de vidro (5,0 mm x 5,0 cm), e uma de suas extremidades sofreu jateamento com óxido de alumínio, sobre a qual foi aplicado um adesivo e fotoativado com luz halógena. Os bastões de vidro foram acoplados verticalmente, em pares, em uma máquina universal de ensaios (EMIC DL-2000) e as resinas compostas aplicadas no bastão inferior. A distância entre os bastões foi padronizada em 2 mm e um extensômetro foi acoplado a eles. As resinas foram fotoativadas (n=20), sendo 10 por QTH e 10 por LED utilizando dois aparelhos posicionados em lados opostos, acionados simultaneamente por 40 s. A tensão de contração foi analisada em dois momentos: logo após a polimerização (t40s) e 10 min após (t10min). A tensão de contração apresentada por todas as resinas foi maior em t10min do que em t40s, independente da fonte ativadora. A resina de micropartículas apresentou menores valores de tensão de contração com valores estatisticamente significantes em relação às demais resinas. Para as resinas híbrida e microhíbrida não houve influência da unidade ativadora sobre a tensão de contração, com exceção para a resina de micropartículas em t10min. Concluiu-se que a composição da resina composta foi o fator que mais interferiu na tensão de contração da resina composta

    Effectiveness of a new toothbrush design versus a conventional tongue scraper in improving breath odor and reducing tongue microbiota

    Get PDF
    For centuries, specific instruments or regular toothbrushes have routinely been used to remove tongue biofilm and improve breath odor. Toothbrushes with a tongue scraper on the back of their head have recently been introduced to the market. The present study compared the effectiveness of a manual toothbrush with this new design, i.e., possessing a tongue scraper, and a commercial tongue scraper in improving breath odor and reducing the aerobic and anaerobic microbiota of tongue surface. The evaluations occurred at 4 moments, when the participants (n=30) had their halitosis quantified with a halimeter and scored according to a 4-point scoring system corresponding to different levels of intensity. Saliva was collected for counts of aerobic and anaerobic microorganisms. Data were analyzed statistically by Friedman's test (p<0.05). When differences were detected, the Wilcoxon test adjusted for Bonferroni correction was used for multiple comparisons (group to group). The results confirmed the importance of mechanical cleaning of the tongue, since this procedure provided an improvement in halitosis and reduction of aerobe and anaerobe counts. Regarding the evaluated methods, the toothbrush's tongue scraper and conventional tongue scraper had a similar performance in terms of breath improvement and reduction of tongue microbiota, and may be indicated as effective methods for tongue cleaning

    Risk of Fungal Infection to Dental Patients

    Get PDF
    Fungi can cause various diseases, and some pathogenic fungi have been detected in the water of dental equipment. This environment offers suitable conditions for fungal biofilms to emerge, which can facilitate mycological contamination. This study verified whether the water employed in the dental units of two dental clinics at the University of Franca was contaminated with fungi. This study also evaluated the ability of the detected fungi to form biofilms. The high-revving engine contained the largest average amount of fungi, 14.93 ± 18.18 CFU/mL. The main fungal species verified in this equipment belonged to the genera Aspergillus spp., Fusarium spp., Candida spp., and Rhodotorula spp. Among the isolated filamentous fungi, only one fungus of the genus Fusarium spp. did not form biofilms. As for yeasts, all the Candida spp. isolates grew as biofilm, but none of the Rhodotorula spp. isolates demonstrated this ability. Given that professionals and patients are often exposed to water and aerosols generated by the dental procedure, the several fungal species detected herein represent a potential risk especially to immunocompromised patients undergoing dental treatment. Therefore, frequent microbiological monitoring of the water employed in dental equipment is crucial to reduce the presence of contaminants

    Estudo comparativo de técnicas de screening para avaliação da atividade anti-bacteriana de extratos brutos de espécies vegetais e de substâncias puras

    Full text link
    In this work, the effectiveness of four screening techniques (three techniques of the diffusion method and one microdilution broth method) were compared. Evaluated were the ethanolic and dichloromethanic extracts of Miconia rubiginosa (Melastomataceae) against six standard bacteria (ATCC). The results showed statistical disagreement among the three diffusion techniques. Among the diffusion techniques, the well technique displayed the best result. However the microdilution broth method demonstrated to be the most adequate method to evaluate the antibacterial activity of plant crude extracts and pure compounds when compared to the other methodologies

    Abrasion resistance of composites polymerized by light-emitting diodes (LED) and halogen light-curing units

    No full text
    This study compared the abrasion resistance of direct composite resins cured by light-emitting diodes (LED) and halogen light-curing units. Twenty specimens (12 mm in diameter; 1.0 mm thick) of each composite resin [TPH (Dentsply); Definite (Degussa); Charisma (Heraus Kulzer)] were prepared using a polytetrafluoroethylene matrix. Ten specimens per material were cured with the LED source and 10 with the halogen lamp for 40 s. The resin discs were polished, submitted to initial surface roughness reading (Ra initial - mum) in a roughness tester and stored in water at 37°C for 15 days. The specimens were weighed (M1) and submitted to simulated toothbrushing using slurry of water and dentifrice with high abrasiveness. After 100 minutes in the toothbrushing simulator, the specimens were cleaned, submitted to a new surface roughness reading (Ra final - mum) and reweighed (M2). Mass loss was determined as the difference between M1 and M2. Data were recorded and analyzed statistically by one-way ANOVA and Tukey Test at 5% significance level. The composite resin with greater size of inorganic fillers (TPH) showed the lowest mass loss and surface roughness means, indicating a higher resistance to toothbrush abrasion (p<0.05). Definite cured with LED presented the least resistance to toothbrush abrasion, showing the highest means of surface roughness and mass loss (p<0.05). The LED source did not show the same effectiveness as the halogen lamp for polymerizing this specific composite resin. When the composite resins were cured a halogen LCU, no statistically significant difference was observed among the materials (p>0.05). It may be concluded that the type of light-curing unit and the resin composition seemed to interfere with the materials' resistance to abrasion

    Desensitizing bioactive agents improves bond strength of indirect resin-cemented restorations: preliminary results

    Get PDF
    OBJECTIVE: The aim of this study was to assess the bond strength of indirect composite restorations cemented with a resin-based cement associated with etch-and-rinse and self-etching primer adhesive systems to dentin treated or not with a bioactive material. MATERIALS AND METHOD: Twenty bovine incisor crowns had the buccal enamel removed and the dentin ground flat. The teeth were assigned to 4 groups (n=5): Group I: acid etching + Prime &amp; Bond NT (Dentsply); Group II: application of a bioactive glass (Biosilicato®)+ acid etching + Prime &amp; Bond NT; Group III: One-up Bond F (J Morita); Group IV: Biosilicato® + One-up Bond F. Indirect composite resin (Artglass, Kulzer) cylinders (6x10mm) were fabricated and cemented to the teeth with a dual-cure resin-based cement (Enforce, Dentsply). After cementation, the specimens were stored in artificial saliva at 37ºC for 30 days and thereafter tested in tensile strength in a universal testing machine (EMIC) with 50 kgf load cell at a crosshead speed of 1 mm/min. Failure modes were assessed under scanning electron microscopy. Data were analyzed statistically by ANOVA and Tukey's test (95% level of confidence). RESULTS: Groups I, II and III had statistically similar results (p>0.05). Group IV had statistically significant higher bond strength means (p<0.05) than the other groups. The analysis of the debonded surfaces showed a predominance of adhesive failure mode for Group III and mixed failure mode for the other groups. CONCLUSION: The use of desensitizing agent did not affect negatively the bonding of the indirect composite restorations to dentin, independently of the tested adhesive systems

    Antimicrobial and mechanical properties of acrylic resins with incorporated silver-zinc zeolite - part I

    No full text
    Objective: The purpose of this in vitro study was to evaluate the antimicrobial activity of acrylic resins containing different percentages of silver and zinc zeolite, and to assess whether the addition of zeolite alters the flexural and impact strength of the resins. Background: The characteristics of acrylic resins support microorganism development that can threaten the health of the dentures user. Material and methods: A microwave-polymerised (Onda-Cryl) and two heat-polymerised (QC20 and Lucitone 550) acrylic resins were used. The materials were handled according to the manufacturers` instructions. Fifty rectangular-shaped specimens (8 x 10 x 4mm) were fabricated from each resin and assigned to 5 groups (n = 10) according to their percentage of Irgaguard B5000 silver-zinc zeolite (0%- control, 2.5%, 5.0%, 7.5% and 10%). Flexural strength and Izod impact strength were evaluated. The antimicrobial activity against two strains of Candida albicans and two strains of Streptococcus mutans was assessed by agar diffusion method. Data were analysed statistically by one-way ANOVA and Tukey`s test at 5% significance level. Results: The addition of 2.5% of Irgaguard B5000 to the materials resulted in antimicrobial activity against all strains. Flexural strength decreased significantly with the addition of 2.5% (QC20 and Lucitone 550) and 5.0% (Onda-Cryl) of Irgaguard B5000. The impact strength decreased significantly with the addition of 2.5% (Lucitone 550) and 5.0% (QC20 and Onda-Cryl) of zeolite. Conclusion: The addition of silver-zinc zeolite to acrylic resins yields antimicrobial activity, but may affect negatively the mechanical properties, depending on the percentage of zeolite

    Color stability of dental ceramics submitted to artificial accelerated aging after repeated firings

    No full text
    Statement of problem: Color stability is an important factor to ensure the long-term clinical success of ceramic restorations. There is a lack of information on how color is affected by fabrication procedures, such as the number of firings. Purpose: The purpose of this study was to evaluate the effects that the number of firings and type of substrate have on the color stability of dental ceramic submitted to artificial accelerated aging. Material and methods: Sixty specimens were fabricated: 30 metal ceramic (Verabond II + IPS d.SIGN) and 30 all-ceramic (IPS d.SIGN). Specimens were divided into 3 groups (n=10), and submitted to 2, 3, or 4 firings (±900°C), respectively, according to the manufacturer's instructions. Color readings were obtained with a spectrophotometer before and after artificial accelerated aging, and L*, a*, and b* coordinates and total color variation (ΔE) were analyzed (2-way ANOVA, Bonferroni, α=05). Results: For metal ceramic specimens, differences for the L* coordinates were significant (P<.05) only for the group submitted to 3 firings. With respect to the all-ceramic specimens, smaller L* coordinates were obtained for greater a* and b* coordinates, indicating that the greater the number of firings, the darker and more reddish/yellowish the specimen. All ΔE values, for all groups, were below 1.0. All-ceramic specimens submitted to 3 and 4 firings presented ΔE means differing statistically (P<.05) from those of the metal ceramic group. Conclusions: The type of substrate and number of firings affected the color stability of the ceramic material tested. Artificial accelerated aging did not produce perceptible color stability changes (ΔE<1.0).1011131
    corecore