105 research outputs found
EANM consensus document on the use of [18F]FDG PET/CT in fever and inflammation of unknown origin
Purpose: Patients with fever and inflammation of unknown origin (FUO/IUO) are clinically challenging due to variable clinical presentations with nonspecific symptoms and many differential diagnoses. Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) is increasingly used in FUO and IUO, but the optimal diagnostic strategy remains controversial. This consensus document aims to assist clinicians and nuclear medicine specialists in the appropriate use of [18F]FDG-PET/CT in FUO and IUO based on current evidence. Methods: A working group created by the EANM infection and inflammation committee performed a systematic literature search based on PICOs with “patients with FUO/IUO” as population, “[18F]FDG-PET/CT” as intervention, and several outcomes including pre-scan characteristics, scan protocol, diagnostic yield, impact on management, prognosis, and cost-effectiveness. Results: We included 68 articles published from 2001 to 2023: 9 systematic reviews, 49 original papers on general adult populations, and 10 original papers on specific populations. All papers were analysed and included in the evidence-based recommendations. Conclusion: FUO and IUO remains a clinical challenge and [18F]FDG PET/CT has a definite role in the diagnostic pathway with an overall diagnostic yield or helpfulness in 50–60% of patients. A positive scan is often contributory by directly guiding treatment or subsequent diagnostic procedure. However, a negative scan may be equally important by excluding focal disease and predicting a favorable prognosis. Similar results are obtained in specific populations such as ICU-patients, children and HIV-patients
EANM consensus document on the use of [18F]FDG PET/CT in fever and inflammation of unknown origin
PURPOSE: Patients with fever and inflammation of unknown origin (FUO/IUO) are clinically challenging due to variable clinical presentations with nonspecific symptoms and many differential diagnoses. Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[ 18F]fluoro-D-glucose ([ 18F]FDG) is increasingly used in FUO and IUO, but the optimal diagnostic strategy remains controversial. This consensus document aims to assist clinicians and nuclear medicine specialists in the appropriate use of [ 18F]FDG-PET/CT in FUO and IUO based on current evidence. METHODS: A working group created by the EANM infection and inflammation committee performed a systematic literature search based on PICOs with "patients with FUO/IUO" as population, "[ 18F]FDG-PET/CT" as intervention, and several outcomes including pre-scan characteristics, scan protocol, diagnostic yield, impact on management, prognosis, and cost-effectiveness. RESULTS: We included 68 articles published from 2001 to 2023: 9 systematic reviews, 49 original papers on general adult populations, and 10 original papers on specific populations. All papers were analysed and included in the evidence-based recommendations.CONCLUSION: FUO and IUO remains a clinical challenge and [ 18F]FDG PET/CT has a definite role in the diagnostic pathway with an overall diagnostic yield or helpfulness in 50-60% of patients. A positive scan is often contributory by directly guiding treatment or subsequent diagnostic procedure. However, a negative scan may be equally important by excluding focal disease and predicting a favorable prognosis. Similar results are obtained in specific populations such as ICU-patients, children and HIV-patients. </p
Cardiac Rhythm Management Device Infections: Imaging Examinations to Direct Replacement Timing
Dapagliflozin-Induced Myocardial Flow Reserve Improvement is not Associated with HDL Ability to Stimulate Endothelial Nitric Oxide Production
Background: Sodium-glucose cotransporter-2 (SGLT2) inhibitors have shown controversial results in modulating plasma lipids in clinical trials. Most studies found slight increases in high-density lipoprotein (HDL) cholesterol but few have provided evidence on HDL functionality with disappointing results. However, there is broad agreement that these drugs provide cardiovascular protection through several mechanisms. Our group demonstrated that dapagliflozin improves myocardial flow reserve (MFR) in patients with type 2 diabetes (T2D) with coronary artery disease (CAD). The underlying mechanisms are still unknown, although in vitro studies have suggested the involvement of nitric oxide (NO). Aim: To investigate changes in HDL-mediated modulation of NO production with dapagliflozin and whether there is an association with MFR. Methods: Sixteen patients with CAD-T2D were enrolled and randomized 1:1 to dapagliflozin or placebo for 4 weeks. Blood samples were collected before and after treatment for each group. The ability of HDL to stimulate NO production in endothelial cells was tested in vitro by incubating human umbilical vein endothelial cells (HUVEC) with apoB-depleted (apoB-D) serum of these patients. The production of NO was assessed by fluorescent assay, and results were expressed as fold versus untreated cells. Results: Change in HDL-mediated NO production remained similar in dapagliflozin and placebo group, even after adjustment for confounders. There were no significant correlations between HDL-mediated NO production and MFR either at baseline or after treatment. No changes were found in HDL cholesterol in either group, while low-density lipoprotein cholesterol (LDL cholesterol) significantly decreased compared to baseline only in treatment group (p = 0.043). Conclusions: In patients with T2D-CAD, beneficial effects of dapagliflozin on coronary microcirculation seem to be unrelated to HDL functions. However, HDL capacity to stimulate NO production is not impaired at baseline; thus, the effect of drug treatments would be negligible. To conclude, we can assume that HDL-independent molecular pathways are involved in the improvement of MFR in this population. Trial registration: EudraCT No. 2016-003614-27; ClinicalTrials.gov Identifier: NCT03313752
18F-fluoro-deoxy-glucose focal uptake in very small pulmonary nodules: fact or artifact? Case reports
ABSTRACT: BACKGROUND: F-fluoro-deoxy-glucose (18F-FDG) positron emission tomography integrated/combined with computed tomography (PET-CT) provides the best diagnostic results in the metabolic characterization of undetermined solid pulmonary nodules. The diagnostic performance of 18F-FDG is similar for nodules measuring at least 1 cm and for larger masses, but few data exist for nodules smaller than 1 cm. CASE PRESENTATION: We report five cases of oncologic patients showing focal lung 18F-FDG uptake on PET-CT in nodules smaller than 1 cm. We also discuss the most common causes of 18F-FDG false-positive and false-negative results in the pulmonary parenchyma. In patient 1, contrast-enhanced CT performed 10 days before PET-CT did not show any abnormality in the site of uptake; in patient 2, high-resolution CT performed 1 month after PET showed a bronchiole filled with dense material interpreted as a mucoid impaction; in patient 3, contrast-enhanced CT performed 15 days before PET-CT did not identify any nodules; in patients 4 and 5, contrast-enhanced CT revealed a nodule smaller than 1 cm which could not be characterized. The 18F-FDG uptake at follow-up confirmed the malignant nature of pulmonary nodules smaller than 1 cm which were undetectable, misinterpreted, not recognized or undetermined at contrast-enhanced CT. CONCLUSION: In all five oncologic patients, 18F-FDG was able to metabolically characterize as malignant those nodules smaller than 1 cm, underlining that: 18F-FDG uptake is not only a function of tumor size but it is strongly related to the tumor biology; functional alterations may precede morphologic abnormalities. In the oncologic population, especially in higher-risk patients, PET can be performed even when the nodules are smaller than 1 cm, because it might give an earlier characterization and, sometimes, could guide in the identification of alterations missed on CT
Recovery of cardiovascular diagnostic testing in Italy 1 year after coronavirus disease-2019 outbreak compared with other countries in Europe and worldwide: results from the International Atomic Energy Agency INCAPS COVID 2 survey
AimsRecovery of cardiovascular diagnostic testing in Italy after the coronavirus disease-2019 (COVID-19) pandemic has not been quantified. The study aims to describe cardiac diagnostic procedure volumes, centres practice and protocols, and staff members’ well-being 1 year after COVID-19 outbreak in Italy.Methods and resultsA global survey was conducted by the International Atomic Energy Agency to evaluate changes in cardiac diagnostic procedure volumes in April 2021. Evaluated procedures were transoesophageal echocardiogram, coronary computed tomography angiography, coronary artery calcium scanning, nuclear medicine infection studies, invasive coronary angiography, rest and stress transthoracic echocardiogram, cardiac magnetic resonance, single-photon emission computed tomography and positron emission tomography, and stress electrocardiogram. Data were compared with April 2020 and March 2019. Forty-two Italian centres took part in the survey. In April 2020, there was a 72% decrease of median volumes of cardiac diagnostic procedures compared with March 2019. In April 2021, volumes of cardiac diagnostic procedures remained decreased by 3% when compared with March 2019. Stress electrocardiogram, coronary computed tomography angiography, and stress cardiac magnetic resonance volumes increased in April 2021 compared with baseline (29%, 6%, and 16%, respectively). The majority of centres had adopted physical distancing measures (93%), COVID-19 screening through questionnaires (76%), or temperature checks (93%). Twenty-five per cent of physicians at Italian responding sites reported excessive levels of psychological stress.ConclusionIn April 2021, volumes of cardiac diagnostic procedures at Italian responding sites were still recovering. Centres had implemented several adaptations to ensure the provision of care to their patients. Even 1 year after the pandemic, a substantial minority of Italian healthcare providers were still experiencing excessive psychological stress
Recovery of cardiovascular diagnostic testing in Italy 1 year after coronavirus disease-2019 outbreak compared with other countries in Europe and worldwide: results from the International Atomic Energy Agency INCAPS COVID 2 survey
AIMS: Recovery of cardiovascular diagnostic testing in Italy after the coronavirus disease-2019 (COVID-19) pandemic has not been quantified. The study aims to describe cardiac diagnostic procedure volumes, centres practice and protocols, and staff members' well-being 1 year after COVID-19 outbreak in Italy. METHODS AND RESULTS: A global survey was conducted by the International Atomic Energy Agency to evaluate changes in cardiac diagnostic procedure volumes in April 2021. Evaluated procedures were transoesophageal echocardiogram, coronary computed tomography angiography, coronary artery calcium scanning, nuclear medicine infection studies, invasive coronary angiography, rest and stress transthoracic echocardiogram, cardiac magnetic resonance, single-photon emission computed tomography and positron emission tomography, and stress electrocardiogram. Data were compared with April 2020 and March 2019. Forty-two Italian centres took part in the survey. In April 2020, there was a 72% decrease of median volumes of cardiac diagnostic procedures compared with March 2019. In April 2021, volumes of cardiac diagnostic procedures remained decreased by 3% when compared with March 2019. Stress electrocardiogram, coronary computed tomography angiography, and stress cardiac magnetic resonance volumes increased in April 2021 compared with baseline (29%, 6%, and 16%, respectively). The majority of centres had adopted physical distancing measures (93%), COVID-19 screening through questionnaires (76%), or temperature checks (93%). Twenty-five per cent of physicians at Italian responding sites reported excessive levels of psychological stress. CONCLUSION: In April 2021, volumes of cardiac diagnostic procedures at Italian responding sites were still recovering. Centres had implemented several adaptations to ensure the provision of care to their patients. Even 1 year after the pandemic, a substantial minority of Italian healthcare providers were still experiencing excessive psychological stress
Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world
Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic.
Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality.
Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States.
Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis.
Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
Impact of COVID-19 on Cardiovascular Testing in the United States Versus the Rest of the World
Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-U.S. institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic. Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality. Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States. Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis. Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
- …