531 research outputs found

    Combining Lanthanides with PyBox Ligands: A Simple Route to Circularly Polarized Light Emitters**

    Get PDF
    AbstractWe report the facile synthesis of TbIII and EuIII adducts able to elicit circularly polarized luminescence. Both the sensitization of the lanthanide‐ion‐centered luminescence (i. e. the antenna effect) and the chiral environment around the metal ions are brought about by commercially available enantiopure 2,6‐bis(oxazolinyl)pyridine ligands (PyBox). This strategy is promising for the development of a wide range of new and simple circularly polarized luminescence (CPL) active LnIII adducts, thanks to the fine tunability of the chemical structure of the PyBox ligands

    Taking advantage of Co(ii) induced enhanced VCD for the fast and sensitive determination of enantiomeric excess

    Get PDF
    Co(II) induces a large VCD signal enhancement, which overcomes the low sensitivity of VCD and opens new perspectives in quantitative VCD. We used a stereodynamic system, where the analyte determines the chirality of the Co(II) coordination sphere. The strong VCD signals stand out the baseline, which allows for their rapid and accurate quantitation. This lends itself to the first general method for the ee determination of α-amino acids based on vibrational circular dichroism and constitutes a model for the design of sensitive quantitative assays based on VCD

    Circularly Polarised Luminescence in Enantiopure Samarium and Europium Cryptates

    Get PDF
    Circularly polarised luminescence (CPL) is a chiroptical phenomenon gaining more and more attention, as the availability of the necessary spectrometers is getting better and first applications in bioimaging or for the preparation of OLEDs (organic light emitting diodes) are coming within range. Until now most examples of distinctly CPL-active compounds were europium and terbium complexes though theoretically the electronic structure of samarium should be as suitable as the one of terbium. This discrepancy can be accounted for by the high susceptibility of samarium to non-radiative deactivation processes. The aim of this study was to strategically circumvent this difficulty by the use of a ligand scaffold which has already proven to efficiently suppress these processes, namely the cryptates. The prepared partly deuterated samarium and europium complexes exhibit distinct circularly polarised luminescence with dissymmetry factors up to glum=+0.13 (SmIII) or glum=−0.19 (EuIII)

    Chiroptical methods in a wide wavelength range for obtaining Ln3+complexes with circularly polarized luminescence of practical interest

    Get PDF
    We studied enantiopure chiral trivalent lanthanide (Ln3+= La3+, Sm3+, Eu3+, Gd3+, Tm3+, and Yb3+) complexes with two fluorinated achiral tris(β-diketonate) ligands (HFA = hexafluoroacetylacetonate and TTA = 2-thenoyltrifluoroacetonate), incorporating a chiral bis(oxazolinyl)pyridine (PyBox) unit as a neutral ancillary ligand, by the combined use of optical and chiroptical methods, ranging from UV to IR both in absorption and circular dichroism (CD), and including circularly polarized luminescence (CPL). Ultimately, all the spectroscopic information is integrated into a total and a chiroptical super-spectrum, which allows one to characterize a multidimensional chemical space, spanned by the different Ln3+ions, the acidity and steric demand of the diketone and the chirality of the PyBox ligand. In all cases, the Ln3+ions endow the systems with peculiar chiroptical properties, either allied to f-f transitions or induced by the metal onto the ligand. In more detail, we found that Sm3+complexes display interesting CPL features, which partly superimpose and partly integrate the more common Eu3+properties. Especially, in the context of security tags, the pair Sm/Eu may be a winning choice for chiroptical barcoding

    Effect of the Counterion on Circularly Polarized Luminescence of Europium(III) and Samarium(III) Complexes

    Get PDF
    Each enantiopure europium(III) and samarium(III) nitrate and triflate complex of the ligand L, with L = N,N'-bis(2-pyridylmethylidene)-1,2-(R,R + S,S)-cyclohexanediamine ([LnL(tta)2]·NO3 and [LnL(tta)2(H2O)]·CF3SO3, where tta = 2-thenoyltrifluoroacetylacetonate) has been synthesized and characterized from a spectroscopic point of view, using a chiroptical technique such as electronic circular dichroism (ECD) and circularly polarized luminescence (CPL). In all cases, both ligands are capable of sensitizing the luminescence of both metal ions upon absorption of light around 280 and 350 nm. Despite small differences in the total luminescence (TL) and ECD spectra, the CPL activity of the complexes is strongly influenced by a concurrent effect of the solvent and counterion. This particularly applies to europium(III) complexes where the CPL spectra in acetonitrile can be described as a weighed linear combination of the CPL spectra in dichloromethane and methanol, which show nearly opposite signatures when their ligand stereochemistries are the same. This phenomenon could be related to the presence of equilibria interconverting solvated, anion-coordinated complexes and isomers differing by the relative orientation of the tta ligands. The difference between some bond lengths (M-N bonds, in particular) in the different species could be at the basis of such an unusual CPL activity

    A circular dichroism study of the protective role of polyphosphoesters polymer chains in polyphosphoester‐myoglobin conjugates

    Get PDF
    Protein-polymer conjugates are a blooming class of hybrid systems with high biomedical potential. Despite a plethora of papers on their biomedical properties, the physical–chemical characterization of many protein-polymer conjugates is missing. Here, we evaluated the thermal stability of a set of fully-degradable polyphosphoester-protein conjugates by variable temperature circular dichroism, a common but powerful technique. We extensively describe their thermodynamic stability in different environments (in physiological buffer or in presence of chemical denaturants, e.g., acid or urea), highlighting the protective role of the polymer in preserving the protein from denaturation. For the first time, we propose a simple but effective protocol to achieve useful information on these systems in vitro, useful to screen new samples in their early stages

    Modular chiral Eu(iii) complexes for efficient circularly polarized OLEDs

    Get PDF
    Achieving both high dissymmetry factors and strong emission in circularly polarized (CP) luminescent materials and, at the same time, compatibility with manufacturing processes for organic electronic devices, is a crucial issue for reliable applications of CP emitters in many fields, such as chiral electronics and optoelectronics. In this communication, we show that the independent choice of the sensitizing and the chirality inducing ligands allows europium(III) complexes to meet the multiple requirements for solution processed efficient CP electroluminescent devices

    Remarkable near-infrared chiroptical properties of chiral Yb, Tm and Er complexes

    Get PDF
    We carried out a study of absorption (CD) and emission (CPL) chiroptical properties in the NIR region of two sets of Yb, Tm and Er complexes. The two complexes include a D3 symmetric, [TMG-H+]3Ln(BINOLate)3 (Ln = Yb, Tm, Er; TMG = 1,1,3,3-tetramethylguanidine; BINOLate = 1,1'-bi-2-naphtholate), and a tetrakis, C4 symmetric, CsLn(hfbc)4 (Ln = Yb, Tm, Er; hfbc = 3-heptafluorobutylyrylcamphorate). The lanthanides studied gave access to three discrete energy domains, Yb (900-1040 nm), Tm (1180-1240 nm) and Er (1430-1600 nm) in which the chiroptical activity was assessed using gabs (and glum for Yb complexes). Exceptionally high discrimination between left and right circularly polarised light was observed, with values up to almost the theoretical maximum (±2)

    How much do needlestick injuries cost? a systematic review of the economic evaluations of needlestick and sharps injuries among healthcare personnel

    Get PDF
    objective. To provide an overview of the economic aspects of needlestick and sharps injury (NSI) management among healthcare personnel (HCP) within a Health Technology Assessment project to evaluate the impact of safety-engineered devices on health care methods. A systematic review of economic analyses related to NSIs was performed in accordance with the PRISMA statement and by searching PubMed and Scopus databases (January 1997–February 2015). Mean costs were stratified by study approach (modeling or data driven) and type of cost (direct or indirect). Costs were evaluated using the CDC operative definition and converted to 2015 International US dollars (Int).results.Atotalof14studieswereretrieved:8datadrivenstudiesand6modelingstudies.Amongthem,11studiesprovideddirectandindirectcostsand3studiesprovidedonlydirectcosts.Themedianofthemeansforaggregate(direct+indirect)costswasInt). results. A total of 14 studies were retrieved: 8 data-driven studies and 6 modeling studies. Among them, 11 studies provided direct and indirect costs and 3 studies provided only direct costs. The median of the means for aggregate (direct + indirect) costs was Int747 (range, Int199Int199–Int1,691). The medians of the means for disaggregated costs were Int425(range,Int425 (range, Int48–Int1,516)fordirectcosts(9studies)andInt1,516) for direct costs (9 studies) and Int322 (range, Int152Int152–Int 413) for indirect costs (6 studies). When compared with data-driven studies, modeling studies had higher disaggregated and aggregated costs, but data-driven studies showed greater variability. Indirect costs were consistent between studies, mostly referring to lost productivity, while direct costs varied widely within and between studies according to source infectivity, HCP susceptibility, and post-exposure diagnostic and prophylactic protocols. Costs of treating infections were not included, and intangible costs could equal those associated with NSI medical evaluations. conclusions. NSIs generate significant direct, indirect, potential, and intangible costs, possibly increasing over time. Economic efforts directed at preventing occupational exposures and infections, including provision of safety-engineered devices, may be offset by the savings from a lower incidence of NSIs
    corecore