23 research outputs found

    Initial Steps Towards a Clinical FLASH Radiotherapy System: Pediatric Whole Brain Irradiation with 40 MeV Electrons at FLASH Dose Rates

    Get PDF
    In this work, we investigated the delivery of a clinically acceptable pediatric whole brain radiotherapy plan at FLASH dose rates using two lateral opposing 40-MeV electron beams produced by a practically realizable linear accelerator system. The EGSnrc Monte Carlo software modules, BEAMnrc and DOSXYZnrc, were used to generate whole brain radiotherapy plans for a pediatric patient using two lateral opposing 40-MeV electron beams. Electron beam phase space files were simulated using a model of a diverging beam with a diameter of 10 cm at 50 cm SAD (defined at brain midline). The electron beams were collimated using a 10-cm-thick block composed of 5 cm of aluminum oxide and 5 cm of tungsten. For comparison, a 6-MV photon plan was calculated with the Varian AAA algorithm. Electron beam parameters were based on a novel linear accelerator designed for the PHASER system and powered by a commercial 6-MW klystron. Calculations of the linear accelerator's performance indicated an average beam current of at least 6.25 µA, providing a dose rate of 115 Gy/s at isocenter, high enough for cognition-sparing FLASH effects. The electron plan was less homogenous with a homogeneity index of 0.133 compared to the photon plan's index of 0.087. Overall, the dosimetric characteristics of the 40-MeV electron plan were suitable for treatment. In conclusion, Monte Carlo simulations performed in this work indicate that two lateral opposing 40-MeV electron beams can be used for pediatric whole brain irradiation at FLASH dose rates of >115 Gy/s and serve as motivation for a practical clinical FLASH radiotherapy system, which can be implemented in the near future

    Predicting per-lesion local recurrence in locally advanced non-small cell lung cancer following definitive radiation therapy using pre- and mid-treatment metabolic tumor volume

    Get PDF
    Background: We evaluated whether pre- and mid-treatment metabolic tumor volume (MTV) predicts per lesion local recurrence (LR) in patients treated with definitive radiation therapy (RT, dose≥60 Gy) for locally advanced non-small cell lung cancer (NSCLC). Methods: We retrospectively reviewed records of patients with stage III NSCLC treated from 2006 to 2018 with pre- and mid-RT PET-CT. We measured the MTV of treated lesions on the pre-RT (MTVpre) and mid-RT (MTVmid) PET-CT. LR was defined per lesion as recurrence within the planning target volume. Receiver operating characteristic (ROC) curves, cumulative incidence rates, and uni- and multivariable (MVA) competing risk regressions were used to evaluate the association between MTV and LR. Results: We identified 111 patients with 387 lesions (112 lung tumors and 275 lymph nodes). Median age was 68 years, 69.4% were male, 46.8% had adenocarcinoma, 39.6% had squamous cell carcinoma, and 95.5% received concurrent chemotherapy. Median follow-up was 38.7 months. 3-year overall survival was 42.3%. 3-year cumulative incidence of LR was 26.8% per patient and 11.9% per lesion. Both MTVpre and MTVmid were predictive of LR by ROC (AUC = 0.71 and 0.76, respectively) and were significantly associated with LR on MVA (P = 0.004 and P = 7.1e-5, respectively). Among lesions at lower risk of LR based on MTVpre, higher MTVmid was associated with LR (P = 0.001). Conclusion: Per-lesion, larger MTVpre and MTVmid predicted for increased risk of LR. MTVmid was more highly predictive of LR than MTVpre and if validated may allow for further discrimination of high-risk lesions at mid-RT informing dose painting strategies

    Induction EGFR tyrosine kinase inhibitors prior to definitive chemoradiotherapy in unresectable stage III EGFR-mutated non-small cell lung cancer

    Get PDF
    INTRODUCTION: Increasing evidence suggests that consolidation durvalumab confers limited benefits for patients with stage III EGFR-mutated NSCLC. Induction or maintenance EGFR tyrosine kinase inhibitors (TKIs) added to concurrent chemoradiotherapy (CRT) may optimize definitive treatment, but there are limited data supporting an induction TKI strategy. METHODS: We evaluated the efficacy and safety of induction EGFR TKIs administered before concurrent CRT in a retrospective series of patients with unresectable locally advanced EGFR-mutated NSCLC. Circulating tumor DNA (ctDNA) analysis was performed on a patient subset using CAPP-seq and correlated with outcomes. RESULTS: Of six patients, three received erlotinib and three osimertinib as induction therapy before CRT. Induction TKIs were administered for a median of 2.5 months. The objective response rate after induction TKI was 83%. One patient had a complete response to induction erlotinib and continued erlotinib for 4 years until local progression, which was treated with CRT. Two patients completed maintenance erlotinib after CRT, and another received consolidation durvalumab. After a median follow-up of 20.5 months, only one patient developed disease recurrence, with rising ctDNA coinciding with recurrence. ctDNA remained undetectable in patients without recurrence, or low-level in a patient receiving maintenance erlotinib. Adverse events were mild and expected, and none developed pneumonitis. CONCLUSION: Induction EGFR TKI before CRT may achieve high disease control rates with promising signs of durability in patients with locally advanced EGFR-mutated NSCLC. ctDNA analysis after CRT can correlate well with clinical outcomes. Prospective studies are needed to define the role of induction EGFR TKIs in this setting

    Evaluating the Reproducibility of Mouse Anatomy under Rotation in a Custom Immobilization Device for Conformal FLASH Radiotherapy

    Get PDF
    The observation of an enhanced therapeutic index for FLASH radiotherapy in mice has created interest in practical laboratory-based FLASH irradiators. To date, systems capable of 3D conformal FLASH irradiation in mice have been lacking. We are developing such a system, incorporating a high-current linear accelerator to produce a collimated X-ray beam in a stationary beamline design, rotating the mouse about a longitudinal axis to achieve conformal irradiation from multiple beam directions. The purpose of this work was to evaluate the reproducibility of mouse anatomy under rotation at speeds compatible with conformal FLASH delivery. Three short-hair mice and two hairless mice were immobilized under anesthesia in body weight-specific contoured plastic molds, and subjected to three rotational (up to 3 revolutions/s) and two non-rotational movement interventions. MicroCT images were acquired before and after each intervention. The displacements of 11 anatomic landmarks were measured on the image pairs. The displacement of the anatomical landmarks with any of the interventions was 0.5 mm or less for 92.4% of measurements, with a single measurement out of 275 (11 landmarks × 5 interventions × 5 mice) reaching 1 mm. There was no significant difference in the displacements associated with rotation compared to those associated with moving the immobilized mouse in and out of a scanner or with leaving the mouse in place for 5 min with no motion. There were no significant differences in displacements between mice with or without hair, although the analysis is limited by small numbers, or between different anatomic landmarks. These results show that anatomic reproducibility under rotation speed corresponding to FLASH irradiation times appears to be compatible with conformal/stereotactic irradiation in mice

    Reduced cognitive deficits after FLASH irradiation of whole mouse brain are associated with less hippocampal dendritic spine loss and neuroinflammation

    Get PDF
    Aim To evaluate the impact of ultra-rapid FLASH mouse whole brain irradiation on hippocampal dendritic spines and neuroinflammation, factors associated with cognitive impairment after brain irradiation. Methods We administered 30 Gy whole brain irradiation to C57BL6/J mice in sub-second (FLASH) vs. 240 s conventional delivery time keeping all other parameters constant, using a custom configured clinical linac. Ten weeks post-irradiation, we evaluated spatial and non-spatial object recognition using novel object location and object recognition testing. We measured dendritic spine density by tracing Golgi-stained hippocampal neurons and evaluated neuroinflammation by CD68 immunostaining, a marker of activated microglia, and expression of 10 pro-inflammatory cytokines using a multiplex immunoassay. Results At ten weeks post-irradiation, compared to unirradiated controls, conventional delivery time irradiation significantly impaired novel object location and recognition tasks whereas the same dose given in FLASH delivery did not. Conventional delivery time, but not FLASH, was associated with significant loss of dendritic spine density in hippocampal apical dendrites, with a similar non-significant trend in basal dendrites. Conventional delivery time was associated with significantly increased CD68-positive microglia compared to controls whereas FLASH was not. Conventional delivery time was associated with significant increases in 5 of 10 pro-inflammatory cytokines in the hippocampus (and non-significant increases in another 3), whereas FLASH was associated with smaller increases in only 3. Conclusion Reduced cognitive impairment and associated neurodegeneration were observed with FLASH compared to conventional delivery time irradiation, potentially through decreased induction of neuroinflammation, suggesting a promising approach to increasing therapeutic index in radiation therapy of brain tumors

    Impact of Audiovisual-Assisted Therapeutic Ambience in Radiation Therapy (AVATAR) on Anesthesia Use, Payer Charges, and Treatment Time in Pediatric Patients

    Get PDF
    Purpose Pediatric radiation therapy (RT) requires optimal immobilization that often necessitates daily anesthesia. To decrease anesthesia use, we implemented a novel audiovisual-assisted therapeutic ambience in RT (AVATAR) system that projects video onto a radiolucent screen within the child’s line of vision to provide attentional diversion. We investigated its reduction on anesthesia use, payer charges, and treatment time, in addition to its impact on radiation delivery. Methods and Materials A 6-year retrospective analysis was performed among children undergoing RT (n = 224) 3 years before and 3 years after the introduction of AVATAR. The frequency of anesthesia use before and after AVATAR implementation, in addition to RT treatment times, were compared. The number of spared anesthesia treatments allowed for a charge to payer analysis. To document the lack of surface dose perturbation by AVATAR, a phantom craniospinal treatment course was delivered both with and without AVATAR. Additionally, an ion chamber course was delivered to document changes to the dose at depth. Results More children were able to avoid anesthesia use entirely in the post-AVATAR cohort compared with the pre-AVATAR cohort (73.2% vs 63.4%; P = .03), and fewer required anesthesia for each treatment (18.8% vs 33%; P = .03). AVATAR introduction reduced anesthesia use for all ages studied. Treatment time per session was reduced by 38% using AVATAR compared with anesthesia. There were 326 fewer anesthesia sessions delivered over 3 years after AVATAR was introduced, with an estimated savings of >500,000.Opticallystimulatedluminescentdosimetersrevealedasmallincreaseindoseof0.8ConclusionsAVATARintroductiondecreasedanesthesiauseinchildrenundergoingRT.Morechildrenavoidedanesthesiaentirely,andfewerneededanesthesiaforeverytreatment,resultinginareductionintreatmenttimeandsavingsofnearly500,000. Optically stimulated luminescent dosimeters revealed a small increase in dose of 0.8% to 9.5% with AVATAR, whereas the use of a thermomolded face mask increased skin dose by as much as 58%. Conclusions AVATAR introduction decreased anesthesia use in children undergoing RT. More children avoided anesthesia entirely, and fewer needed anesthesia for every treatment, resulting in a reduction in treatment time and savings of nearly 550,000 in approximately 3 years, with minimal perturbation of RT dose delivery

    FLASH Irradiation Results in Reduced Severe Skin Toxicity Compared to Conventional-Dose-Rate Irradiation

    Get PDF
    Radiation therapy, along with surgery and chemotherapy, is one of the main treatments for cancer. While radiotherapy is highly effective in the treatment of localized tumors, its main limitation is its toxicity to normal tissue. Previous preclinical studies have reported that ultra-high dose-rate (FLASH) irradiation results in reduced toxicity to normal tissues while controlling tumor growth to a similar extent relative to conventional-dose-rate (CONV) irradiation. To our knowledge this is the first report of a dose-response study in mice comparing the effect of FLASH irradiation vs. CONV irradiation on skin toxicity. We found that FLASH irradiation results in both a lower incidence and lower severity of skin ulceration than CONV irradiation 8 weeks after single-fraction hemithoracic irradiation at high doses (30 and 40 Gy). Survival was also higher after FLASH hemithoracic irradiation (median survival >180 days at doses of 30 and 40 Gy) compared to CONV irradiation (median survival 100 and 52 days at 30 and 40 Gy, respectively). No ulceration was observed at doses 20 Gy or below in either FLASH or CONV. These results suggest a shifting of the dose-response curve for radiation-induced skin ulceration to the right for FLASH, compared to CONV irradiation, suggesting the potential for an enhanced therapeutic index for radiation therapy of cancer

    The properties of proton-proton interactions between 100 and 1000 GeV from a cosmic-ray experiment

    Full text link
    Proton-proton interactions above 100 GeV have been studied in an experiment using cosmic-ray protons interacting in a liquid hydrogen target. From several hundred hydrogen interactions, it has been learned that: (a) the total inelastic pp cross section is not changing significantly with energy above 30 GeV; (b) the multiplicity distributions of charged prongs agree with a Poisson distribution in charged-particle pairs; (c) the average charged prong multiplicity increases as 1 n s; (d) the angular distribution of charged particles agrees with a c.m. momentum distribution of charged particles that varies as exp exp [-8 pT2-8x2] d3p/E (where X = pL/po) and a nucleon distribution that varies as 10x exp [-3 pT2] d3p/E for 0.05 < x < 0.85. Further properties of the angular distributions, characteristics of the ionization calorimeter, the cross section in iron, and other features of the data are reported.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/34084/1/0000363.pd

    Abdominal FLASH irradiation reduces radiation-induced gastrointestinal toxicity for the treatment of ovarian cancer in mice

    Get PDF
    Radiation therapy is the most effective cytotoxic therapy for localized tumors. However, normal tissue toxicity limits the radiation dose and the curative potential of radiation therapy when treating larger target volumes. In particular, the highly radiosensitive intestine limits the use of radiation for patients with intra-abdominal tumors. In metastatic ovarian cancer, total abdominal irradiation (TAI) was used as an effective postsurgical adjuvant therapy in the management of abdominal metastases. However, TAI fell out of favor due to high toxicity of the intestine. Here we utilized an innovative preclinical irradiation platform to compare the safety and efficacy of TAI ultra-high dose rate FLASH irradiation to conventional dose rate (CONV) irradiation in mice. We demonstrate that single high dose TAI-FLASH produced less mortality from gastrointestinal syndrome, spared gut function and epithelial integrity, and spared cell death in crypt base columnar cells compared to TAI-CONV irradiation. Importantly, TAI-FLASH and TAI-CONV irradiation had similar efficacy in reducing tumor burden while improving intestinal function in a preclinical model of ovarian cancer metastasis. These findings suggest that FLASH irradiation may be an effective strategy to enhance the therapeutic index of abdominal radiotherapy, with potential application to metastatic ovarian cancer
    corecore