234 research outputs found

    Is Gly16Arg β<sub>2</sub> Receptor Polymorphism Related to Impulse Oscillometry in a Real-Life Asthma Clinic Setting?

    Get PDF
    PURPOSE: We evaluated whether Gly16Arg beta2-receptor genotype relates to impulse oscillometry (IOS) in a real-life clinic setting. METHODS: Patients with persistent asthma taking inhaled corticosteroid ± long-acting beta-agonist (ICS ± LABA) were evaluated. We compared genotype groups comprising either no Arg copies (i.e. GlyGly) versus one or two Arg copies (i.e. ArgArg or ArgGly). IOS outcomes included total airway resistance at 5 Hz (R5), central airway resistance at 20 Hz (R20), peripheral airway resistance (R5–R20), reactance at 5 Hz, area under reactance curve (AX) and resonant frequency (RF). In addition, we recorded ACQ-5 and salbutamol use. RESULTS: One hundred and twelve ICS-treated asthmatic patients (mean ICS dose 1238 µg/day), mean age 43 years, ACQ 2.34, FEV1 82 %, R5 177 % were identified—89 were also taking LABA. 61 patients were GlyGly, while 14 were ArgArg and 37 were ArgGly. There were no significant differences in IOS outcomes, ACQ or salbutamol use between the genotypes. The allelic risk (as odds ratio) for less well-controlled asthma (as ACQ > 1.5) was 1.1 (95 % CI 0.72–1.68) in relation to each Arg copy with a corresponding odds ratio for abnormal R5–R20 > 0.07kPA/l.s being 0.91 (95 % CI 0.57–1.44). 71 % of patients had an ACQ > 1.5 in the GlyGly group, versus 67 % in GlyArg/ArgArg group, with corresponding figures for abnormal R5–R20 > 0.07 kPa/l.s being 69 versus 73 %. CONCLUSION: In a real-life clinic setting for patients with poorly controlled persistent asthma taking ICS ± LABA, we found no evidence of any relationship of Gly16Arg to IOS, ACQ or salbutamol use

    Rates of asthma attacks in patients with previously inadequately controlled mild asthma treated in clinical practice with combination drug therapy: an exploratory post-hoc analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Differences could exist in the likelihood of asthma attacks in patients treated with inhaled corticosteroid (ICS), long-acting beta-agonist (LABA), and montelukast (MON) (ICS/LABA/MON) and patients treated with an inhaled corticosteroid (ICS) and montelukast (MON) (ICS/MON).</p> <p>Methods</p> <p>This was a post-hoc analysis of a pretest-posttest retrospective cohort study. Patients with mild persistent asthma and allergic rhinitis, who were taking an ICS either alone or in combination with a LABA, started concomitant MON treatment as part of their routine care. Rates of asthma- and allergic rhinitis-related medical resource use in the 12-months after the initial (index) MON prescription were compared in the ICS/MON and ICS/LABA/MON groups. An asthma attack was defined as an asthma-related hospitalization, ER visit, or use of an oral corticosteroid.</p> <p>Results</p> <p>Of the total of 344 patients, 181 (53%) received ICS/MON and 163 (47%) received ICS/LABA/MON in the post-index period for means of 10.5 and 11.4 months, respectively, (P < 0.05). Short-acting beta-agonists were used by 74.6% in the ICS/MON and 71.8% in the ICS/LABA/MON groups (P > 0.05). An asthma attack occurred in 4.4% of the ICS/MON group and 6.8% of the ICS/LABA/MON group (P > 0.05). The adjusted odds of an asthma attack in the post-index period in the ICS/LABA/MON group relative to the ICS/MON group was 1.24, 95% confidence interval 0.35–4.44.</p> <p>Conclusion</p> <p>In this observational study of combination drug treatment of mild persistent asthma and allergic rhinitis, no difference was observed between LABA/ICS/MON combination therapy and the ICS/MON combination without LABA use, for the rate of asthma attacks over one year.</p

    Significant receptor affinities of metabolites and a degradation product of mometasone furoate

    Get PDF
    Mometasone furoate (MF) is a highly potent glucocorticoid used topically to treat inflammation in the lung, nose and on the skin. However, so far no information has been published on the human glucocorticoid receptor activity of the metabolites or degradation products of MF. We have now determined the relative receptor binding affinities of the known metabolite 6β-OH MF and the degradation product 9,11-epoxy MF to understand their possible contribution to undesirable systemic side effects. In competition experiments with human lung glucocorticoid receptors we have determined the relative receptor affinities (RRA) of these substances with reference to dexamethasone (RRA = 100). We have discovered that 6β-OH MF and 9,11-epoxy MF display RRAs of 206 ± 15 and 220 ± 22, respectively. This level of activity is similar to that of the clinically used inhaled corticosteroid flunisolide (RRA 180 ± 11). Furthermore we observed that 9,11-epoxy MF is a chemically reactive metabolite. In recovery experiments with human plasma and lung tissue we found a time dependent decrease in extractability of the compound. Hence, we provide data that might contribute to the understanding of the pharmacokinetics as well as the clinical effects of MF

    Impact of inhaled corticosteroids on growth in children with asthma: systematic review and meta-analysis

    Get PDF
    Background: Long-term inhaled corticosteroids (ICS) may reduce growth velocity and final height of children with asthma. We aimed to evaluate the association between ICS use of >12 months and growth. Methods: We initially searched MEDLINE and EMBASE in July 2013, followed by a PubMed search updated to December 2014. We selected RCTs and controlled observational studies of ICS use in patients with asthma. We conducted random effects meta-analysis of mean differences in growth velocity (cm/year) or final height (cm) between groups. Heterogeneity was assessed using the I2 statistic. Results: We found 23 relevant studies (twenty RCTs and three observational studies) after screening 1882 hits. Meta-analysis of 16 RCTs showed that ICS use significantly reduced growth velocity at one year follow-up (mean difference -0.48 cm/year (95% CI -0.66 to -0.29)). There was evidence of a dose-response effect in three RCTs. Final adult height showed a mean reduction of -1.20 cm (95% CI -1.90 cm to -0.50 cm) with budesonide versus placebo in a high quality RCT. Meta-analysis of two lower quality observational studies revealed uncertainty in the association between ICS use and final adult height, pooled mean difference -0.85 cm (95% CI -3.35 to 1.65). Conclusion: Use of ICS for >12 months in children with asthma has a limited impact on annual growth velocity. In ICS users, there is a slight reduction of about a centimeter in final adult height, which when interpreted in the context of average adult height in England (175 cm for men and 161 cm for women), represents a 0.7% reduction compared to non-ICS users

    Quantifying the real life risk profile of inhaled corticosteroids in COPD by record linkage analysis

    Get PDF
    BACKGROUND: Inhaled corticosteroids (ICS), especially when prescribed in combination with long-acting β(2) agonists have been shown to improve COPD outcomes. Although there is consistent evidence linking ICS with adverse effects such as pneumonia, the complete risk profile is unclear with conflicting evidence on any association between ICS and the incidence or worsening of existing diabetes, cataracts and fractures. We investigated this using record linkage in a Dundee COPD population. METHODS: A record linkage study linking COPD and diabetes datasets with prescription, hospitalisation and mortality data via a unique Community Health Index (CHI) number. A Cox regression model was used to determine the association between ICS use and new diabetes or worsening of existing diabetes and hospitalisations for pneumonia, fractures or cataracts after adjusting for potential confounders. A time dependent analysis of exposure comparing time on versus off ICS was used to take into account patients changing their exposure status during follow-up and to prevent immortal time bias. RESULTS: 4305 subjects (3243 exposed to ICS, total of 17,229 person-years of exposure and 1062 non exposed, with a follow-up of 4,508 patient-years) were eligible for the study. There were 239 cases of new diabetes (DM) and 265 cases of worsening DM, 550 admissions for pneumonia, 288 hospitalisations for fracture and 505 cataract related admissions. The hazard ratio for the association between cumulative ICS and outcomes were 0.70 (0.43-1.12), 0.57 (0.24-1.37), 1.38 (1.09-1.74), 1.08 (0.73-1.59) and 1.42 (1.07-1.88) after multivariate analysis respectively. CONCLUSION: The use of ICS in our cohort was not associated with new onset of diabetes, worsening of existing diabetes or fracture hospitalisation. There was however an association with increased cataracts and pneumonia hospitalisations

    Efficacy and safety of indacaterol 150 μg once-daily in COPD: a double-blind, randomised, 12-week study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Indacaterol is a novel, once-daily (o.d.) inhaled, long-acting <it>β</it><sub>2</sub>-agonist in development for chronic obstructive pulmonary disease (COPD). This 12-week, double-blind study compared the efficacy, safety, and tolerability of indacaterol to that of placebo in patients with moderate-to-severe COPD.</p> <p>Methods</p> <p>Efficacy variables included 24-h trough FEV<sub>1 </sub>(mean of 23 h 10 min and 23 h 45 min post-dose) at Week 12 (primary endpoint) and after Day 1, and the percentage of COPD days with poor control (i.e., worsening symptoms). Safety was assessed by adverse events (AEs), mean serum potassium and blood glucose, QTc (Fridericia), and vital signs.</p> <p>Results</p> <p>Patients were randomised (n = 416, mean age 63 years) to receive either indacaterol 150 <it>μ</it>g o.d. (n = 211) or placebo (n = 205) via a single-dose dry-powder inhaler; 87.5% completed the study. Trough FEV<sub>1 </sub>(LSM ± SEM) at Week 12 was 1.48 ± 0.018 L for indacaterol and 1.35 ± 0.019 L for placebo, a clinically relevant difference of 130 ± 24 mL (p < 0.001). Trough FEV<sub>1 </sub>after one dose was significantly higher with indacaterol than placebo (p < 0.001). Indacaterol demonstrated significantly higher peak FEV<sub>1 </sub>than placebo, both on Day 1 and at Week 12, with indacaterol-placebo differences (LSM ± SEM) of 190 ± 28 (p < 0.001) and 160 ± 28 mL (p < 0.001), respectively. Standardised AUC measurements for FEV<sub>1 </sub>(between 5 min and 4 h, 5 min and 1 h, and 1 and 4 h post-dose) at Week 12 were all significantly greater with indacaterol than placebo (p < 0.001), with LSM (± SEM) differences of 170 ± 24, 180 ± 24, and 170 ± 24 mL, respectively. Indacaterol significantly reduced the percentage of days of poor control versus placebo by 22.5% (p < 0.001) and was also associated with significantly reduced use of rescue medication (p < 0.001). The overall rates of AEs were comparable between the groups (indacaterol 49.3%, placebo 46.8%), with the most common AEs being COPD worsening (indacaterol 8.5%, placebo 12.2%) and cough (indacaterol 6.2%, placebo 7.3%). One patient died in the placebo group. Serum potassium and blood glucose levels did not differ significantly between the two groups, and no patient had QTc >500 ms.</p> <p>Conclusions</p> <p>Indacaterol 150 <it>μ</it>g o.d. provided clinically significant and sustained bronchodilation, reduced rescue medication use, and had a safety and tolerability profile similar to placebo.</p> <p>Trial registration</p> <p>NCT00624286</p

    Effect of a 14-day course of systemic corticosteroids on the hypothalamic-pituitary-adrenal-axis in patients with acute exacerbation of chronic obstructive pulmonary disease

    Get PDF
    <p/> <p>Background</p> <p>As supra-physiological intake of corticosteroids is a well known risk factor for the development of adrenal insufficiency, we investigated the function of the hypothalamic-pituitary-adrenal (HPA) axis during a 14-day course of systemic corticosteroids in patients with acute exacerbation of chronic obstructive pulmonary disease using clinical and laboratory measures.</p> <p>Methods</p> <p>A systematic clinical and laboratory assessment including measurement of basal cortisol levels and the response to low dose (1 μg) ACTH stimulation was performed in nine patients before, on the first and the last day of treatment, as well as 2, 7 and 21 days after corticosteroid withdrawal.</p> <p>Results</p> <p>At baseline, all nine patients had normal responses to 1 μg ACTH. On the first day of steroid treatment, 78% had a blunted peak cortisol response. This percentage increased to 89% after 14 days of steroid treatment. 78%, 33% and 33% of the patients had a blunted cortisol response to ACTH 2, 7, and 21 days after corticosteroid withdrawal, respectively. ROC curve analysis revealed that only basal cortisol concentrations (AUC 0.89), but not ACTH concentrations (AUC 0.49) or clinical signs (AUC 0.47) were predictive of an impaired function of the HPA axis. Basal cortisol levels of > 400 and < 150 nmol/l were 96% and 100% sensitive for a normal or pathological response to the ACTH stimulation test, respectively.</p> <p>Conclusion</p> <p>Immediate and prolonged suppression of the HPA axis is a common finding in otherwise asymptomatic patients undergoing systemic steroid treatment for acute exacerbation of chronic obstructive pulmonary disease and can reliably be assessed with the low-dose ACTH test.</p
    • …
    corecore