199 research outputs found

    MOD-0A 200 kW wind turbine generator design and analysis report

    Get PDF
    The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments. The project requirements, approach, system description, design requirements, design, analysis, system tests, installation, safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the wind turbine are discussed. The design and analysis of the rotor, drive train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electricl system, and control systems are presented. The rotor includes the blades, hub, and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control are discussed. Systems analyses on dynamic loads and fatigue are presented

    The MOD-OA 200 kilowatt wind turbine generator design and analysis report

    Get PDF
    The project requirements, approach, system description, design requirements, design, analysis, system tests, installation safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the MOD-OA 200 kw wind turbine generator are discussed. The components, the rotor, driven train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electrical system, and control systems are presented. The rotor includes the blades, hub and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control and Dynamic loads and fatigue are analyzed

    Differentially Private Billing with Rebates

    Get PDF
    A number of established and novel business models are based on fine grained billing, including pay-per-view, mobile messaging, voice calls, pay-as-you-drive insurance, smart metering for utility provision, private computing clouds and hosted services. These models apply fine-grained tariffs dependent on time-of-use or place of-use to readings to compute a bill. We extend previously proposed billing protocols to strengthen their privacy in two key ways. First, we study the monetary amount a customer should add to their bill in order to provably hide their activities, within the differential privacy framework. Second, we propose a cryptographic protocol for oblivious billing that ensures any additional expenditure, aimed at protecting privacy, can be tracked and reclaimed in the future, thus minimising its cost. Our proposals can be used together or separately and are backed by provable guarantees of security. © 2011 Springer-Verlag

    Considerations for Management of Longitudinal Melanonychia During the COVID-19 Pandemic: An International Perspective

    Get PDF
    To the editor: 34 Longitudinal melanonychia (LM) is the presenting sign of nail unit melanoma (NUM) in 2/3 35 of cases and is therefore among the most important conditions managed by dermatologists. In 36 normal times, referral for LM would prompt an expedited appointment for clinical 37 examination and dermoscopy.1 However, due to SARS-CoV-2, dermatologists have been 38 asked to reconsider “urgent/emergency” conditions. The COVID-19 pandemic has propelled 39 physicians to unexpectedly adopt telemedicine without adequate guidance for managing LM 40 patients

    A Four-Antigen Mixture for Rapid Assessment of Onchocerca volvulus Infection

    Get PDF
    Caused by the filarial parasite Onchocerca volvulus, onchocerciasis is a neglected tropical disease associated with blindness and severe dermatitis. Available diagnostic methods are either invasive, require hours or days to perform, and/or need sophisticated equipment to be conducted. Thus, there is an urgent need for simple and rapid technologies for the specific diagnosis of Onchocerca volvulus infection. Here we investigated whether luciferase immunoprecipitation systems (LIPS) can produce a more rapid and specific test for diagnosis of O. volvulus infection. Using modified versions of previously identified Onchocerca-specific antigens, LIPS tests detected antibodies to all four O. volvulus antigens and easily distinguished the O. volvulus-infected samples from uninfected samples. We also tested these four different antigens in a simpler format as a combined mixture and distinguished 100% of the confirmed cases from the uninfected controls. A rapid 15-minute version of this mixture test (QLIPS) also allowed distinction of 100% of the cases from those uninfected and performed even better in identifying Onchocerca from other cross-reactive parasitic infections. This study suggests that this rapid LIPS test (QLIPS) has the potential to be used in point-of-care detection of onchocerciasis and thereby may provide a new tool for diagnosis and the monitoring of transmission control measures

    Filariasis in Travelers Presenting to the GeoSentinel Surveillance Network

    Get PDF
    As international travel increases, there is rising exposure to many pathogens not traditionally encountered in the resource-rich countries of the world. The GeoSentinel Surveillance Network, a global network of medicine/travel clinics, was established in 1995 to detect morbidity trends among travelers. Filarial infections (parasitic worm infections that cause, among others, onchocerciasis [river blindness], lymphatic filariasis [e.g. elephantiasis, lymphedema, hydrocele] and loiasis [African eyeworm]) comprised 0.62% (n = 271) of the 43,722 medical conditions reported to the GeoSentinel Network between 1995 and 2004. Immigrants from filarial-endemic regions comprised the group most likely to have acquired a filarial infection; sub-Saharan Africa was the region of the world where the majority of filarial infections were acquired. Long-term travel (greater than 1 month) was more likely to be associated with acquisition of one of the filarial infections than shorter-term travel
    corecore