29 research outputs found

    Concepts, protocol, variations and current trends in surgery first orthognathic approach: A literature review

    Get PDF
    In the current era of expedited orthodontics, among many clinicians, tertiary care hospitals and patients, surgery first orthognathic approach (SFOA) has gained popularity. The advantages of SFOA (face first approach) are the reduced overall treatment duration and the early improvement in facial esthetics. In SFOA, the absence of a presurgical phase allows surgery to be performed first, followed by comprehensive orthodontic treatment to achieve the desired occlusion. The basic concepts of surgery early, surgery last, SFOA and Sendai SFOA technique along with its variations are reviewed in the present article. The recent advancement in SFOA in the context of preoperative preparation, surgical procedures and post-surgical orthodontics with pertinent literature survey are also discussed

    Traffic-Related Air Pollution and DNA Damage: A Longitudinal Study in Taiwanese Traffic Conductors

    Get PDF
    BACKGROUND: There is accumulating epidemiologic evidence that exposure to traffic-related air pollutants, including particulate matter (PM) and polyaromatic hydro carbons (PAHs), plays a role in etiology and prognosis of a large scale of illnesses, although the role of specific causal agents and underlying mechanisms for different health outcomes remains unknown. OBJECTIVE: Our general objective was to assess the relations between personal exposure to traffic exhausts, in particular ambient PM(2.5) and PAHs, and the occurrence of DNA strand breaks by applying personal monitoring of PM and biomarkers of exposure (urinary 1-hydroxypyrene-glucuronide, 1-OHPG) and effect (urinary 8-hydroxydeoxyguanosine, 8-OHdG and DNA strand breaks). METHODS: We recruited 91 traffic conductors and 53 indoor office workers between May 2009 and June 2011 in Taipei City, Taiwan. We used PM(2.5) personal samplers to collect breathing-zone particulate PAHs samples. Spot urine and blood samples after work shift of 2 consecutive days were analyzed for 1-OHPG, 8-OHdG and DNA strand breaks, respectively. Statistical methods included linear regression and mixed models. RESULTS: Urinary 8-OHdG levels and the occurrence of DNA strand breaks in traffic conductors significantly exceeded those in indoor office workers in mixed models. Particulate PAHs levels showed a positive association with urinary 1-OHPG in the regression model (β = 0.056, p = 0.01). Urinary 1-OHPG levels were significantly associated with urinary 8-OHdG levels in the mixed model (β = 0.101, p = 0.023). Our results provide evidence that exposure to fine particulates causes DNA damage. Further, particulate PAHs could be biologically active constituents of PM(2.5) with reference to the induction of oxidative DNA damages

    Transfer Function Analysis of Respiratory and Cardiac Pulsations in Human Brain Observed on Dynamic Magnetic Resonance Images

    Get PDF
    Magnetic resonance (MR) imaging provides a noninvasive, in vivo imaging technique for studying respiratory and cardiac pulsations in human brains, because these pulsations can be recorded as flow-related enhancement on dynamic MR images. By applying independent component analysis to dynamic MR images, respiratory and cardiac pulsations were observed. Using the signal-time curves of these pulsations as reference functions, the magnitude and phase of the transfer function were calculated on a pixel-by-pixel basis. The calculated magnitude and phase represented the amplitude change and temporal delay at each pixel as compared with the reference functions. In the transfer function analysis, near constant phases were found at the respiratory and cardiac frequency bands, indicating the existence of phase delay relative to the reference functions. In analyzing the dynamic MR images using the transfer function analysis, we found the following: (1) a good delineation of temporal delay of these pulsations can be achieved; (2) respiratory pulsation exists in the ventricular and cortical cerebrospinal fluid; (3) cardiac pulsation exists in the ventricular cerebrospinal fluid and intracranial vessels; and (4) a 180-degree phase delay or inverted amplitude is observed on phase images
    corecore