234 research outputs found

    Determining the effects of cattle grazing treatments on Yosemite toads (Anaxyrus [=Bufo] canorus) in montane meadows.

    Get PDF
    Amphibians are experiencing a precipitous global decline, and population stability on public lands with multiple uses is a key concern for managers. In the Sierra Nevada Mountains (California, USA), managers have specifically identified livestock grazing as an activity that may negatively affect Yosemite toads due to the potential overlap of grazing with toad habitat. Grazing exclusion from Yosemite toad breeding and rearing areas and/or entire meadows have been proposed as possible management actions to alleviate the possible impact of cattle on this species. The primary objective of this study was to determine if different fencing treatments affect Yosemite toad populations. We specifically examined the effect of three fencing treatments on Yosemite toad breeding pool occupancy, tadpoles, and young of the year (YOY). Our hypothesis was that over the course of treatment implementation (2006 through 2010), Yosemite toad breeding pool occupancy and early life stage densities would increase within two fencing treatments relative to actively grazed meadows due to beneficial changes to habitat quality in the absence of grazing. Our results did not support our hypothesis, and showed no benefit to Yosemite toad presence or early life stages in fenced or partially fenced meadows compared to standard USDA Forest Service grazing levels. We found substantial Yosemite toad variation by both meadow and year. This variation was influenced by meadow wetness, with water table depth significant in both the tadpole and YOY models

    Virtual Reality for Pain and Anxiety Management in Cardiac Surgery and Interventional Cardiology

    Get PDF
    Pain and anxiety are common in patients undergoing cardiac surgery and percutaneous cardiac interventions. Virtual reality (VR) is an emerging non-pharmacological tool for pain and anxiety management. However, its application around cardiac procedures remains relatively unexplored. In this review, we perform a targeted non-systematic literature review to assess the current state-of-the-art of VR for pain and anxiety management in patients undergoing cardiac procedures. Contexts of interest were preprocedural, periprocedural, and postprocedural applications. Existing trials show inconsistent results. The majority of studies in the preprocedural (7 studies, n = 302), periprocedural (1 study, n = 99), and postprocedural stage (4 studies, n = 214) demonstrate significant reduction of pain and anxiety through VR distraction therapy or VR patient education. However, larger-scale trials (2 preprocedural studies [n = 233], 1 periprocedural study [n = 32], 2 postprocedural studies [n = 300]) report no effect. Current literature on effectiveness of VR for pain and anxiety management in cardiac surgery and interventional cardiology remains inconclusive.</p

    Virtual Reality for Pain and Anxiety Management in Cardiac Surgery and Interventional Cardiology

    Get PDF
    Pain and anxiety are common in patients undergoing cardiac surgery and percutaneous cardiac interventions. Virtual reality (VR) is an emerging non-pharmacological tool for pain and anxiety management. However, its application around cardiac procedures remains relatively unexplored. In this review, we perform a targeted non-systematic literature review to assess the current state-of-the-art of VR for pain and anxiety management in patients undergoing cardiac procedures. Contexts of interest were preprocedural, periprocedural, and postprocedural applications. Existing trials show inconsistent results. The majority of studies in the preprocedural (7 studies, n = 302), periprocedural (1 study, n = 99), and postprocedural stage (4 studies, n = 214) demonstrate significant reduction of pain and anxiety through VR distraction therapy or VR patient education. However, larger-scale trials (2 preprocedural studies [n = 233], 1 periprocedural study [n = 32], 2 postprocedural studies [n = 300]) report no effect. Current literature on effectiveness of VR for pain and anxiety management in cardiac surgery and interventional cardiology remains inconclusive.</p

    Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients

    Get PDF
    INTRODUCTION: To obtain strict glucose regulation, an accurate and feasible bedside glucometry method is essential. We evaluated three different types of point-of-care glucometry in seriously ill intensive care unit (ICU) patients. The study was performed as a single-centre, prospective, observational study in a 12-bed medical ICU of a university hospital. METHODS: Patients with an expected ICU stay of more than 48 hours were included. Because the reference laboratory delivers glucose values after approximately 30 to 60 minutes, which is too slow to use in a glucose regulation protocol and for calibration of the subcutaneous continuous glucose monitoring system (CGMS) (CGMS System Gold), we first validated the ICU-based blood gas/glucose analyser ABL715 (part 1 of the study). Subsequently, part 2 was performed: after inserting (and calibrating) the subcutaneous CGMS, heparinised arterial blood samples were drawn from an arterial line every 6 hours and analysed on both the Precision PCx point-of-care meter using test strips and on the blood gas/glucose analyser ABL715. CGMS glucose data were downloaded after 24 to 72 hours. The results of the paired measurements were analysed as a scatter plot by the method of Bland and Altman and were expressed as a correlation coefficient. RESULTS: Part 1: Four hundred and twenty-four blood samples were drawn from 45 critically ill ICU patients. The ICU-based blood gas/glucose analyser ABL715 provided a good estimate of conventional laboratory glucose assessment: the correlation coefficient was 0.95. In the Clarke error grid, 96.8% of the paired measurements were in the clinically acceptable zones A and B. Part 2: One hundred sixty-five paired samples were drawn from 19 ICU patients. The Precision PCx point-of-care meter showed a correlation coefficient of 0.89. Ninety-eight point seven percent of measurements were within zones A and B. The correlation coefficient for the subcutaneous CGMS System Gold was 0.89. One hundred percent of measurements were within zones A and B. CONCLUSION: The ICU-based blood glucose analyser ABL715 is a rapid and accurate alternative for laboratory glucose determination and can serve as a standard for ICU blood glucose measurements. The Precision PCx is a good alternative, but feasibility may be limited because of the blood sample handling. The subcutaneous CGMS System Gold is promising, but real-time glucose level reporting is necessary before it can be of clinical use in the ICU. When implementing a glucose-insulin algorithm in patient care or research, one should realise that the absolute glucose level may differ systematically among various measuring methods, influencing targeted glucose levels

    Mutation of a nicotinic acetylcholine receptor β subunit is associated with resistance to neonicotinoid insecticides in the aphid Myzus persicae

    Get PDF
    This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly citedBackground: Myzus persicae is a globally important aphid pest with a history of developing resistance to insecticides. Unusually, neonicotinoids have remained highly effective as control agents despite nearly two decades of steadily increasing use. In this study, a clone of M. persicae collected from southern France was found, for the first time, to exhibit sufficiently strong resistance to result in loss of the field effectiveness of neonicotinoids. Results: Bioassays, metabolism and gene expression studies implied the presence of two resistance mechanisms in the resistant clone, one based on enhanced detoxification by cytochrome P450 monooxygenases, and another unaffected by a synergist that inhibits detoxifying enzymes. Binding of radiolabeled imidacloprid (a neonicotinoid) to whole body membrane preparations showed that the high affinity [3H]-imidacloprid binding site present in susceptible M. persicae is lost in the resistant clone and the remaining lower affinity site is altered compared to susceptible clones. This confers a significant overall reduction in binding affinity to the neonicotinoid target: the nicotinic acetylcholine receptor (nAChR). Comparison of the nucleotide sequence of six nAChR subunit (Mp alpha 1-5 and Mp beta 1) genes from resistant and susceptible aphid clones revealed a single point mutation in the loop D region of the nAChR beta 1 subunit of the resistant clone, causing an arginine to threonine substitution (R81T). Conclusion: Previous studies have shown that the amino acid at this position within loop D is a key determinant of neonicotinoid binding to nAChRs and this amino acid change confers a vertebrate-like character to the insect nAChR receptor and results in reduced sensitivity to neonicotinoids. The discovery of the mutation at this position and its association with the reduced affinity of the nAChR for imidacloprid is the first example of field-evolved target-site resistance to neonicotinoid insecticides and also provides further validation of exisiting models of neonicotinoid binding and selectivity for insect nAChRs.Peer reviewedFinal Published versio

    The K2-HERMES Survey: Age and Metallicity of the Thick Disc

    Get PDF
    Asteroseismology is a promising tool to study Galactic structure and evolution because it can probe the ages of stars. Earlier attempts comparing seismic data from the {\it Kepler} satellite with predictions from Galaxy models found that the models predicted more low-mass stars compared to the observed distribution of masses. It was unclear if the mismatch was due to inaccuracies in the Galactic models, or the unknown aspects of the selection function of the stars. Using new data from the K2 mission, which has a well-defined selection function, we find that an old metal-poor thick disc, as used in previous Galactic models, is incompatible with the asteroseismic information. We show that spectroscopic measurements of [Fe/H] and [α\alpha/Fe] elemental abundances from the GALAH survey indicate a mean metallicity of log(Z/Z)=0.16\log (Z/Z_{\odot})=-0.16 for the thick disc. Here ZZ is the effective solar-scaled metallicity, which is a function of [Fe/H] and [α\alpha/Fe]. With the revised disc metallicities, for the first time, the theoretically predicted distribution of seismic masses show excellent agreement with the observed distribution of masses. This provides an indirect verification of the asteroseismic mass scaling relation is good to within five percent. Using an importance-sampling framework that takes the selection function into account, we fit a population synthesis model of the Galaxy to the observed seismic and spectroscopic data. Assuming the asteroseismic scaling relations are correct, we estimate the mean age of the thick disc to be about 10 Gyr, in agreement with the traditional idea of an old α\alpha-enhanced thick disc.Comment: 21 pages, submitted to MNRA

    The GALAH Survey: Chemical Clocks

    Full text link
    Previous studies have found that the elemental abundances of a star correlate directly with its age and metallicity. Using this knowledge, we derive ages for a sample of 250,000 stars taken from GALAH DR3 using only their overall metallicity and chemical abundances. Stellar ages are estimated via the machine learning algorithm XGBoostXGBoost, using main sequence turnoff stars with precise ages as our input training set. We find that the stellar ages for the bulk of the GALAH DR3 sample are accurate to 1-2 Gyr using this method. With these ages, we replicate many recent results on the age-kinematic trends of the nearby disk, including the age-velocity dispersion relationship of the solar neighborhood and the larger global velocity dispersion relations of the disk found using GaiaGaia and GALAH. The fact that chemical abundances alone can be used to determine a reliable age for a star have profound implications for the future study of the Galaxy as well as upcoming spectroscopic surveys. These results show that the chemical abundance variation at a given birth radius is quite small, and imply that strong chemical tagging of stars directly to birth clusters may prove difficult with our current elemental abundance precision. Our results highlight the need of spectroscopic surveys to deliver precision abundances for as many nucleosynthetic production sites as possible in order to estimate reliable ages for stars directly from their chemical abundances. Applying the methods outlined in this paper opens a new door into studies of the kinematic structure and evolution of the disk, as ages may potentially be estimated for a large fraction of stars in existing spectroscopic surveys. This would yield a sample of millions of stars with reliable age determinations, and allow precise constraints to be put on various kinematic processes in the disk, such as the efficiency and timescales of radial migration.Comment: 13 pages, 15 figures, submitted to MNRA

    Maternal Plasma 25-Hydroxyvitamin D Concentrations and the Risk for Gestational Diabetes Mellitus

    Get PDF
    Background: Evidence is accumulating for a role of vitamin D in maintaining normal glucose homeostasis. However, studies that prospectively examined circulating concentrations of 25-hydroxyvitamin D (25-[OH] D) in relation to diabetes risk are limited. Our objective is to determine the association between maternal plasma 25-[OH] D concentrations in early pregnancy and the risk for gestational diabetes mellitus (GDM). Methods: A nested case-control study was conducted among a prospective cohort of 953 pregnant women. Among them, 57 incident GDM cases were ascertained and 114 women who were not diagnosed with GDM were selected as controls. Controls were frequency matched to cases for the estimated season of conception of the index pregnancy. Results: Among women who developed GDM, maternal plasma 25-[OH] D concentrations at an average of 16 weeks of gestation were significantly lower than controls (24.2 vs. 30.1 ng/ml, P<0.001). This difference remained significant (3.62 ng/ml lower on average in GDM cases than controls (P value = 0.018)) after the adjustment for maternal age, race, family history of diabetes, and pre-pregnancy BMI. Approximately 33% of GDM cases, compared with 14% of controls (P<0.001), had maternal plasma 25-[OH] D concentrations consistent with a pre-specified diagnosis of vitamin D deficiency (<20 ng/ml). After adjustment for the aforementioned covariates including BMI, vitamin D deficiency was associated with a 2.66-fold (OR (95% CI): 2.66 (1.01–7.02)) increased GDM risk. Moreover, each 5 ng/ml decrease in 25-[OH] D concentrations was related to a 1.29-fold increase in GDM risk (OR (95% CI): 1.29 (1.05–1.60)). Additional adjustment for season and physical activity did not change findings substantially. Conclusions: Findings from the present study suggest that maternal vitamin D deficiency in early pregnancy is significantly associated with an elevated risk for GDM
    corecore