695 research outputs found
Getting to know Pepper : Effects of people’s awareness of a robot’s capabilities on their trust in the robot
© 2018 Association for Computing MachineryThis work investigates how human awareness about a social robot’s capabilities is related to trusting this robot to handle different tasks. We present a user study that relates knowledge on different quality levels to participant’s ratings of trust. Secondary school pupils were asked to rate their trust in the robot after three types of exposures: a video demonstration, a live interaction, and a programming task. The study revealed that the pupils’ trust is positively affected across different domains after each session, indicating that human users trust a robot more the more awareness about the robot they have
Wide-Angle X-Band Antenna Array with Novel Radiating Elements
An antenna array with wide-angle beam steering is presented in this paper. The antenna consists of dielectrically filled open-ended waveguides with a new type of excitation as individual radiators. The characteristics of the radiator have been analyzed. The novel radiator has a wide beamwidth and the frequency band of around 21%. Following the computational modeling and experimental investigations the characteristics of the antenna array for scan angles up to 50° are discussed
Size dependence of photocatalytic oxidation reactions of Rh nanoparticles dispersed on (Ga1-xZnx)(N1-xOx) support
Mixed Ga–Zn oxynitrides were synthesized using coprecipitation, wet-precipitation, and solid-solution methods. The oxynitrides were used as supports for Rh nanoparticle catalysts in photocatalytic water splitting, CO oxidation, and H2 oxidation. Mixed Ga–Zn oxynitrides produced by wet precipitation and nitridation had good visible-light-absorption properties and high surface areas, so they were used to support uniformly sized poly(vinylpyrrolidone)-stabilized Rh nanoparticles. The nanoparticle size range was 2–9 nm. These catalysts had negligible activity in photocatalytic H2 production by water splitting with methanol as a sacrificial agent. Other mixed Ga–Zn oxynitrides were also inactive. A reference sample provided by Domen also showed very low activity. The influence of particle size on Rh-catalyzed oxidation of CO and H2 was investigated. For CO oxidation, the activities of small particles were higher for particles with higher Rh oxidation degrees. The opposite holds for H2 oxidation
Estimating non-response bias in family studies: application to mental health and lifestyle.
Non-response to mailed surveys reduces the effective sample size and may introduce bias. Non-response has been studied by (1) comparison to available data in population based registers, (2) directly contacting non-respondents by telephone or single-item reply cards, and (3) longitudinal repetition of the survey. The goal of this paper was to propose an additional method to study non-response bias: when the variable of interest has a familial component, data from respondents can be used as proxy for the data from their non-responding family members. This approach was used with data on smoking, alcohol consumption, physical activity, coffee- and tea-use, education, body mass index, religion, burnout, life events, personality and mental health in large number of siblings and DZ twins registered with the Netherlands Twin Register. In addition, for smoking behavior, we also used the second strategy by sending a reply card. Results show that scores of members from less cooperative families or incomplete twin pairs tended to be more unfavorable than the scores from highly cooperative families or complete twin pairs. For example, family members from less cooperative families cycled less often and scored higher on anxious depression and neuroticism. For smoking, both the results of the reply card and the results of the additional method suggested a higher percentage smokers among the non-respondents but this was only significant with reply card method. In general, differences between highly/less cooperative families and complete/incomplete DZ twins were small. Results suggest that, even for studies with moderate response rates, data collected on health, personality and lifestyle are relatively unbiased
Ketone body 3-hydroxybutyrate as a biomarker of aggression
Human aggression is a complex behaviour, the biological underpinnings of which remain poorly known. To gain insights into aggression biology, we studied relationships with aggression of 11 low-molecular-weight metabolites (amino acids, ketone bodies), processed using H-1 nuclear magnetic resonance spectroscopy. We used a discovery sample of young adults and an independent adult replication sample. We studied 725 young adults from a population-based Finnish twin cohort born 1983-1987, with aggression levels rated in adolescence (ages 12, 14, 17) by multiple raters and blood plasma samples at age 22. Linear regression models specified metabolites as the response variable and aggression ratings as predictor variables, and included several potential confounders. All metabolites showed low correlations with aggression, with only one-3-hydroxybutyrate, a ketone body produced during fasting-showing significant (negative) associations with aggression. Effect sizes for different raters were generally similar in magnitude, while teacher-rated (age 12) and self-rated (age 14) aggression were both significant predictors of 3-hydroxybutyrate in multi-rater models. In an independent replication sample of 960 adults from the Netherlands Twin Register, higher aggression (self-rated) was also related to lower levels of 3-hydroxybutyrate. These exploratory epidemiologic results warrant further studies on the role of ketone metabolism in aggression.Peer reviewe
Vertical and lateral manipulation of single Cs atoms on the semiconductor InAs(111)A
The tip of the scanning tunneling microscope can be used to position atoms and molecules on surfaces with atomic scale precision. Here, we report the controlled vertical and lateral manipulation of single Cs atoms on the InAs(111)A surface. The Cs adatom adsorbs on the In-vacancy site of the InAs(111)A—(2x2) surface reconstruction. Lateral manipulation is possible in all directions over the surface, not just along high-symmetry directions. Both pushing and pulling modes were observed in the height profile of the tip. We assembled two artificial structures, demonstrating the reliability of the manipulation procedures. Structures remained intact to a temperature of at least 44 K
Assessment of the serial changes of vessel wall contents in atherosclerotic coronary lesion with bioresorbable everolimus-eluting vascular scaffolds using Shin's method: an IVUS study
Although serial changes in necrotic core and calcium are regarded as surrogates for the bioresorption process in patients treated with the bioresorbable everolimus-eluting vascular scaffolds (BVS), these temporal changes have not yet been fully investigated. Shin's method may be offer a more suitable technique for this analysis because it includes all the contents of both the lumen and vessel wall. The purpose of this study was to assess the serial changes of necrotic core and dense calcium content in coronary lesions that were treated with a BVS implant using Virtual Histology intravascular ultrasound (VH-IVUS) analyzed using Shin's method. A total of 29 patients (92 coronary segments) were imaged to evaluate the serial changes in necrotic core and dense calcium using Shin's method. Lesions treated with a BVS implant were analyzed with serial VH-IVUS assessments, i.e., pre- and post-stenting, and at 6 months and 2 years follow-up. In Shin's method contours are drawn around the IVUS catheter (instead of delineating the lumen) and the vessel. The mean necrotic core area decreased by 6.9% from post-stenting to 6 months (1.71 ± 1.03 mm2vs. 1.36 ± 0.91 mm2, P = 0.027), and by 20.5% (1.71 ± 1.03 mm2vs. 1.20 ± 0.70 mm2, P = 0.003) from post-steting to 2 years; while the mean dense calcium areas decreased by 27.2% (1.07 ± 0.55 mm2vs. 0.78 ± 0.64 mm2, P = 0.039) from post-stenting and 2 years. At 2 years, absolute necrotic core and dense calcium content were significantly decreased as compared to post-stenting values. The present study demonstrates that the bioresorption process in patients who undergoing BVS device implantation can be assessed using VH-IVUS analysed using Shin's method
- …