257 research outputs found

    In Government We Trust: The Role of Fiscal Decentralization

    Get PDF
    We measure the contribution of fiscal decentralization to trust in government. Using repeated cross-country survey data of individuals on several measures of trust in government over the 1994-2007 period, we estimate an ordered response model of the government trust and fiscal decentralization nexus. We control for unobserved country characteristics, macroeconomic determinants, and individual characteristics. Our main finding is that fiscal decentralization increases trust in government. More specifically, a one percentage point increase in fiscal decentralization causes roughly a four-fifths of a percentage point increase in government trust. The beneficial effect of fiscal decentralization on trust in government is neither limited to nor necessarily large for relatively decentralized countries

    Two decades after coronary radiation therapy: A single center longitudinal clinical study

    Get PDF
    Objectives: The aim of this study was to evaluate the very long-term clinical outcome after radioactive stent (RS) implantation and intracoronary β radiation brachytherapy (IRBT). Background: Radioactive stents (RS) and intracoronary β radiation brachytherapy (IRBT) were introduced to prevent restenosis after percutaneous coronary intervention (PCI). Both techniques were associated with a higher incidence of major adverse cardiac events (MACE) in the short and intermediate-term follow up as compared to conventional PCI. Methods: One hundred and thirty-three patients received radioactive stents (32P) and 301 patients were treated with IRBT adjunctive to PCI. These groups were propensity matched to respectively 266 and 602 control patients who were treated with routine PCI during the same inclusion period. Endpoints were all-cause mortality and MACE, defined as all-cause death, any myocardial infarction or any revascularization. Results: Median follow-up duration was 17 years. All-cause mortality rates were similar in all groups. Adjusted hazard ratios for MACE and mortality in the RS cohort were 1.55 (95% CI 1.20–2.00) and 0.92 (95% CI 0.63–1.34), respectively. Adjusted hazard ratios for MACE and all-cause mortality in the IRBT cohort were 1.41 (95% CI 1.18–1.67) and 0.95 (95% CI 0.74–1.21), respectively. The difference in MACE rates was predominantly driven by coronary revascularizations in both groups, with a higher MI rate in the IRBT group as well. Conclusions: Coronary radiation therapy was associated with early increased MACE rates, but the difference in MACE rates decreased beyond 2 years, resulting in a comparable long-term clinical outcome. Importantly, no excess in mortality was observed

    Intracoronary Heparin Delivery in Humans

    Get PDF
    Background Inefficacy of systemic drug administration for restenosis prevention may partially relate to insufficient local drug concentration. This study aimed to evaluate the acute feasibility and long-term outcome of using an infusion-perfusion coil balloon, Dispatch. Methods and Results In 22 patients after balloon angioplasty, the coil balloon was studied for (1) feasibility of local heparin delivery, (2) symptoms and signs of ischemia during prolonged deployment compared with angioplasty balloon occlusion, (3) coronary pressure and flow distal to the inflated device, and (4) long-term clinical and angiographic results. During prolonged intracoronary deployment of the coil balloon (29±8 minutes), 5 of 22 patients developed mild chest pain versus 20 of 22 during angioplasty (275±283 seconds). Neither hemodynamic nor vectorcardiographic signs of ischemia were detected, in contrast to angioplasty balloon occlusion. Baseline flow across the coil balloon was 44±31 mL/min, increasing by a factor of 1.8±0.7 during pharmacologically induced hyperemia. A mean volume of 14.2±6.1 mL containing 1416±608 IU of heparin was infused locally at a pressure of 122±54 mm Hg. At 7±1-month follow-up, 1 asymptomatic patient had died, and of the remaining 21, 17 (81%) were asymptomatic. Angiographic follow-up was obtained in 15 of 21 patients (71%), including all 4 symptomatic patients. Mean minimal luminal diameter after the procedure was 2.16±0.49 mm and at follow-up, 1.89±0.45 mm, which corresponds to a restenosis rate (diameter stenosis 50%) of 7% (1/15). Conclusions Intracoronary use of the coil balloon after balloon angioplasty proved to be feasible and subjectively as well as objectively well tolerated during prolonged deployment by virtue of its perfusion properties. High volumes of heparin solution can be infused locally at very low pressure. No unfavorable clinical or angiographic long-term effects were observed
    corecore